Informação da revista
Vol. 32. Núm. 9.
Páginas 737-739 (Setembro 2013)
Vol. 32. Núm. 9.
Páginas 737-739 (Setembro 2013)
Image in Cardiology
Open Access
Repaired acute type A aortic dissection: Case closed?
Dissecção aórtica tipo A aguda corrigida: caso encerrado?
Visitas
7461
Francisca Caetanoa,
Autor para correspondência
franciscacaetano@sapo.pt

Corresponding author.
, Andreia Fernandesa, Joana Trigoa, Susana Bassob, Ana Botelhoa, António Leitão Marquesa
a Serviço de Cardiologia, Centro Hospitalar e Universitário de Coimbra, Hospital Geral, Coimbra, Portugal
b Serviço de Radiologia, Centro Hospitalar e Universitário de Coimbra, Hospital Geral, Coimbra, Portugal
Este item recebeu

Under a Creative Commons license
Informação do artigo
Texto Completo
Baixar PDF
Estatísticas
Figuras (4)
Mostrar maisMostrar menos
Texto Completo

Acute type A aortic dissection is a surgical emergency, and the development of false aneurysms is one reason for reoperation.

An 82-year-old man went to the emergency department with oppressive chest pain radiating to the back for three weeks and symptoms of heart failure, in NYHA class III/IV. He had a history of acute type A aortic dissection and had had a Dacron tube graft implanted at the age of 64.

The transthoracic echocardiogram (Figure 1) showed the Dacron graft in the ascending aorta and an apparent solution of continuity in the proximal portion of the anastomosis, a large aneurysm (53 mm × 71 mm) with thrombus compressing the pulmonary artery trunk (peak gradient 27 mmHg), and moderate to severe aortic regurgitation.

Figure 1.

Transthoracic echocardiogram showing the Dacron tube graft in the ascending aorta (blue diamond) and a large aneurysm (53 mm × 71 mm) with thrombus (red diamond) and flow apparently originating from the proximal and distal ends of the tube.

Thoracic computed tomography angiography (Figures 2 and 3) showed the Dacron tube from 2.1 cm above the aortic valve leaflets to 1.8 cm after the emergence of the brachiocephalic trunk surrounded by an image suggestive of an ascending aortic aneurysm (10 cm × 10 cm) with two active contrast leaks at the ends of the graft (type 1 endoleak), compressing the right ventricle, pulmonary artery trunk and right coronary artery.

Figure 2.

Thoracic computed tomography angiography showing contrast flow (red diamond) due to a proximal leak from the Dacron tube (purple diamond) and a large ascending aorta aneurysm with organized thrombus (blue diamond) compressing the pulmonary artery trunk (green diamond).

Figure 3.

Thoracic computed tomography angiography showing contrast flow (red diamond) due to a distal leak from the Dacron tube (red diamond) (type 1 endoleak).

Aortography (Figure 4) revealed an apparent proximal leak in the Dacron tube and a false lumen forming a large saccular aneurysm.

Figure 4.

Aortography showing false lumen forming a large saccular aneurysm (red diamond).

Following joint medical and surgical evaluation, it was decided that the patient was unsuitable for cardiac surgery due to his multiple comorbidities (chronic obstructive pulmonary disease, obstructive sleep apnea syndrome and chronic renal failure), which was also in agreement with his and his family's wishes. He was discharged in NYHA class II–III/IV.

The patient was readmitted four months later due to heart failure and died from a nosocomial infection.

Conflicts of interest

The authors have no conflicts of interest to declare.

Please cite this article as: Caetano F, Fernandes A, Trigo J, Basso S, Botelho A, Leitão Marques A. Dissecção aórtica tipo A aguda corrigida: caso encerrado? Rev Port Cardiol. 2013;32:737–739.

Copyright © 2013. Sociedade Portuguesa de Cardiologia
Baixar PDF
Idiomas
Revista Portuguesa de Cardiologia
Opções de artigo
Ferramentas
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Ao assinalar que é «Profissional de Saúde», declara conhecer e aceitar que a responsável pelo tratamento dos dados pessoais dos utilizadores da página de internet da Revista Portuguesa de Cardiologia (RPC), é esta entidade, com sede no Campo Grande, n.º 28, 13.º, 1700-093 Lisboa, com os telefones 217 970 685 e 217 817 630, fax 217 931 095 e com o endereço de correio eletrónico revista@spc.pt. Declaro para todos os fins, que assumo inteira responsabilidade pela veracidade e exatidão da afirmação aqui fornecida.