Journal Information
Vol. 35. Issue 4.
Pages 241-242 (April 2016)
Share
Share
Download PDF
More article options
Vol. 35. Issue 4.
Pages 241-242 (April 2016)
Image in Cardiology
Open Access
Externalized biventricular implantable cardioverter-defibrillator
Cardioversor-desfibrilhador com ressincronização cardíaca externa
Visits
4590
Sofia Lázaro Mendes
Corresponding author
sofialazaromendes@gmail.com

Corresponding author.
, Joana Moura Ferreira, Domingos Ramos, Mariano Pêgo
Cardiology Department, Coimbra University Hospital and Medical School, Coimbra, Portugal
This item has received

Under a Creative Commons license
Article information
Full Text
Download PDF
Statistics
Figures (3)
Show moreShow less
Full Text

A 52-year-old man presented to the emergency department with externalization of a biventricular implantable cardioverter defibrillator (Figure 1). He had been admitted six months earlier with a fistula surrounding the device but left the hospital against medical advice before treatment. At admission to the emergency room his heart rate was 105 beats/min and his blood pressure was 122/96 mmHg. Cardiac auscultation revealed a systolic murmur at the apex; there were no breath sounds at the right lung base and lower limb edema was observed.

Figure 1.

Externalization of biventricular implantable cardioverter-defibrillator.

(0.23MB).

Three sets of blood cultures were drawn before antimicrobial therapy with vancomycin was begun. Methicillin-resistant Staphylococcus aureus was subsequently isolated. Transthoracic and transesophageal echocardiography were performed and a mass was seen adhering to the lead (Figures 2 and 3). Complete device and lead removal was performed within two days. The patient received parenteral antimicrobial therapy for four weeks and a new device was implanted on the contralateral side before discharge.

Figure 2.

Transthoracic echocardiogram, apical 4-chamber view, showing thickening of the lead.

(0.07MB).
Figure 3.

Transesophageal echocardiogram, showing a mass adhering to the lead.

(0.11MB).
Ethical disclosuresProtection of human and animal subjects

The authors declare that no experiments were performed on humans or animals for this study.

Confidentiality of data

The authors declare that they have followed the protocols of their work center on the publication of patient data.

Right to privacy and informed consent

The authors have obtained the written informed consent of the patients or subjects mentioned in the article. The corresponding author is in possession of this document.

Conflicts of interest

The authors have no conflicts of interest to declare.

Copyright © 2016. Sociedade Portuguesa de Cardiologia
Download PDF
Idiomas
Revista Portuguesa de Cardiologia (English edition)
Article options
Tools
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

By checking that you are a health professional, you are stating that you are aware and accept that the Portuguese Journal of Cardiology (RPC) is the Data Controller that processes the personal information of users of its website, with its registered office at Campo Grande, n.º 28, 13.º, 1700-093 Lisbon, telephone 217 970 685 and 217 817 630, fax 217 931 095, and email revista@spc.pt. I declare for all purposes that the information provided herein is accurate and correct.