Journal Information
Vol. 34. Issue 11.
Pages 701-702 (November 2015)
Vol. 34. Issue 11.
Pages 701-702 (November 2015)
Image in Cardiology
Open Access
Giant right coronary aneurysm untreatable by percutaneous intervention
Aneurisma gigante e intratável percutaneamente da coronária direita
Visits
5116
Bruno Marmelo
Corresponding author
brunomarmelo@gmail.com

Corresponding author.
, Anne Delgado, Davide Moreira, João Pipa, Pedro Ferreira, Oliveira Santos
Serviço de Cardiologia, Centro Hospitalar Tondela-Viseu, Viseu, Portugal
This item has received

Under a Creative Commons license
Article information
Full Text
Download PDF
Statistics
Figures (4)
Show moreShow less
Full Text

A 62-year-old man went to the emergency room of the nearest hospital to his holiday location due to general malaise and jaw pain of four hours duration and was diagnosed with inferior myocardial infarction (MI). He had suffered an MI four years previously in France, when stents had been implanted in the right coronary and circumflex arteries. Since the center had no facilities for percutaneous coronary intervention (PCI), fibrinolysis was performed within 30 min and he was then transferred to a PCI-capable center. Coronary angiography revealed a giant aneurysm of the mid segment of the right coronary artery involving the proximal portion of the stent, with a recanalized thrombus (Figure 1). PCI to exclude the aneurysm was attempted but it proved impossible to cross the stent with the guide wires employed. The proximal portion of the stent appeared to be occluded, with flow through the side mesh. A further attempt at PCI was made a few days later, which revealed an organized thrombus (Figure 2). The side mesh of the stent was crossed but the balloon could not be advanced (Figure 3). Figure 4 shows the final result.

Figure 1.

Giant aneurysm in the mid segment of the right coronary artery, involving the proximal portion of the stent, with a luminal thrombus.

(0.07MB).
Figure 2.

Visualization of an organized thrombus and flow through the stent mesh one week after the acute event.

(0.08MB).
Figure 3.

The guide wire crossed the side mesh of the stent, but the balloon could not be advanced.

(0.07MB).
Figure 4.

Final result.

(0.07MB).

This case highlights the value of prompt fibrinolysis, which proved to be the ideal treatment. The aneurysm was four times larger than the caliber of the reference vessel, thus meeting the definition of a giant aneurysm. Good flow, inability to treat percutaneously and uncertainty as to its evolution called into question the need for, and appropriate timing of, surgical repair. The patient was discharged under dual antiplatelet therapy and was event-free at six-month follow-up.

Ethical disclosuresProtection of human and animal subjects

The authors declare that no experiments were performed on humans or animals for this investigation.

Confidentiality of data

The authors declare that no patient data appears in this article.

Right to privacy and informed consent

The authors declare that no patient data appears in this article.

Conflicts of interest

The authors have no conflicts of interest to declare.

Please cite this article as: Marmelo B, Delgado A, Moreira D, et al. Aneurisma gigante e intratável percutaneamente da coronária direita. Rev Port Cardiol. 2015;34:701–702.

Copyright © 2015. Sociedade Portuguesa de Cardiologia
Download PDF
Idiomas
Revista Portuguesa de Cardiologia (English edition)
Article options
Tools
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

By checking that you are a health professional, you are stating that you are aware and accept that the Portuguese Journal of Cardiology (RPC) is the Data Controller that processes the personal information of users of its website, with its registered office at Campo Grande, n.º 28, 13.º, 1700-093 Lisbon, telephone 217 970 685 and 217 817 630, fax 217 931 095, and email revista@spc.pt. I declare for all purposes that the information provided herein is accurate and correct.