array:25 [
  "pii" => "S0870255121002511"
  "issn" => "08702551"
  "doi" => "10.1016/j.repc.2021.06.006"
  "estado" => "S300"
  "fechaPublicacion" => "2021-08-01"
  "aid" => "1768"
  "copyright" => "Sociedade Portuguesa de Cardiologia"
  "copyrightAnyo" => "2021"
  "documento" => "simple-article"
  "crossmark" => 1
  "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
  "subdocumento" => "dis"
  "cita" => "Rev Port Cardiol. 2021;40:569-71"
  "abierto" => array:3 [
    "ES" => true
    "ES2" => true
    "LATM" => true
  ]
  "gratuito" => true
  "lecturas" => array:1 [
    "total" => 0
  ]
  "Traduccion" => array:1 [
    "en" => array:20 [
      "pii" => "S2174204921002154"
      "issn" => "21742049"
      "doi" => "10.1016/j.repce.2021.07.027"
      "estado" => "S300"
      "fechaPublicacion" => "2021-08-01"
      "aid" => "1768"
      "copyright" => "Sociedade Portuguesa de Cardiologia"
      "documento" => "simple-article"
      "crossmark" => 0
      "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
      "subdocumento" => "dis"
      "cita" => "Rev Port Cardiol. 2021;40:569-71"
      "abierto" => array:3 [
        "ES" => true
        "ES2" => true
        "LATM" => true
      ]
      "gratuito" => true
      "lecturas" => array:1 [
        "total" => 0
      ]
      "en" => array:10 [
        "idiomaDefecto" => true
        "cabecera" => "<span class="elsevierStyleTextfn">Editorial comment</span>"
        "titulo" => "Percutaneous closure of patent ductus arteriosus&#58; A standard procedure with new perspectives"
        "tienePdf" => "en"
        "tieneTextoCompleto" => "en"
        "paginas" => array:1 [
          0 => array:2 [
            "paginaInicial" => "569"
            "paginaFinal" => "571"
          ]
        ]
        "titulosAlternativos" => array:1 [
          "pt" => array:1 [
            "titulo" => "Encerramento percut&#226;neo de canal arterial persistente&#58; um procedimento padr&#227;o com novas perspetivas"
          ]
        ]
        "contieneTextoCompleto" => array:1 [
          "en" => true
        ]
        "contienePdf" => array:1 [
          "en" => true
        ]
        "autores" => array:1 [
          0 => array:2 [
            "autoresLista" => "F&#225;tima F&#46; Pinto"
            "autores" => array:1 [
              0 => array:2 [
                "nombre" => "F&#225;tima F&#46;"
                "apellidos" => "Pinto"
              ]
            ]
          ]
        ]
      ]
      "idiomaDefecto" => "en"
      "Traduccion" => array:1 [
        "en" => array:9 [
          "pii" => "S0870255121002511"
          "doi" => "10.1016/j.repc.2021.06.006"
          "estado" => "S300"
          "subdocumento" => ""
          "abierto" => array:3 [
            "ES" => true
            "ES2" => true
            "LATM" => true
          ]
          "gratuito" => true
          "lecturas" => array:1 [
            "total" => 0
          ]
          "idiomaDefecto" => "en"
          "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0870255121002511?idApp=UINPBA00004E"
        ]
      ]
      "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204921002154?idApp=UINPBA00004E"
      "url" => "/21742049/0000004000000008/v1_202108130730/S2174204921002154/v1_202108130730/en/main.assets"
    ]
  ]
  "itemSiguiente" => array:20 [
    "pii" => "S0870255121001049"
    "issn" => "08702551"
    "doi" => "10.1016/j.repc.2020.11.007"
    "estado" => "S300"
    "fechaPublicacion" => "2021-08-01"
    "aid" => "1714"
    "copyright" => "Sociedade Portuguesa de Cardiologia"
    "documento" => "article"
    "crossmark" => 1
    "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
    "subdocumento" => "fla"
    "cita" => "Rev Port Cardiol. 2021;40:573-80"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:1 [
      "total" => 0
    ]
    "en" => array:13 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Original Article</span>"
      "titulo" => "Cardiac arrhythmias in patients presenting with COVID-19 treated in Portuguese hospitals&#58; A national registry from the Portuguese Association of Arrhythmology&#44; Pacing and Electrophysiology"
      "tienePdf" => "en"
      "tieneTextoCompleto" => "en"
      "tieneResumen" => array:2 [
        0 => "en"
        1 => "pt"
      ]
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "573"
          "paginaFinal" => "580"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "pt" => array:1 [
          "titulo" => "Arritmias card&#237;acas em doentes com COVID-19 tratados em hospitais portugueses&#46; Um registo nacional da APAPE"
        ]
      ]
      "contieneResumen" => array:2 [
        "en" => true
        "pt" => true
      ]
      "contieneTextoCompleto" => array:1 [
        "en" => true
      ]
      "contienePdf" => array:1 [
        "en" => true
      ]
      "resumenGrafico" => array:2 [
        "original" => 0
        "multimedia" => array:7 [
          "identificador" => "fig0010"
          "etiqueta" => "Figure 2"
          "tipo" => "MULTIMEDIAFIGURA"
          "mostrarFloat" => true
          "mostrarDisplay" => false
          "figura" => array:1 [
            0 => array:4 [
              "imagen" => "gr2.jpeg"
              "Alto" => 2569
              "Ancho" => 1508
              "Tamanyo" => 417998
            ]
          ]
          "descripcion" => array:1 [
            "en" => "<p id="spar0050" class="elsevierStyleSimplePara elsevierViewall">Electronic questionnaire for patients with arrhythmic episodes used in the survey&#46;</p>"
          ]
        ]
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "Dinis Mesquita, Pedro Carmo, Nuno Cabanelas, Nuno Santos, V&#237;tor Martins, Victor Sanfins, Helena Cristina Costa, Jos&#233; Paulo Fontes, Paulo Fonseca, Leonor Parreira"
          "autores" => array:11 [
            0 => array:2 [
              "nombre" => "Dinis"
              "apellidos" => "Mesquita"
            ]
            1 => array:2 [
              "nombre" => "Pedro"
              "apellidos" => "Carmo"
            ]
            2 => array:2 [
              "nombre" => "Nuno"
              "apellidos" => "Cabanelas"
            ]
            3 => array:2 [
              "nombre" => "Nuno"
              "apellidos" => "Santos"
            ]
            4 => array:2 [
              "nombre" => "V&#237;tor"
              "apellidos" => "Martins"
            ]
            5 => array:2 [
              "nombre" => "Victor"
              "apellidos" => "Sanfins"
            ]
            6 => array:2 [
              "nombre" => "Helena Cristina"
              "apellidos" => "Costa"
            ]
            7 => array:2 [
              "nombre" => "Jos&#233; Paulo"
              "apellidos" => "Fontes"
            ]
            8 => array:2 [
              "nombre" => "Paulo"
              "apellidos" => "Fonseca"
            ]
            9 => array:2 [
              "nombre" => "Leonor"
              "apellidos" => "Parreira"
            ]
            10 => array:1 [
              "colaborador" => "on behalf of the Portuguese Association of Arrhythmology&#44; Pacing and Electrophysiology &#40;APAPE&#41;"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "en"
    "Traduccion" => array:1 [
      "en" => array:9 [
        "pii" => "S2174204921002166"
        "doi" => "10.1016/j.repce.2020.11.025"
        "estado" => "S300"
        "subdocumento" => ""
        "abierto" => array:3 [
          "ES" => true
          "ES2" => true
          "LATM" => true
        ]
        "gratuito" => true
        "lecturas" => array:1 [
          "total" => 0
        ]
        "idiomaDefecto" => "en"
        "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204921002166?idApp=UINPBA00004E"
      ]
    ]
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0870255121001049?idApp=UINPBA00004E"
    "url" => "/08702551/0000004000000008/v1_202108010531/S0870255121001049/v1_202108010531/en/main.assets"
  ]
  "itemAnterior" => array:20 [
    "pii" => "S0870255121001700"
    "issn" => "08702551"
    "doi" => "10.1016/j.repc.2020.09.008"
    "estado" => "S300"
    "fechaPublicacion" => "2021-08-01"
    "aid" => "1734"
    "copyright" => "Sociedade Portuguesa de Cardiologia"
    "documento" => "article"
    "crossmark" => 1
    "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
    "subdocumento" => "fla"
    "cita" => "Rev Port Cardiol. 2021;40:561-8"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:1 [
      "total" => 0
    ]
    "en" => array:13 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Original Article</span>"
      "titulo" => "Percutaneous patent ductus arteriosus closure&#58; Twelve years of experience"
      "tienePdf" => "en"
      "tieneTextoCompleto" => "en"
      "tieneResumen" => array:2 [
        0 => "en"
        1 => "pt"
      ]
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "561"
          "paginaFinal" => "568"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "pt" => array:1 [
          "titulo" => "Encerramento percut&#226;neo de canal arterial persistente&#58; doze anos de experi&#234;ncia"
        ]
      ]
      "contieneResumen" => array:2 [
        "en" => true
        "pt" => true
      ]
      "contieneTextoCompleto" => array:1 [
        "en" => true
      ]
      "contienePdf" => array:1 [
        "en" => true
      ]
      "resumenGrafico" => array:2 [
        "original" => 0
        "multimedia" => array:7 [
          "identificador" => "fig0035"
          "etiqueta" => "Figure 7"
          "tipo" => "MULTIMEDIAFIGURA"
          "mostrarFloat" => true
          "mostrarDisplay" => false
          "figura" => array:1 [
            0 => array:4 [
              "imagen" => "gr7.jpeg"
              "Alto" => 586
              "Ancho" => 1255
              "Tamanyo" => 82184
            ]
          ]
          "descripcion" => array:1 [
            "en" => "<p id="spar0090" class="elsevierStyleSimplePara elsevierViewall">Pre &#40;A&#41; and post-closure &#40;B&#41; lateral aortography depicting a patent ductus arteriosus occlusion with a 5x6 mm ADO II AS device&#46;</p> <p id="spar0095" class="elsevierStyleSimplePara elsevierViewall">ADO&#58; Amplatzer duct occluder&#59; AS&#58; additional sizes&#46;</p>"
          ]
        ]
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "Jo&#227;o Antunes Sarmento, Ana Correia-Costa, Edite Gon&#231;alves, Maria Jo&#227;o Baptista, Jo&#227;o Carlos Silva, Jorge Moreira"
          "autores" => array:6 [
            0 => array:2 [
              "nombre" => "Jo&#227;o"
              "apellidos" => "Antunes Sarmento"
            ]
            1 => array:2 [
              "nombre" => "Ana"
              "apellidos" => "Correia-Costa"
            ]
            2 => array:2 [
              "nombre" => "Edite"
              "apellidos" => "Gon&#231;alves"
            ]
            3 => array:2 [
              "nombre" => "Maria Jo&#227;o"
              "apellidos" => "Baptista"
            ]
            4 => array:2 [
              "nombre" => "Jo&#227;o Carlos"
              "apellidos" => "Silva"
            ]
            5 => array:2 [
              "nombre" => "Jorge"
              "apellidos" => "Moreira"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "en"
    "Traduccion" => array:1 [
      "en" => array:9 [
        "pii" => "S2174204921002142"
        "doi" => "10.1016/j.repce.2020.09.009"
        "estado" => "S300"
        "subdocumento" => ""
        "abierto" => array:3 [
          "ES" => true
          "ES2" => true
          "LATM" => true
        ]
        "gratuito" => true
        "lecturas" => array:1 [
          "total" => 0
        ]
        "idiomaDefecto" => "en"
        "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204921002142?idApp=UINPBA00004E"
      ]
    ]
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0870255121001700?idApp=UINPBA00004E"
    "url" => "/08702551/0000004000000008/v1_202108010531/S0870255121001700/v1_202108010531/en/main.assets"
  ]
  "en" => array:12 [
    "idiomaDefecto" => true
    "cabecera" => "<span class="elsevierStyleTextfn">Editorial comment</span>"
    "titulo" => "Percutaneous closure of patent ductus arteriosus&#58; A standard procedure with new perspectives"
    "tieneTextoCompleto" => true
    "paginas" => array:1 [
      0 => array:2 [
        "paginaInicial" => "569"
        "paginaFinal" => "571"
      ]
    ]
    "autores" => array:1 [
      0 => array:3 [
        "autoresLista" => "F&#225;tima F&#46; Pinto"
        "autores" => array:1 [
          0 => array:3 [
            "nombre" => "F&#225;tima F&#46;"
            "apellidos" => "Pinto"
            "email" => array:1 [
              0 => "fatima.pinto@chlc.min-saude.pt"
            ]
          ]
        ]
        "afiliaciones" => array:1 [
          0 => array:2 [
            "entidad" => "Universidade NOVA de Lisboa&#44; Servi&#231;o de Cardiologia Pedi&#225;trica&#44; Centro de Refer&#234;ncia de Cardiopatias Cong&#233;nitas&#44; CHULC&#44; EPE &#8211; Hospital de Santa Marta&#44; Portugal"
            "identificador" => "aff0005"
