Journal Information
Vol. 39. Issue 9.
Pages 547-549 (September 2020)
Share
Share
Download PDF
More article options
Vol. 39. Issue 9.
Pages 547-549 (September 2020)
Image in Cardiology
Open Access
Iatrogenic dissection of the ascending aorta after transcatheter aortic valve implantation treated conservatively
Dissecção da aorta ascendente iatrogénica após implantação de TAVI tratada de forma conservadora
Visits
2773
Pedro G. Magalhãesa,b,c,
Corresponding author
pedrogouveiamagalhaes@gmail.com

Corresponding author.
, Pieter R. Stellab, Michiel Voskuilb, Adriaan O. Kraaijeveldb
a Cardiology Department, Centro Hospitalar de Trás-os-Montes e Alto Douro, Hospital of Vila Real, Vila Real, Portugal
b Interventional Cardiology Department, Division Heart & Lungs, University Medical Center Utrecht (UMCU), Utrecht, Netherlands
c Sociedade Portuguesa de Cardiologia fellow for interventional cardiology fellowship abroad
This item has received

Under a Creative Commons license
Article information
Full Text
Download PDF
Statistics
Figures (4)
Show moreShow less
Full Text

A 90-year-old female with severe symptomatic aortic stenosis was admitted for transcatheter aortic valve implantation (TAVI). A 26-mm Edwards SAPIEN valve was implanted through a transfemoral approach. After the final aortic angiogram a subtraction image was noted from the aortic root just above the right coronary sinus (RCS) to the mid ascending aorta (Figure 1). The intracardiac echocardiogram suggested an aortic dissection, showing an enlarged ascending aorta with an intimal flap without clear flow in the false lumen (Figure 2). The hypothesis of dissection caused by a small tear at the level of the RCS was confirmed by computed tomography (CT) (Figure 3). After heart team discussion it was decided to treat the complication conservatively, since the patient had no symptoms, and she was started on labetalol. A transthoracic echocardiogram was performed that showed good valvular performance without paravalvular leakage. The patient was discharged home after two days. Three months later her exercise capacity had improved and the control CT showed resolution of the dissection (Figure 4).

Figure 1.

Aortography images: (A) after balloon valvuloplasty: * marks the probable starting point of the dissection; (B) after valve placement: subtraction image from the aortic root above the right coronary sinus to the mid ascending aorta.

(0.18MB).
Figure 2.

Intracardiac echocardiography images: (A) intimal flap dividing the aorta into a true lumen, in which the tip of the pigtail catheter can be seen (arrow), and a false lumen (*); (B) color Doppler with virtually no systolic antegrade flow in the false lumen.

(0.09MB).
Figure 3.

Contrast thoracic computed tomography images: (A) aortic dissection with the intimal tear dividing the aorta into a true lumen, fully contrasted, and a false lumen, only slightly contrasted (arrow); (B) coronal plane reconstruction similar to the aortography view showing the slightly contrasted false lumen (arrow), corresponding to the subtraction image on aortography (Figure 1B).

(0.12MB).
Figure 4.

Control contrast thoracic computed tomography images: complete resolution of the dissection in both transversal (A) and coronal (B) planes.

(0.05MB).

We believe this case highlights the importance of proper assessment of angiographic images that can prompt a search for aortic dissection using other diagnostic means.

Iatrogenic acute aortic dissection complicates 0-1.9% of TAVI cases. The best treatment remains controversial, as mortality in patients treated either with surgery (57-80%) or conservatively (58% at 30 days) is very high. Particularly in very elderly patients, a watchful waiting strategy may be reasonable, as in the case presented here.

Conflicts of interest

The authors have no conflicts of interest to declare.

Download PDF
Idiomas
Revista Portuguesa de Cardiologia (English edition)
Article options
Tools
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

By checking that you are a health professional, you are stating that you are aware and accept that the Portuguese Journal of Cardiology (RPC) is the Data Controller that processes the personal information of users of its website, with its registered office at Campo Grande, n.º 28, 13.º, 1700-093 Lisbon, telephone 217 970 685 and 217 817 630, fax 217 931 095, and email revista@spc.pt. I declare for all purposes that the information provided herein is accurate and correct.