Informação da revista
Vol. 31. Núm. 3.
Páginas 247-250 (março 2012)
Partilhar
Partilhar
Baixar PDF
Mais opções do artigo
Vol. 31. Núm. 3.
Páginas 247-250 (março 2012)
Case report
Open Access
Cardiac 123I-MIBG scintigraphy and arrhythmic risk in left ventricular noncompaction
Visitas
5095
Sílvia Marta Oliveiraa,b,
Autor para correspondência
silviamartaoliveira@hotmail.com

Corresponding author.
, Elisabete Martinsa,b, Ana Oliveirac, Teresa Pinhoa,b, Cristina Gavinaa,b, Teresa Fariac, José Carlos Silva-Cardosoa,b, Jorge Pereirac, Maria Júlia Maciela,b
a Cardiology Department, Hospital de São João, Porto, Portugal
b Faculty of Medicine, Porto University, Porto, Portugal
c Nuclear Medicine Department, Hospital de São João, Porto, Portugal
Este item recebeu

Under a Creative Commons license
Informação do artigo
Abstract

Left ventricular noncompaction is an unusual but increasingly recognized cardiomy-opathy, the etiology of which is still not definitely established. Clinical presentation includes a wide spectrum of scenarios, including heart failure, thromboembolism and malignant arrhyth-mias, with half of deaths occurring suddenly. Early detection of LVNC is therefore essential to prevent sudden cardiac death. To our knowledge, this is the first report of the presence of cardiac sympathetic nervous dysfunction, assessed by 123iodine-metaiodobenzylguanidine myocardial scintigraphy, in a patient with LVNC, preserved left ventricular systolic function and exercise-induced nonsustained ventricular tachycardia. This finding may be related to the increased arrhythmic risk observed in this cardiomyopathy, giving a new insight into the pathophysiology of LVNC.

Keywords:
Cardiac 123I-MIBG scintigraphy
Left ventricular noncompaction
Arrhythmias
Palavras chave:
Cintigrafia cardíaca com 123I-MIBG
Miocárdio não-compactado
Arritmias
Resumo

O miocárdio não-compactado (MNC) é uma miocardiopatia que, embora rara, tem sido gradualmente mais descrita. O espectro de apresentac, ão clínica é variável, incluindo insufi-ciência cardíaca, fenómenos tromboembólicos e arritmias, sendo que metade das mortes ocorre subitamente (MSC). Por conseguinte, o diagnóstico precoce e correto do MNC é fundamental para a prevenc¸ão da MSC. O presente artigo ilustra pela primeira vez a presenc¸a de disfunc¸ão neuronal simpática, avaliada por cintigrafia cardíaca com 123I-metaiodobenzilguinadina, num doente com MNC, func¸ão sistólica ventricular esquerda preservada e taquicardia não susten-tada induzida pelo esforc¸o. A presenc¸a de alterac¸ões na actividade adrenérgica cardíaca pode estar relacionada com o maior risco arrítmico característico desta miocardiopatia, podendo contribuir para o melhor esclarecimento da sua patofisiologia.

O texto completo está disponível em PDF
References
[1]
R.M. Freedom, S.J. Yoo, D. Perrin, et al.
The morphologi-cal spectrum of ventricular noncompaction.
Cardiol Young., 15 (2005), pp. 345-364
[2]
U. Bartram, J. Bauer, D. Schranz.
Primary noncompaction of the ventricular myocardium from the morphogenetic standpoint.
Pediatr Cardiol., 28 (2007), pp. 325-332
[3]
E.N. Oechslin, C.H. Attenhofer Jost, J.R. Rojas, et al.
Long-term follow-up of 34 adults with isolated left ventricular noncom-paction: a distinct cardiomyopathy with poor prognosis.
J Am Coll Cardiol., 36 (2000), pp. 493-500
[4]
R. Jenni, E. Oechslin, J. Schneider, et al.
Echocardiographic and pathoanatomical characteristics of isolated left ventricu-lar non-compaction: a step towards classification as a distinct cardiomyopathy.
Heart., 86 (2001), pp. 666-671
[5]
C. Stollberger, J. Finsterer, G. Blazek.
Left ventricular hyper-trabeculation/noncompaction and association with additional cardiac abnormalities and neuromuscular disorders.
Am J Car-diol., 90 (2002), pp. 899-902
[6]
S.E. Petersen, J.B. Selvanayagam, F. Wiesmann, et al.
Left ven-tricular non-compaction: insights from cardiovascular magnetic resonance imaging.
J Am Coll Cardiol., 46 (2005), pp. 101-105
[7]
K. Caliskan, T. Szili-Torok, D.A. Theuns, et al.
Indications and outcome of implantable cardioverter-defibrillators for primary and secondary prophylaxis in patients with noncompaction car-diomyopathy.
J Cardiovasc Electrophysiol., 22 (2011), pp. 898-904
[8]
D. Agostini, H.J. Verberne, W. Burchert, et al.
I-123-mIBG myocar-dial imaging for assessment of risk for a major cardiac event in heart failure patients: insights from a retrospective European multicenter study.
Eur J Nucl Med Mol Imaging., 35 (2008), pp. 535-546
[9]
H.J. Verberne, L.M. Brewster, G.A. Somsen, et al.
Prognostic value of myocardial 123I-metaiodobenzylguanidine (MIBG) parameters in patients with heart failure: a systematic review.
Eur Heart J, 29 (2008), pp. 1147-1159
[10]
S. Tamaki, T. Yamada, Y. Okuyama, et al.
Cardiac iodine- 123 metaiodobenzylguanidine imaging predicts sudden cardiac death independently of left ventricular ejection fraction in patients with chronic heart failure and left ventricular systolic dysfunction: results from a comparative study with signal-averaged electrocardiogram, heart rate variability, and QT dispersion.
J Am Coll Cardiol., 53 (2009), pp. 426-435
[11]
S. Katoh, T. Shishido, D. Kutsuzawa, et al.
Iodine-123- metaiodobenzylguanidine imaging can predict future cardiac events in heart failure patients with preserved ejection frac-tion.
Ann Nucl Med., 24 (2010), pp. 679-686
[12]
T. Kaneda, M. Shimizu, H. Ino, et al.
Images in cardiovascular medicine. Adult patient with isolated noncompaction of ven-tricular myocardium.
Circulation, 112 (2005), pp. e96-e97
Copyright © 2011. Sociedade Portuguesa de Cardiologia
Baixar PDF
Idiomas
Revista Portuguesa de Cardiologia
Opções de artigo
Ferramentas
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Ao assinalar que é «Profissional de Saúde», declara conhecer e aceitar que a responsável pelo tratamento dos dados pessoais dos utilizadores da página de internet da Revista Portuguesa de Cardiologia (RPC), é esta entidade, com sede no Campo Grande, n.º 28, 13.º, 1700-093 Lisboa, com os telefones 217 970 685 e 217 817 630, fax 217 931 095 e com o endereço de correio eletrónico revista@spc.pt. Declaro para todos os fins, que assumo inteira responsabilidade pela veracidade e exatidão da afirmação aqui fornecida.