          ]
        ]
      ]
    ]
    "titulosAlternativos" => array:1 [
      "pt" => array:1 [
        "titulo" => "Encerramento percut&#226;neo de canal arterial persistente&#58; um procedimento padr&#227;o com novas perspetivas"
      ]
    ]
    "textoCompleto" => "<span class="elsevierStyleSections"><p id="par0005" class="elsevierStylePara elsevierViewall">Patent ductus arteriosus &#40;PDA&#41; is one of the most frequent congenital heart defects and may occur as an isolated lesion or in association with others&#46; Its incidence varies from 5&#37; to 10&#37; of all congenital heart disease in term infants&#44;<a class="elsevierStyleCrossRef" href="#bib0150"><span class="elsevierStyleSup">1</span></a> increasing to 20&#37; to 60&#37; in preterm neonates&#46; This is attributable to the lack of normal closure mechanisms due to immaturity in the premature neonate&#46;<a class="elsevierStyleCrossRef" href="#bib0155"><span class="elsevierStyleSup">2</span></a> Most patients have a small to moderate PDA causing restrictive flow with small left-to-right shunt&#44; presenting as symptom-free or with few symptoms&#46; The natural history of these lesions would probably be uneventful&#44; except for the risk of infective endocarditis&#46; Moderate to large PDA will cause an unrestrictive flow&#44; with potential for congestive heart failure &#40;HF&#41; and pulmonary vascular disease&#46; The rational for PDA closure is to prevent late complications such as canaliculitis&#44; HF or Eisenmenger syndrome in late age&#46; Exceptions are neonate or preterm infants with large PDA and the presence of severe pulmonary hypertension&#46;</p><p id="par0010" class="elsevierStylePara elsevierViewall">Since the first successful reports of surgical treatment of a PDA&#44; by Gross and Hubbard in 1939&#44;<a class="elsevierStyleCrossRef" href="#bib0160"><span class="elsevierStyleSup">3</span></a> surgical technique&#8212;either ligation of division&#8212;has been widely used for large and symptomatic PDA&#46; Although it has been shown that surgery is safe and effective with only occasional complications and some cases of recanalization&#44; pediatric cardiologists have always tried to develop a transcatheter method to close PDA and other anomalies&#46;</p><p id="par0015" class="elsevierStylePara elsevierViewall">The first report on non-surgical closure was by Portsmann et al&#46; in 1967&#46;<a class="elsevierStyleCrossRef" href="#bib0165"><span class="elsevierStyleSup">4</span></a> This investigator along with Rashkind et al&#46;<a class="elsevierStyleCrossRef" href="#bib0170"><span class="elsevierStyleSup">5</span></a> pioneered the development of several PDA closure devices&#46; Due to their efforts&#44; PDA percutaneous occlusion became an effective and safe procedure&#44; and is nowadays the standard method for PDA closure&#46;</p><p id="par0020" class="elsevierStylePara elsevierViewall">After these initial devices&#44; various types of occlusion systems have been developed&#46; Gianturco&#44; Jackson coils &#40;both free and detachable&#41; and similar devices have become an established method for PDA transcatheter closure&#46;<a class="elsevierStyleCrossRefs" href="#bib0175"><span class="elsevierStyleSup">6&#8211;9</span></a> Since 1992&#44; coils have evolved into the most commonly used devices for small-sized PDA occlusion&#46; The introduction of the Amplatzer&#174; duct occluder family &#40;ADO&#44; Abbott&#44; USA&#41; in 2001&#44; changed the perspective on this procedure&#44; because of increased safety characteristics&#44; like retrievability&#44; repositioning and also the possibility to close defects up to 16 mm in diameter&#46; They are among the most frequently used occluders for large and moderate PDA occlusion&#46;<a class="elsevierStyleCrossRefs" href="#bib0195"><span class="elsevierStyleSup">10&#8211;12</span></a> Another recent device is the Nit-Occlud&#174; &#40;NOc&#44; pfm&#44; Germany&#41; coil&#44; which was designed specifically for PDA closure&#46; This coil has undergone several modifications since it was first developed&#44; with the latest version in use since 2001&#46;<a class="elsevierStyleCrossRefs" href="#bib0210"><span class="elsevierStyleSup">13&#44;14</span></a> Procedures using these techniques were reported to be safe and effective&#44; and although complications occur&#44; critical complications are rare&#46;<a class="elsevierStyleCrossRefs" href="#bib0175"><span class="elsevierStyleSup">6&#8211;14</span></a> Device embolization&#44; the most feared complication&#44; was relatively common in early experience with coils but became rare with the new generation of devices&#46; Reported occlusion rates vary according to operator experience&#44; and post procedure period&#44; from 41&#37; immediately after the procedure to 95 to 100&#37; at three months of follow up&#46;<a class="elsevierStyleCrossRefs" href="#bib0220"><span class="elsevierStyleSup">15&#8211;18</span></a> Nevertheless&#44; several studies have demonstrated that intermediate and long-term outcomes of percutaneous PDA occlusion with current devices are excellent&#46;<a class="elsevierStyleCrossRefs" href="#bib0230"><span class="elsevierStyleSup">17&#8211;19</span></a></p><p id="par0025" class="elsevierStylePara elsevierViewall">In the present study&#44; Sarmento et al&#46;<a class="elsevierStyleCrossRef" href="#bib0245"><span class="elsevierStyleSup">20</span></a> present the results with percutaneous PDA occlusion from a single center for twelve years using at least three different devices&#46; The authors claim to report one of the largest series using the PDA NOc devices&#44; which adds value to the study&#46; In their series&#44; the immediate procedural occlusion rate&#44; assessed by angiography&#44; was high &#40;98&#46;6&#37;&#41;&#44; with a low complication rate &#40;1&#46;8&#37;&#41;&#44; and a single case of embolization&#44; in line with other reported data&#46;<a class="elsevierStyleCrossRefs" href="#bib0195"><span class="elsevierStyleSup">10&#44;21</span></a> The success rate was associated with vascular accessibility&#44; morphology of the ductus&#44; imaging modality&#44; and adequate selection of the device&#46; The study adds no novelty to the technique&#44; but reports on an important case experience at national level&#46; However&#44; the authors fail to explain the set for &#8220;adequate selection of device&#8221; and the criteria for performing coil&#47;device closure&#46; Also&#44; regarding the results&#44; the reported occlusion rate refers to the immediate result&#44; assessed by aortography&#46; The study would be more robust if the authors had described the immediate or 24-hour occlusion rate assessed by echocardiography&#44; which would enable a more accurate assessment and long-term outcomes&#44; as we would expect from a twelve-year retrospective study&#46; Despite these limitations&#44; the study is of value and it gives us the opportunity to discuss issues germane to transcatheter PDA closure&#44; such as indications&#44; selection of devices&#44; expected results and future perspectives&#46;</p><p id="par0030" class="elsevierStylePara elsevierViewall">Percutaneous PDA occlusion is indicated for lesions presenting with suggestive continuous murmur&#44; confirmed by echocardiography&#46; Ductus with absence of these typical findings&#44; so-called &#8216;silent ductus&#8217;&#44; should not be occluded&#44; although controversy exists with some authors recommending occlusion&#46;<a class="elsevierStyleCrossRef" href="#bib0255"><span class="elsevierStyleSup">22</span></a> Small size PDA without significant left ventricle overflow should be treated to prevent infective endocarditis&#46; Medium and large size defects&#44; which present significant left-to-right shunt&#44; are treated to prevent HF and pulmonary vascular occlusive disease&#46;</p><p id="par0035" class="elsevierStylePara elsevierViewall">Adequate patient age and size have been an issue&#44; and indications have evolved over time and with new and innovative PDA occluding devices&#46; Until recently&#44; transcatheter PDA closure was considered the procedure of choice for infants &#8805;6 kg and adults&#46; Although an exact lower weight limit has not been set for a safe occlusion&#44; only a few studies have reported results in neonates and infants below this weight threshold&#46;<a class="elsevierStyleCrossRefs" href="#bib0260"><span class="elsevierStyleSup">23&#8211;25</span></a> Recently&#44; these limits have been exceeded with the release of the new miniaturized devices adequate for premature infants under 1&#46;5 kg&#46; There is an ongoing prospective trial to compare the classic surgical approach to percutaneous PDA occlusion in preterm infants over 700 g and three days old&#44; using the Amplatzer&#174; Piccolo Occluder&#44; an evolution of the Amplatzer&#174; additional sizes &#40;ADO AS&#41; family devices&#46;<a class="elsevierStyleCrossRef" href="#bib0275"><span class="elsevierStyleSup">26</span></a> These advances&#44; although with promising early and mid-term results&#44; need to be confirmed in randomized controlled trials before they can become a standard of care&#46;</p><p id="par0040" class="elsevierStylePara elsevierViewall">Patent ductus arteriosus is an uncommon anomaly in adults&#44; but in this age group they present several pathological changes&#44; such as tortuosity&#44; calcification&#44; friability&#44; aneurysm formation and ductal shortening&#46;<a class="elsevierStyleCrossRef" href="#bib0280"><span class="elsevierStyleSup">27</span></a> A calcified duct is more fragile and difficult to cross and the treatment option was surgery with cardiopulmonary bypass&#44; to overcome complexity and complications&#46; However&#44; the development of new occlusion devices that can be deployed on the arterial side have enabled percutaneous occlusion in adult patients&#46;<a class="elsevierStyleCrossRefs" href="#bib0285"><span class="elsevierStyleSup">28&#44;29</span></a> Treatment selection must&#44; however&#44; be made on an individual bases&#44; especially in heavily calcified and fragile ducts&#46; Although there are no specific guidelines for device selection&#44; it seems logical that a less rigid device such as ADO II&#44; ADO II AS&#44; vascular plugs and PDA NOc would cause less shear stress on these fragile walls&#46;</p><p id="par0045" class="elsevierStylePara elsevierViewall">Based on personal experience&#44;<a class="elsevierStyleCrossRefs" href="#bib0190"><span class="elsevierStyleSup">9&#44;12</span></a> most PDA can be occluded using a percutaneous approach&#44; keeping in mind that the selection of patients and devices remains the major factor for success and effectiveness&#44; so it is important to take into account patient characteristics&#44; PDA shape&#44; size and minimal diameter&#46; Small to very-small PDA &#40;&#60;2&#46;5 and 1&#46;5 mm in diameter respectively&#44; with continuous murmur&#41; can easily be occluded&#44; regardless of their shape&#44; using detachable coils&#44; which are a cheap and effective choice&#46; Device selection for conical PDA is broader&#44; as either coils or ADO devices and similar can be used depending on the size and minimum diameter of the PDA&#46; Although there is no exact threshold&#44; the latter are usually used to occlude PDA over 2&#46;5 mm in diameter&#46; The PDA NOc devices are recommended&#44; in most studies&#44; to occlude small to moderate PDA&#44; as shown by the authors of this study report&#46; ADO devices are used with greater efficiency in ductus of a larger diameter or morphology that is unfavorable to occlusion with coils&#46;</p><p id="par0050" class="elsevierStylePara elsevierViewall">Complete PDA occlusion and absence of complications are the expected results of percutaneous PDA occlusion&#46; Residual shunting is more common with coils and when it occurs&#44; it has to be treated with repeated procedures&#44; as it may lead to endocarditis or to hemolysis&#46; Device embolization is rare and also more frequent with coils&#44; with an occurrence rate &#60;1&#37;&#46; Device-induced pulmonary branch stenosis or aortic coarctation is rarely seen&#44; although D&#246;ppler flow acceleration without invasive gradient may occur&#44; it might resolve spontaneously with growth&#46; Aortography&#44; before and after releasing the implanted device&#44; is the method selected to evaluate immediate result&#44; but echocardiography is more adequate for post-procedural assessment and quantification of incomplete occlusion and late complications&#46; We should however point out&#44; that when using coils&#44; we would recommend continuing catheterization until complete ductal closure is documented by angiography&#44; because of increased risk of embolization and hemolysis&#46; Vascular injury from the delivery system is another feared complication&#44; especially in small infants&#46; Nevertheless&#44; this is rarely seen with experienced operators&#44; also taking into account the evolution in downsizing delivery sheaths over the last five decades&#46;</p><p id="par0055" class="elsevierStylePara elsevierViewall">Finally&#44; transcatheter PDA closure stands as the standard treatment in most cases&#46; Coils and ADO devices or similar are the most frequently used closure devices worldwide&#46; This approach is feasible&#44; effective and safe with current devices and techniques leading to excellent outcomes&#46; Future perspectives foresee the evolution of techniques to address more challenging cases&#44; such as preterm and low birth weight infants and complex cases in adults&#44; with high occlusion rate and few complications&#46; During the past 50 years&#44; we have witnessed a remarkable evolution in techniques&#44; devices and delivery systems&#44; so we can only anticipate further improvements in transcatheter PDA closure&#46;</p><span id="sec0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0005">Conflicts of interest</span><p id="par0060" class="elsevierStylePara elsevierViewall">The author has no conflicts of interest to declare&#46;</p></span></span>"
