Image in Cardiology
Open Access
Utility of catheter extension devices in coronary artery anomalies
Utilidade dos extensores do cateter em anomalias coronárias
Visits
3309
Eva Rumiz
Corresponding author
evarumiz@hotmail.com

Corresponding author.
, Ernesto Valero, Juan Vicente Vilar, Pablo Almela, Javier Haba
Cardiology Department, Hospital Quirónsalud Valencia, Valencia, Spain
This item has received

Under a Creative Commons license
Article information
Full Text
Download PDF
Statistics
Figures (1)
Full Text

We report the case of a 72-year-old woman with a history of hypertension and dyslipidemia, who came to the outpatient clinic complaining of chest pain. Exercise stress test was positive. Coronary angiography (Figure 1A) by radial approach showed a right coronary artery (RCA) with an anomalous origin at the left sinus of Valsalva, next to the origin of the left main coronary artery, with severe stenosis in the middle segment (arrow). Due to its anomalous origin, selective catheterization of the RCA could not be achieved with any type of guide catheter; the Amplatz-Left-1 allowed the best approach. The use of a catheter extension device (Figure 1B, arrow) enabled selective intubation of the anomalous ostium, advancing the angioplasty balloon and pre-dilation of the stenosis. Subsequently, with the help of the catheter extension device, we implanted a drug-eluting stent in the RCA (Figure 1C) with an excellent final angiographic result (Figure 1D).

Figure 1.

(A) Right coronary angiography showing an anomalous origin and severe stenosis in the middle segment (arrow). (B) Right coronary catheterization using the catheter extension device. (C) Stent delivery. (D) Final angiographic result.

(0.21MB).

Interventional cardiologists face a number of technical challenges when attempting to treat anomalous coronary arteries. The very low incidence of anomalies and the unique characteristics of each one make it essential to individualize the approach in each patient, with the correct selection of the guiding catheter and the use of alternative techniques and devices being particularly important. In our case, the use of the catheter extension device permitted selective catheterization of the anomalous coronary artery and provided us with sufficient support to successfully perform the angioplasty.

Conflicts of interest

The authors have no conflicts of interest to declare.

Copyright © 2018. Sociedade Portuguesa de Cardiologia
Download PDF
Idiomas
Revista Portuguesa de Cardiologia (English edition)
Article options
Tools
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

By checking that you are a health professional, you are stating that you are aware and accept that the Portuguese Journal of Cardiology (RPC) is the Data Controller that processes the personal information of users of its website, with its registered office at Campo Grande, n.º 28, 13.º, 1700-093 Lisbon, telephone 217 970 685 and 217 817 630, fax 217 931 095, and email revista@spc.pt. I declare for all purposes that the information provided herein is accurate and correct.