Journal Information
Vol. 37. Issue 1.
Pages 91-92 (January 2018)
Share
Share
Download PDF
More article options
Vol. 37. Issue 1.
Pages 91-92 (January 2018)
Image in Cardiology
Open Access
Iatrogenic aortic dissection – Follow the image!
Dissecção da aorta iatrogénica – segue a imagem!
Visits
4309
Catarina Vieiraa,
Corresponding author
cfvieira1982@hotmail.com

Corresponding author.
, Nuno Bettencourtb, Nuno Ferreirab, Mónica Carvalhob, Vasco Gamab
a Cardiology Department, Hospital de Braga, Braga, Portugal
b Cardiology Department, Centro Hospitalar de Vila Nova de Gaia/Espinho, Vila Nova de Gaia, Espinho, Portugal
This item has received

Under a Creative Commons license
Article information
Full Text
Download PDF
Statistics
Figures (2)
Full Text

A 74-year-old woman with hypertension and dyslipidemia was referred to the cardiology outpatient clinic with dyspnea on moderate exertion. Physical examination was unremarkable. ECG had left ventricular hypertrophy voltage criteria. Transthoracic echocardiogram showed mild dilation of the left chambers and hypokinesia of inferior, posterior and lateral walls with mild depression of left ventricular systolic function. Because of the findings in the echocardiogram she was referred for invasive coronary angiography (CA) without an ischemia test.

Left CA showed no coronary disease. After the first contrast injection in the right coronary artery (RCA)—which also excluded disease—a radiopaque area was seen in the aortic wall, suggesting catheter-induced (iatrogenic) ascending aortic dissection (IAD) (Figure 1, Panel A, arrow). A few minutes later, occlusion of RCA occurred as a result of dissection progression (Figure 1, Panel B, arrow). CT angiography (CTA) performed immediately in the hemodynamics laboratory (same room, moving gantry) confirmed IAD dissection and acute occlusion of the RCA (Figure 2A, B and C, arrows). Angioplasty of RCA was tried without success because it was not possible to catheterize the true lumen. Bedside echocardiogram showed mild depression of global systolic function of the left ventricle with akinesia of the inferior wall and hypokinesia of the free wall of the right ventricle. As percutaneous intervention was not possible, the patient was referred for coronary artery bypass grafting, but this was refused because of the “location” of the infarction, the relative hemodynamic stability of the patient and the lack of signs of dissection progression. A conservative approach was therefore adopted. The patient developed an inferior myocardial infarction but had a good clinical and hemodynamic recovery. Peak troponin I was 11 ng/mL. One week later, repeat CTA revealed IAD regression (Figure 2G and H, arrows) and spontaneous RCA reperfusion (Figure 2I, arrow).

Figure 1.

Coronary angiogram showing radiopaque area in the ascending aortic wall (Panel A) and acute occlusion of RCA (Panel B).

(0.29MB).
Figure 2.

Thin (3 mm) maximal intensity projection reconstructions in coronal (first row) and transverse planes (second and third rows) of the multidetector chest CT scan performed on the first day (Panels A, B, C), on the second day (panels D, E, F) and one week later (Panels G, H, I), showing how the ascending aortic dissection and RCA occlusion and reperfusion evolved.

(0.6MB).
Conflicts of interest

The authors have no conflicts of interest to declare.

Copyright © 2017. Sociedade Portuguesa de Cardiologia
Download PDF
Idiomas
Revista Portuguesa de Cardiologia (English edition)
Article options
Tools
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

By checking that you are a health professional, you are stating that you are aware and accept that the Portuguese Journal of Cardiology (RPC) is the Data Controller that processes the personal information of users of its website, with its registered office at Campo Grande, n.º 28, 13.º, 1700-093 Lisbon, telephone 217 970 685 and 217 817 630, fax 217 931 095, and email revista@spc.pt. I declare for all purposes that the information provided herein is accurate and correct.