    "textoCompletoSecciones" => array:1 [
      "secciones" => array:2 [
        0 => array:2 [
          "identificador" => "sec0005"
          "titulo" => "Conflicts of interest"
        ]
        1 => array:1 [
          "titulo" => "References"
        ]
      ]
    ]
    "pdfFichero" => "main.pdf"
    "tienePdf" => true
    "bibliografia" => array:2 [
      "titulo" => "References"
      "seccion" => array:1 [
        0 => array:2 [
          "identificador" => "bibs0015"
          "bibliografiaReferencia" => array:29 [
            0 => array:3 [
              "identificador" => "bib0150"
              "etiqueta" => "1"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Patent ductus arteriosus"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:2 [
                            0 => "D&#46;J&#46; Schneider"
                            1 => "J&#46;W&#46; Moore"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Circulation"
                        "fecha" => "2006"
                        "volumen" => "114"
                        "paginaInicial" => "1873"
                        "paginaFinal" => "1882"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            1 => array:3 [
              "identificador" => "bib0155"
              "etiqueta" => "2"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Severity of the ductal shunt&#58; a comparison of different markers"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "M&#46;E&#46; Hajjar"
                            1 => "G&#46; Vaksmann"
                            2 => "T&#46; Rakza"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1136/adc.2003.027698"
                      "Revista" => array:6 [
                        "tituloSerie" => "Arch Dis Child Fetal Neonatal Ed"
                        "fecha" => "2005"
                        "volumen" => "90"
                        "paginaInicial" => "F419"
                        "paginaFinal" => "F422"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/16113155"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            2 => array:3 [
              "identificador" => "bib0160"
              "etiqueta" => "3"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Surgical ligation of patent ductus arteriosus&#58; a report of first successful case"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:2 [
                            0 => "R&#46;E&#46; Gross"
                            1 => "J&#46;P&#46; Hubbard"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "J Am Med Assoc"
                        "fecha" => "1939"
                        "volumen" => "112"
                        "paginaInicial" => "729"
                        "paginaFinal" => "731"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            3 => array:3 [
              "identificador" => "bib0165"
              "etiqueta" => "4"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Closure of persistent ductus arteriosus without thoracotomy"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "W&#46; Porstmann"
                            1 => "L&#46; Wierny"
                            2 => "H&#46; Warnke"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Ger Med Mon"
                        "fecha" => "1967"
                        "volumen" => "12"
                        "paginaInicial" => "259"
                        "paginaFinal" => "261"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/6045537"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            4 => array:3 [
              "identificador" => "bib0170"
              "etiqueta" => "5"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Nonsurgical closure of patent ductus arteriosus&#58; clinical application of the Rashkind PDA Occluder System"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "W&#46;J&#46; Rashkind"
                            1 => "C&#46;E&#46; Mullins"
                            2 => "W&#46;E&#46; Hellenbrand"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Circulation"
                        "fecha" => "1987"
                        "volumen" => "75"
                        "paginaInicial" => "583"
                        "paginaFinal" => "592"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            5 => array:3 [
              "identificador" => "bib0175"
              "etiqueta" => "6"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Mechanical device for arterial occlusion"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "C&#46; Gianturco"
                            1 => "J&#46;H&#46; Anderson"
                            2 => "S&#46; Wallace"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.2214/ajr.124.3.428"
                      "Revista" => array:6 [
                        "tituloSerie" => "Am J Roentgen"
                        "fecha" => "1975"
                        "volumen" => "124"
                        "paginaInicial" => "428"
                        "paginaFinal" => "435"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/50746"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            6 => array:3 [
              "identificador" => "bib0180"
              "etiqueta" => "7"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Percutaneous closure of small &#40;&#60;2&#46;5 mm&#41; patent ductus arteriosus using coil embolization"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "P&#46;A&#46; Cambier"
                            1 => "W&#46;C&#46; Kirby"
                            2 => "D&#46;C&#46; Wortham"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/0002-9149(92)90514-y"
                      "Revista" => array:6 [
                        "tituloSerie" => "Am J Cardiol"
                        "fecha" => "1992"
                        "volumen" => "69"
                        "paginaInicial" => "815"
                        "paginaFinal" => "816"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/1546662"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            7 => array:3 [
              "identificador" => "bib0185"
              "etiqueta" => "8"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Transcatheter occlusion of patent ductus arteriosus with Cook detachable coils"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "A&#46;J&#46; Tometzki"
                            1 => "R&#46; Arnold"
                            2 => "I&#46; Peart"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1136/hrt.76.6.531"
                      "Revista" => array:6 [
                        "tituloSerie" => "Heart"
                        "fecha" => "1996"
                        "volumen" => "76"
                        "paginaInicial" => "531"
                        "paginaFinal" => "535"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/9014804"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            8 => array:3 [
              "identificador" => "bib0190"
              "etiqueta" => "9"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Oclus&#227;o do canal arterial por via percut&#226;nea com filamentos helicoidais de separa&#231;&#227;o control&#225;vel"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "S&#46; Kaku"
                            1 => "F&#46;F&#46; Pinto"
                            2 => "R&#46; Ferreira"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Rev Port Cardiol"
                        "fecha" => "1996"
                        "volumen" => "15"
                        "paginaInicial" => "913"
                        "paginaFinal" => "916"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/9052968"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            9 => array:3 [
              "identificador" => "bib0195"
              "etiqueta" => "10"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Catheter closure of moderate- to large-sized patent ductus arteriosus using the new Amplatzer duct occluder&#58; immediate and short-term results"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "J&#46; Masura"
                            1 => "K&#46;P&#46; Walsh"
                            2 => "B&#46; Thanopoulous"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/s0735-1097(98)00013-8"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Am Coll Cardiol"
                        "fecha" => "1998"
                        "volumen" => "31"
                        "paginaInicial" => "878"
                        "paginaFinal" => "882"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/9525563"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            10 => array:3 [
              "identificador" => "bib0200"
              "etiqueta" => "11"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Transcatheter closure of moderate-to-large patent ductus arteriosus in infants using Amplatzer duct occluder"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "J&#46;K&#46; Wang"
                            1 => "M&#46;H&#46; Wu"
                            2 => "M&#46;T&#46; Lin"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Circ J"
                        "fecha" => "2010"
                        "volumen" => "74"
                        "paginaInicial" => "361"
                        "paginaFinal" => "364"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            11 => array:3 [
              "identificador" => "bib0205"
              "etiqueta" => "12"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Oclus&#227;o percut&#226;nea de canal arterial persistente com o novo dispositivo de Amplatzer&#58; resultados imediatos e a m&#233;dio-prazo"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "F&#46;F&#46; Pinto"
                            1 => "trigo c"
                            2 => "G&#46; Nogueira"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Rev Port Cardiol"
                        "fecha" => "2001"
                        "volumen" => "20"
                        "numero" => "Suppl&#46; IV"
                        "paginaInicial" => "81"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            12 => array:3 [
              "identificador" => "bib0210"
              "etiqueta" => "13"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Total UK multi-centre experience with a novel arterial occlusion device &#40;Duct-Occlud pfm&#41;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "A&#46; Tometzki"
                            1 => "K&#46; Chan"
                            2 => "J&#46; De Giovanni"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1136/hrt.76.6.520"
                      "Revista" => array:6 [
                        "tituloSerie" => "Heart"
                        "fecha" => "1996"
                        "volumen" => "76"
                        "paginaInicial" => "520"
                        "paginaFinal" => "524"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/9014802"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            13 => array:3 [
              "identificador" => "bib0215"
              "etiqueta" => "14"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Duct-occlud for occlusion of patent ductus arteriosus"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "T&#46;P&#46; Le"
                            1 => "J&#46;W&#46; Moore"
                            2 => "M&#46;B&#46; Neuss"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Curr Interv Cardiol Rep"
                        "fecha" => "2001"
                        "volumen" => "3"
                        "paginaInicial" => "165"
                        "paginaFinal" => "173"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11322920"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            14 => array:3 [
              "identificador" => "bib0220"
