Preventing coronary occlusion with a retrievable aortic valve
Prevenção da oclusão coronária com uma válvula aórtica recuperável
Visitas
5666
Raul Morenoa,
Autor para correspondência
raulmorenog@hotmail.com

Corresponding author.
, Maria del Carmen Monederoa, Santiago Jiménez-Valeroa, Luis Calvo Orbea, Jean Claude Labordeb, José Luis López-Sendóna
a Hospital La Paz, Madrid, Spain
b St George's Hospital, London, England, United Kingdom
Este item recebeu

Under a Creative Commons license
Informação do artigo
Texto Completo
Baixar PDF
Estatísticas
Figuras (3)
Mostrar maisMostrar menos
Texto Completo

Coronary occlusion is one of the potential complications during transcatheter aortic valve implantation. Second-generation fully retrievable and repositionable devices can theoretically prevent this complication.

A 81-year-old woman with symptomatic aortic stenosis (valve area 0.52 cm2; peak and mean gradients 118 and 70 mmHg, respectively; normal ejection fraction) was referred for transcatheter aortic valve implantation. Although her surgical risk was acceptable (logistic euroSCORE 8%), open surgery was rejected due to porcelain aorta. Preprocedural assessment included coronary angiography (normal coronary arteries) and cardiac computed tomography (aortic annulus 21 mm).

A 23 mm Lotus device (Boston Scientific) was implanted. After an 18 F sheath was advanced through the right femoral artery, percutaneous aortic valvuloplasty was performed using an 18 mm balloon and a Safari guidewire. The delivery system and the unexpanded valve were advanced retrogradely to the left ventricular cavity (Figure 1A) and manually controlled expansion of the valve was performed (Figure 1B).

Figure 1.

(A) Delivery system containing the unexpanded Lotus valve through the aortic valve; (B) the Lotus valve partially expanded.

(0.15MB).

After complete expansion of the valve, the aortic angiogram showed apparent occlusion of the left main due to the slightly high position of the valve (Figure 2A). Due to the possibility of resheathing the Lotus device even after it had been completely expanded, the valve was retrieved and repositioned in a lower position, without compromising the left main (Figure 2B), thus allowing final release of the valve (Figure 3).

Figure 2.

(A) The Lotus valve completely expanded, but not delivered. Contrast aortography shows that the valve, not yet released, is compromising the origin of the left main; (B) after the valve is resheathed and positioned at a lower level, the left main is no longer compromised.

(0.14MB).
Figure 3.

Lotus valve after final release.

(0.12MB).

This case illustrates the potential advantages of second-generation devices for transcatheter aortic valve implantation. With the Lotus device, retrieval and repositioning are possible even when the valve has been completely expanded and positioned.

Ethical disclosuresProtection of human and animal subjects

The authors declare that no experiments were performed on humans or animals for this study.

Confidentiality of data

The authors declare that no patient data appear in this article.

Right to privacy and informed consent

The authors declare that no patient data appear in this article.

Copyright © 2014. Sociedade Portuguesa de Cardiologia
Baixar PDF
Idiomas
Revista Portuguesa de Cardiologia
Opções de artigo
Ferramentas
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Ao assinalar que é «Profissional de Saúde», declara conhecer e aceitar que a responsável pelo tratamento dos dados pessoais dos utilizadores da página de internet da Revista Portuguesa de Cardiologia (RPC), é esta entidade, com sede no Campo Grande, n.º 28, 13.º, 1700-093 Lisboa, com os telefones 217 970 685 e 217 817 630, fax 217 931 095 e com o endereço de correio eletrónico revista@spc.pt. Declaro para todos os fins, que assumo inteira responsabilidade pela veracidade e exatidão da afirmação aqui fornecida.