              "etiqueta" => "15"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Percutaneous occlusion of patent ductus arteriosus with controlled-release coil"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "A&#46;S&#46; Kumar"
                            1 => "A&#46; Kapor"
                            2 => "N&#46; Sinha"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Asian Cardiovasc Thorac Ann"
                        "fecha" => "1999"
                        "volumen" => "7"
                        "paginaInicial" => "204"
                        "paginaFinal" => "208"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            15 => array:3 [
              "identificador" => "bib0225"
              "etiqueta" => "16"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "The PDA coil registry&#58; report of the first 535 procedures"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "T&#46;R&#46; Lloyd"
                            1 => "R&#46;H&#46; Beekman"
                            2 => "I&#46;I&#46; J&#46;W&#46; Moore"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:4 [
                        "tituloSerie" => "Circulation"
                        "fecha" => "1995"
                        "volumen" => "92"
                        "paginaInicial" => "I380"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            16 => array:3 [
              "identificador" => "bib0230"
              "etiqueta" => "17"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Coil occlusion of patent ductus arteriosus"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "H&#46; Tomita"
                            1 => "M&#46; Takamuro"
                            2 => "S&#46; Fuse"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1253/circj.70.28"
                      "Revista" => array:6 [
                        "tituloSerie" => "Circ J"
                        "fecha" => "2006"
                        "volumen" => "70"
                        "paginaInicial" => "28"
                        "paginaFinal" => "30"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/16377920"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            17 => array:3 [
              "identificador" => "bib0235"
              "etiqueta" => "18"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Multicenter USA Amplatzer patent ductus arteriosus occlusion device trial&#58; initial and one-year results"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "R&#46;H&#46; Pass"
                            1 => "Z&#46; Hijazi"
                            2 => "D&#46;T&#46; Hsu"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.jacc.2004.03.074"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Am Coll Cardiol"
                        "fecha" => "2004"
                        "volumen" => "44"
                        "paginaInicial" => "513"
                        "paginaFinal" => "519"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/15358013"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            18 => array:3 [
              "identificador" => "bib0240"
              "etiqueta" => "19"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Report of the European Registry Transcatheter occlusion of persistent arterial duct"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:1 [
                            0 => "M&#46; Tynan"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Lancet"
                        "fecha" => "1992"
                        "volumen" => "340"
                        "paginaInicial" => "1062"
                        "paginaFinal" => "1066"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/1357454"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            19 => array:3 [
              "identificador" => "bib0245"
              "etiqueta" => "20"
              "referencia" => array:1 [
                0 => array:1 [
                  "referenciaCompleta" => "Antunes Sarmento J&#44; Correia-Costa A&#44; Gon&#231;alves E&#44; et al&#46;&#44; Percutaneous patent ductus arteriosus closure&#58; Twelve years of experience&#46; Rev Port Cardiol&#46; https&#58;&#47;&#47;doi&#46;org&#47;10&#46;1016&#47;j&#46;repc&#46;2020&#46;09&#46;008"
                ]
              ]
            ]
            20 => array:3 [
              "identificador" => "bib0250"
              "etiqueta" => "21"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Safety and efficacy of transcatheter closure of large patent ductus arteriosus in adults with a self-expandable occluder"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "M&#46;L&#46; Yu"
                            1 => "X&#46;M&#46; Huang"
                            2 => "J&#46;F&#46; Wang"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1007/s00380-009-1150-5"
                      "Revista" => array:6 [
                        "tituloSerie" => "Heart Vessels"
                        "fecha" => "2009"
                        "volumen" => "24"
                        "paginaInicial" => "440"
                        "paginaFinal" => "445"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20108077"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            21 => array:3 [
              "identificador" => "bib0255"
              "etiqueta" => "22"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "To close or not to close&#58; the very small patent ductus arteriosus"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "E&#46;B&#46; Fortescue"
                            1 => "J&#46;E&#46; Lock"
                            2 => "T&#46; Galvin"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1111/j.1747-0803.2010.00435.x"
                      "Revista" => array:7 [
                        "tituloSerie" => "Congenit Heart Dis"
                        "fecha" => "2010"
                        "volumen" => "5"
                        "paginaInicial" => "354"
                        "paginaFinal" => "365"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20653702"
                            "web" => "Medline"
                          ]
                        ]
                        "itemHostRev" => array:3 [
                          "pii" => "S0022347612004301"
                          "estado" => "S300"
                          "issn" => "00223476"
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            22 => array:3 [
              "identificador" => "bib0260"
              "etiqueta" => "23"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Significant persistent ductus arteriosus in infants less or equal to 6 kg&#58; percutaneous closure or surgery&#63;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "S&#46; Abadir"
                            1 => "Y&#46; Boudjemline"
                            2 => "C&#46; Rey"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Arch Cardiovasc Dis"
                        "fecha" => "2009"
                        "volumen" => "102"
                        "paginaInicial" => "533"
                        "paginaFinal" => "540"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            23 => array:3 [
              "identificador" => "bib0265"
              "etiqueta" => "24"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Outcomes of transcatheter occlusion of patent ductus arteriosus in infants weighing &#8804;6 kg"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "V&#46;V&#46; Dimas"
                            1 => "C&#46; Takao"
                            2 => "F&#46;F&#46; Ing"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "J Am Coll Cardiol Intv"
                        "fecha" => "2010"
                        "volumen" => "3"
                        "paginaInicial" => "1295"
                        "paginaFinal" => "1299"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            24 => array:3 [
              "identificador" => "bib0270"
              "etiqueta" => "25"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Transcatheter closure of patent ductus arteriosus in under 6 kg and premature infants"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "O&#46; Baspinar"
                            1 => "D&#46;A&#46; Sahin"
                            2 => "A&#46; Sulu"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1111/joic.12196"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Interv Cardiol"
                        "fecha" => "2015"
                        "volumen" => "28"
                        "paginaInicial" => "180"
                        "paginaFinal" => "189"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25832591"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            25 => array:3 [
              "identificador" => "bib0275"
              "etiqueta" => "26"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Improved ventilation in premature babies after transcatheter versus surgical closure of patente ductus arteriosus"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "W&#46; Regan"
                            1 => "N&#46; Benbrik"
                            2 => "S&#46;R&#46; Sharma"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Int J Cardiol"
                        "fecha" => "2020"
                        "volumen" => "311"
                        "paginaInicial" => "22"
                        "paginaFinal" => "27"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            26 => array:3 [
              "identificador" => "bib0280"
              "etiqueta" => "27"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Operation for adult patent ductus arteriosus using cardiopulmonary bypass"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "R&#46; Toda"
                            1 => "Y&#46; Moriyama"
                            2 => "M&#46; Ymashita"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Ann Thorac Surg"
                        "fecha" => "2000"
                        "volumen" => "70"
                        "paginaInicial" => "1935"
                        "paginaFinal" => "1937"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            27 => array:3 [
              "identificador" => "bib0285"
              "etiqueta" => "28"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Trnasfemoral closure of patent ductus arteriosus in adult patients"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "P&#46; Bonhoeffer"
                            1 => "A&#46; Borghi"
                            2 => "E&#46; Onorato"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/0167-5273(93)90036-g"
                      "Revista" => array:6 [
                        "tituloSerie" => "Int J Cardiol"
                        "fecha" => "1993"
                        "volumen" => "39"
                        "paginaInicial" => "181"
                        "paginaFinal" => "186"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/8335409"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            28 => array:3 [
              "identificador" => "bib0290"
              "etiqueta" => "29"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Trnascatheter closure of patent ductus arteriosus in adults using the Amplatzer duct occluder&#58; initial resuls and follow-up"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "T&#46;E&#46; Hong"
                            1 => "W&#46;E&#46; Hellenbrand"
                            2 => "M&#46; Hijazi"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Indian Heart J"
                        "fecha" => "2002"
                        "volumen" => "54"
                        "paginaInicial" => "384"
                        "paginaFinal" => "389"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/12462665"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
          ]
        ]
      ]
    ]
  ]
  "idiomaDefecto" => "en"
  "url" => "/08702551/0000004000000008/v1_202108010531/S0870255121002511/v1_202108010531/en/main.assets"
  "Apartado" => array:4 [
    "identificador" => "29261"
    "tipo" => "SECCION"
    "en" => array:2 [
      "titulo" => "Artigos Originais"
      "idiomaDefecto" => true
    ]
    "idiomaDefecto" => "en"
  ]
  "PDF" => "https://static.elsevier.es/multimedia/08702551/0000004000000008/v1_202108010531/S0870255121002511/v1_202108010531/en/main.pdf?idApp=UINPBA00004E&text.app=https://revportcardiol.org/"
  "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0870255121002511?idApp=UINPBA00004E"
]
Partilhar
Informação da revista
Vol. 40. Núm. 8.
Páginas 569-571 (agosto 2021)
Partilhar
Partilhar
Baixar PDF
Mais opções do artigo
Vol. 40. Núm. 8.
Páginas 569-571 (agosto 2021)
Editorial comment
Open Access
Percutaneous closure of patent ductus arteriosus: A standard procedure with new perspectives
Encerramento percutâneo de canal arterial persistente: um procedimento padrão com novas perspetivas
Visitas
3264
Fátima F. Pinto
Universidade NOVA de Lisboa, Serviço de Cardiologia Pediátrica, Centro de Referência de Cardiopatias Congénitas, CHULC, EPE – Hospital de Santa Marta, Portugal
Este item recebeu

Under a Creative Commons license
Informação do artigo
Texto Completo
Bibliografia
Baixar PDF
Estatísticas
Texto Completo

Patent ductus arteriosus (PDA) is one of the most frequent congenital heart defects and may occur as an isolated lesion or in association with others. Its incidence varies from 5% to 10% of all congenital heart disease in term infants,1 increasing to 20% to 60% in preterm neonates. This is attributable to the lack of normal closure mechanisms due to immaturity in the premature neonate.2 Most patients have a small to moderate PDA causing restrictive flow with small left-to-right shunt, presenting as symptom-free or with few symptoms. The natural history of these lesions would probably be uneventful, except for the risk of infective endocarditis. Moderate to large PDA will cause an unrestrictive flow, with potential for congestive heart failure (HF) and pulmonary vascular disease. The rational for PDA closure is to prevent late complications such as canaliculitis, HF or Eisenmenger syndrome in late age. Exceptions are neonate or preterm infants with large PDA and the presence of severe pulmonary hypertension.

Since the first successful reports of surgical treatment of a PDA, by Gross and Hubbard in 1939,3 surgical technique—either ligation of division—has been widely used for large and symptomatic PDA. Although it has been shown that surgery is safe and effective with only occasional complications and some cases of recanalization, pediatric cardiologists have always tried to develop a transcatheter method to close PDA and other anomalies.

The first report on non-surgical closure was by Portsmann et al. in 1967.4 This investigator along with Rashkind et al.5 pioneered the development of several PDA closure devices. Due to their efforts, PDA percutaneous occlusion became an effective and safe procedure, and is nowadays the standard method for PDA closure.

After these initial devices, various types of occlusion systems have been developed. Gianturco, Jackson coils (both free and detachable) and similar devices have become an established method for PDA transcatheter closure.6–9 Since 1992, coils have evolved into the most commonly used devices for small-sized PDA occlusion. The introduction of the Amplatzer® duct occluder family (ADO, Abbott, USA) in 2001, changed the perspective on this procedure, because of increased safety characteristics, like retrievability, repositioning and also the possibility to close defects up to 16 mm in diameter. They are among the most frequently used occluders for large and moderate PDA occlusion.10–12 Another recent device is the Nit-Occlud® (NOc, pfm, Germany) coil, which was designed specifically for PDA closure. This coil has undergone several modifications since it was first developed, with the latest version in use since 2001.13,14 Procedures using these techniques were reported to be safe and effective, and although complications occur, critical complications are rare.6–14 Device embolization, the most feared complication, was relatively common in early experience with coils but became rare with the new generation of devices. Reported occlusion rates vary according to operator experience, and post procedure period, from 41% immediately after the procedure to 95 to 100% at three months of follow up.15–18 Nevertheless, several studies have demonstrated that intermediate and long-term outcomes of percutaneous PDA occlusion with current devices are excellent.17–19

In the present study, Sarmento et al.20 present the results with percutaneous PDA occlusion from a single center for twelve years using at least three different devices. The authors claim to report one of the largest series using the PDA NOc devices, which adds value to the study. In their series, the immediate procedural occlusion rate, assessed by angiography, was high (98.6%), with a low complication rate (1.8%), and a single case of embolization, in line with other reported data.10,21 The success rate was associated with vascular accessibility, morphology of the ductus, imaging modality, and adequate selection of the device. The study adds no novelty to the technique, but reports on an important case experience at national level. However, the authors fail to explain the set for “adequate selection of device” and the criteria for performing coil/device closure. Also, regarding the results, the reported occlusion rate refers to the immediate result, assessed by aortography. The study would be more robust if the authors had described the immediate or 24-hour occlusion rate assessed by echocardiography, which would enable a more accurate assessment and long-term outcomes, as we would expect from a twelve-year retrospective study. Despite these limitations, the study is of value and it gives us the opportunity to discuss issues germane to transcatheter PDA closure, such as indications, selection of devices, expected results and future perspectives.

Percutaneous PDA occlusion is indicated for lesions presenting with suggestive continuous murmur, confirmed by echocardiography. Ductus with absence of these typical findings, so-called ‘silent ductus’, should not be occluded, although controversy exists with some authors recommending occlusion.22 Small size PDA without significant left ventricle overflow should be treated to prevent infective endocarditis. Medium and large size defects, which present significant left-to-right shunt, are treated to prevent HF and pulmonary vascular occlusive disease.

Adequate patient age and size have been an issue, and indications have evolved over time and with new and innovative PDA occluding devices. Until recently, transcatheter PDA closure was considered the procedure of choice for infants ≥6 kg and adults. Although an exact lower weight limit has not been set for a safe occlusion, only a few studies have reported results in neonates and infants below this weight threshold.23–25 Recently, these limits have been exceeded with the release of the new miniaturized devices adequate for premature infants under 1.5 kg. There is an ongoing prospective trial to compare the classic surgical approach to percutaneous PDA occlusion in preterm infants over 700 g and three days old, using the Amplatzer® Piccolo Occluder, an evolution of the Amplatzer® additional sizes (ADO AS) family devices.26 These advances, although with promising early and mid-term results, need to be confirmed in randomized controlled trials before they can become a standard of care.

Patent ductus arteriosus is an uncommon anomaly in adults, but in this age group they present several pathological changes, such as tortuosity, calcification, friability, aneurysm formation and ductal shortening.27 A calcified duct is more fragile and difficult to cross and the treatment option was surgery with cardiopulmonary bypass, to overcome complexity and complications. However, the development of new occlusion devices that can be deployed on the arterial side have enabled percutaneous occlusion in adult patients.28,29 Treatment selection must, however, be made on an individual bases, especially in heavily calcified and fragile ducts. Although there are no specific guidelines for device selection, it seems logical that a less rigid device such as ADO II, ADO II AS, vascular plugs and PDA NOc would cause less shear stress on these fragile walls.

Based on personal experience,9,12 most PDA can be occluded using a percutaneous approach, keeping in mind that the selection of patients and devices remains the major factor for success and effectiveness, so it is important to take into account patient characteristics, PDA shape, size and minimal diameter. Small to very-small PDA (<2.5 and 1.5 mm in diameter respectively, with continuous murmur) can easily be occluded, regardless of their shape, using detachable coils, which are a cheap and effective choice. Device selection for conical PDA is broader, as either coils or ADO devices and similar can be used depending on the size and minimum diameter of the PDA. Although there is no exact threshold, the latter are usually used to occlude PDA over 2.5 mm in diameter. The PDA NOc devices are recommended, in most studies, to occlude small to moderate PDA, as shown by the authors of this study report. ADO devices are used with greater efficiency in ductus of a larger diameter or morphology that is unfavorable to occlusion with coils.

Complete PDA occlusion and absence of complications are the expected results of percutaneous PDA occlusion. Residual shunting is more common with coils and when it occurs, it has to be treated with repeated procedures, as it may lead to endocarditis or to hemolysis. Device embolization is rare and also more frequent with coils, with an occurrence rate <1%. Device-induced pulmonary branch stenosis or aortic coarctation is rarely seen, although Döppler flow acceleration without invasive gradient may occur, it might resolve spontaneously with growth. Aortography, before and after releasing the implanted device, is the method selected to evaluate immediate result, but echocardiography is more adequate for post-procedural assessment and quantification of incomplete occlusion and late complications. We should however point out, that when using coils, we would recommend continuing catheterization until complete ductal closure is documented by angiography, because of increased risk of embolization and hemolysis. Vascular injury from the delivery system is another feared complication, especially in small infants. Nevertheless, this is rarely seen with experienced operators, also taking into account the evolution in downsizing delivery sheaths over the last five decades.

Finally, transcatheter PDA closure stands as the standard treatment in most cases. Coils and ADO devices or similar are the most frequently used closure devices worldwide. This approach is feasible, effective and safe with current devices and techniques leading to excellent outcomes. Future perspectives foresee the evolution of techniques to address more challenging cases, such as preterm and low birth weight infants and complex cases in adults, with high occlusion rate and few complications. During the past 50 years, we have witnessed a remarkable evolution in techniques, devices and delivery systems, so we can only anticipate further improvements in transcatheter PDA closure.

Conflicts of interest

The author has no conflicts of interest to declare.

References
[1]
D.J. Schneider, J.W. Moore.
Patent ductus arteriosus.
Circulation, 114 (2006), pp. 1873-1882
[2]
M.E. Hajjar, G. Vaksmann, T. Rakza, et al.
Severity of the ductal shunt: a comparison of different markers.
Arch Dis Child Fetal Neonatal Ed, 90 (2005), pp. F419-F422
[3]
R.E. Gross, J.P. Hubbard.
Surgical ligation of patent ductus arteriosus: a report of first successful case.
J Am Med Assoc, 112 (1939), pp. 729-731
[4]
W. Porstmann, L. Wierny, H. Warnke.
Closure of persistent ductus arteriosus without thoracotomy.
Ger Med Mon, 12 (1967), pp. 259-261
[5]
W.J. Rashkind, C.E. Mullins, W.E. Hellenbrand, et al.
Nonsurgical closure of patent ductus arteriosus: clinical application of the Rashkind PDA Occluder System.
Circulation, 75 (1987), pp. 583-592
[6]
C. Gianturco, J.H. Anderson, S. Wallace.
Mechanical device for arterial occlusion.
Am J Roentgen, 124 (1975), pp. 428-435
[7]
P.A. Cambier, W.C. Kirby, D.C. Wortham, et al.
Percutaneous closure of small (<2.5 mm) patent ductus arteriosus using coil embolization.
Am J Cardiol, 69 (1992), pp. 815-816
[8]
A.J. Tometzki, R. Arnold, I. Peart, et al.
Transcatheter occlusion of patent ductus arteriosus with Cook detachable coils.
Heart, 76 (1996), pp. 531-535
[9]
S. Kaku, F.F. Pinto, R. Ferreira, et al.
Oclusão do canal arterial por via percutânea com filamentos helicoidais de separação controlável.
Rev Port Cardiol, 15 (1996), pp. 913-916
[10]
J. Masura, K.P. Walsh, B. Thanopoulous, et al.
Catheter closure of moderate- to large-sized patent ductus arteriosus using the new Amplatzer duct occluder: immediate and short-term results.
J Am Coll Cardiol, 31 (1998), pp. 878-882
[11]
J.K. Wang, M.H. Wu, M.T. Lin, et al.
Transcatheter closure of moderate-to-large patent ductus arteriosus in infants using Amplatzer duct occluder.
Circ J, 74 (2010), pp. 361-364
[12]
F.F. Pinto, trigo c, G. Nogueira, et al.
Oclusão percutânea de canal arterial persistente com o novo dispositivo de Amplatzer: resultados imediatos e a médio-prazo.
Rev Port Cardiol, 20 (2001), pp. 81
[13]
A. Tometzki, K. Chan, J. De Giovanni, et al.
Total UK multi-centre experience with a novel arterial occlusion device (Duct-Occlud pfm).
Heart, 76 (1996), pp. 520-524
[14]
T.P. Le, J.W. Moore, M.B. Neuss, et al.
Duct-occlud for occlusion of patent ductus arteriosus.
Curr Interv Cardiol Rep, 3 (2001), pp. 165-173
[15]
A.S. Kumar, A. Kapor, N. Sinha, et al.
Percutaneous occlusion of patent ductus arteriosus with controlled-release coil.
Asian Cardiovasc Thorac Ann, 7 (1999), pp. 204-208
[16]
T.R. Lloyd, R.H. Beekman, I.I. J.W. Moore, et al.
The PDA coil registry: report of the first 535 procedures.
Circulation, 92 (1995), pp. I380
[17]
H. Tomita, M. Takamuro, S. Fuse, et al.
Coil occlusion of patent ductus arteriosus.
Circ J, 70 (2006), pp. 28-30
[18]
R.H. Pass, Z. Hijazi, D.T. Hsu, et al.
Multicenter USA Amplatzer patent ductus arteriosus occlusion device trial: initial and one-year results.
J Am Coll Cardiol, 44 (2004), pp. 513-519
[19]
M. Tynan.
Report of the European Registry Transcatheter occlusion of persistent arterial duct.
Lancet, 340 (1992), pp. 1062-1066
[20]
Antunes Sarmento J, Correia-Costa A, Gonçalves E, et al., Percutaneous patent ductus arteriosus closure: Twelve years of experience. Rev Port Cardiol. https://doi.org/10.1016/j.repc.2020.09.008
[21]
M.L. Yu, X.M. Huang, J.F. Wang, et al.
Safety and efficacy of transcatheter closure of large patent ductus arteriosus in adults with a self-expandable occluder.
Heart Vessels, 24 (2009), pp. 440-445
[22]
E.B. Fortescue, J.E. Lock, T. Galvin, et al.
To close or not to close: the very small patent ductus arteriosus.
Congenit Heart Dis, 5 (2010), pp. 354-365
[23]
S. Abadir, Y. Boudjemline, C. Rey, et al.
Significant persistent ductus arteriosus in infants less or equal to 6 kg: percutaneous closure or surgery?.
Arch Cardiovasc Dis, 102 (2009), pp. 533-540
[24]
V.V. Dimas, C. Takao, F.F. Ing, et al.
Outcomes of transcatheter occlusion of patent ductus arteriosus in infants weighing ≤6 kg.
J Am Coll Cardiol Intv, 3 (2010), pp. 1295-1299
[25]
O. Baspinar, D.A. Sahin, A. Sulu, et al.
Transcatheter closure of patent ductus arteriosus in under 6 kg and premature infants.
J Interv Cardiol, 28 (2015), pp. 180-189
[26]
W. Regan, N. Benbrik, S.R. Sharma, et al.
Improved ventilation in premature babies after transcatheter versus surgical closure of patente ductus arteriosus.
Int J Cardiol, 311 (2020), pp. 22-27
[27]
R. Toda, Y. Moriyama, M. Ymashita, et al.
Operation for adult patent ductus arteriosus using cardiopulmonary bypass.
Ann Thorac Surg, 70 (2000), pp. 1935-1937
[28]
P. Bonhoeffer, A. Borghi, E. Onorato, et al.
Trnasfemoral closure of patent ductus arteriosus in adult patients.
Int J Cardiol, 39 (1993), pp. 181-186
[29]
T.E. Hong, W.E. Hellenbrand, M. Hijazi.
Trnascatheter closure of patent ductus arteriosus in adults using the Amplatzer duct occluder: initial resuls and follow-up.
Indian Heart J, 54 (2002), pp. 384-389
Copyright © 2021. Sociedade Portuguesa de Cardiologia
Baixar PDF
Idiomas
Revista Portuguesa de Cardiologia
Opções de artigo
Ferramentas
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Ao assinalar que é «Profissional de Saúde», declara conhecer e aceitar que a responsável pelo tratamento dos dados pessoais dos utilizadores da página de internet da Revista Portuguesa de Cardiologia (RPC), é esta entidade, com sede no Campo Grande, n.º 28, 13.º, 1700-093 Lisboa, com os telefones 217 970 685 e 217 817 630, fax 217 931 095 e com o endereço de correio eletrónico revista@spc.pt. Declaro para todos os fins, que assumo inteira responsabilidade pela veracidade e exatidão da afirmação aqui fornecida.