array:26 [
  "pii" => "S2174204916302008"
  "issn" => "21742049"
  "doi" => "10.1016/j.repce.2016.07.005"
  "estado" => "S300"
  "fechaPublicacion" => "2016-12-01"
  "aid" => "896"
  "copyright" => "Sociedade Portuguesa de Cardiologia"
  "copyrightAnyo" => "2016"
  "documento" => "article"
  "crossmark" => 1
  "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
  "subdocumento" => "fla"
  "cita" => "Rev Port Cardiol. 2016;35:673-8"
  "abierto" => array:3 [
    "ES" => true
    "ES2" => true
    "LATM" => true
  ]
  "gratuito" => true
  "lecturas" => array:2 [
    "total" => 2478
    "formatos" => array:3 [
      "EPUB" => 149
      "HTML" => 1979
      "PDF" => 350
    ]
  ]
  "Traduccion" => array:1 [
    "en" => array:20 [
      "pii" => "S0870255116302268"
      "issn" => "08702551"
      "doi" => "10.1016/j.repc.2016.07.004"
      "estado" => "S300"
      "fechaPublicacion" => "2016-12-01"
      "aid" => "896"
      "copyright" => "Sociedade Portuguesa de Cardiologia"
      "documento" => "article"
      "crossmark" => 1
      "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
      "subdocumento" => "fla"
      "cita" => "Rev Port Cardiol. 2016;35:673-8"
      "abierto" => array:3 [
        "ES" => true
        "ES2" => true
        "LATM" => true
      ]
      "gratuito" => true
      "lecturas" => array:2 [
        "total" => 2556
        "formatos" => array:3 [
          "EPUB" => 177
          "HTML" => 1905
          "PDF" => 474
        ]
      ]
      "en" => array:13 [
        "idiomaDefecto" => true
        "cabecera" => "<span class="elsevierStyleTextfn">Original Article</span>"
        "titulo" => "Bailout intravenous esmolol for heart rate control in cardiac computed tomography angiography"
        "tienePdf" => "en"
        "tieneTextoCompleto" => "en"
        "tieneResumen" => array:2 [
          0 => "en"
          1 => "pt"
        ]
        "paginas" => array:1 [
          0 => array:2 [
            "paginaInicial" => "673"
            "paginaFinal" => "678"
          ]
        ]
        "titulosAlternativos" => array:1 [
          "pt" => array:1 [
            "titulo" => "Esmolol endovenoso em regime <span class="elsevierStyleItalic">bail out</span> para controlo de frequ&#234;ncia card&#237;aca na tomografia computorizada card&#237;aca"
          ]
        ]
        "contieneResumen" => array:2 [
          "en" => true
          "pt" => true
        ]
        "contieneTextoCompleto" => array:1 [
          "en" => true
        ]
        "contienePdf" => array:1 [
          "en" => true
        ]
        "resumenGrafico" => array:2 [
          "original" => 0
          "multimedia" => array:7 [
            "identificador" => "fig0015"
            "etiqueta" => "Figure 3"
            "tipo" => "MULTIMEDIAFIGURA"
            "mostrarFloat" => true
            "mostrarDisplay" => false
            "figura" => array:1 [
              0 => array:4 [
                "imagen" => "gr3.jpeg"
                "Alto" => 647
                "Ancho" => 1580
                "Tamanyo" => 44471
              ]
            ]
            "descripcion" => array:1 [
              "en" => "<p id="spar0055" class="elsevierStyleSimplePara elsevierViewall">Improvement in primary efficacy endpoint &#40;heart rate &#60;65 bpm&#41; when intravenous esmolol was added to the heart rate reduction protocol&#46; CCTA&#58; cardiac computed tomography angiography&#59; HR&#58; heart rate&#46;</p>"
            ]
          ]
        ]
        "autores" => array:1 [
          0 => array:2 [
            "autoresLista" => "S&#237;lvia Aguiar Rosa, Ruben Ramos, Hugo Marques, Rosana Santos, Cec&#237;lia Leal, Helena Casado, M&#225;rcia Saraiva, Lu&#237;sa Figueiredo, Rui Cruz Ferreira"
            "autores" => array:9 [
              0 => array:2 [
                "nombre" => "S&#237;lvia"
                "apellidos" => "Aguiar Rosa"
              ]
              1 => array:2 [
                "nombre" => "Ruben"
                "apellidos" => "Ramos"
              ]
              2 => array:2 [
                "nombre" => "Hugo"
                "apellidos" => "Marques"
              ]
              3 => array:2 [
                "nombre" => "Rosana"
                "apellidos" => "Santos"
              ]
              4 => array:2 [
                "nombre" => "Cec&#237;lia"
                "apellidos" => "Leal"
              ]
              5 => array:2 [
                "nombre" => "Helena"
                "apellidos" => "Casado"
              ]
              6 => array:2 [
                "nombre" => "M&#225;rcia"
                "apellidos" => "Saraiva"
              ]
              7 => array:2 [
                "nombre" => "Lu&#237;sa"
                "apellidos" => "Figueiredo"
              ]
              8 => array:2 [
                "nombre" => "Rui"
                "apellidos" => "Cruz Ferreira"
              ]
            ]
          ]
        ]
      ]
      "idiomaDefecto" => "en"
      "Traduccion" => array:1 [
        "en" => array:9 [
          "pii" => "S2174204916302008"
          "doi" => "10.1016/j.repce.2016.07.005"
          "estado" => "S300"
          "subdocumento" => ""
          "abierto" => array:3 [
            "ES" => true
            "ES2" => true
            "LATM" => true
          ]
          "gratuito" => true
          "lecturas" => array:1 [
            "total" => 0
          ]
          "idiomaDefecto" => "en"
          "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204916302008?idApp=UINPBA00004E"
        ]
      ]
      "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0870255116302268?idApp=UINPBA00004E"
      "url" => "/08702551/0000003500000012/v2_201701270020/S0870255116302268/v2_201701270020/en/main.assets"
    ]
  ]
  "itemSiguiente" => array:20 [
    "pii" => "S2174204916301957"
    "issn" => "21742049"
    "doi" => "10.1016/j.repce.2016.10.001"
    "estado" => "S300"
    "fechaPublicacion" => "2016-12-01"
    "aid" => "900"
    "copyright" => "Sociedade Portuguesa de Cardiologia"
    "documento" => "simple-article"
    "crossmark" => 1
    "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
    "subdocumento" => "dis"
    "cita" => "Rev Port Cardiol. 2016;35:679-80"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 2711
      "formatos" => array:3 [
        "EPUB" => 157
        "HTML" => 2042
        "PDF" => 512
      ]
    ]
    "en" => array:10 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Editorial comment</span>"
      "titulo" => "Heart rate reduction for cardiac computed tomography&#58; A necessary evil&#63;"
      "tienePdf" => "en"
      "tieneTextoCompleto" => "en"
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "679"
          "paginaFinal" => "680"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "es" => array:1 [
          "titulo" => "Redu&#231;&#227;o da frequ&#234;ncia card&#237;aca para a tomografia computorizada card&#237;aca&#58; um mal necess&#225;rio&#63;"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "en" => true
      ]
      "contienePdf" => array:1 [
        "en" => true
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "Pedro de Ara&#250;jo Gon&#231;alves"
          "autores" => array:1 [
            0 => array:2 [
              "nombre" => "Pedro"
              "apellidos" => "de Ara&#250;jo Gon&#231;alves"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "en"
    "Traduccion" => array:1 [
      "pt" => array:9 [
        "pii" => "S0870255116302347"
        "doi" => "10.1016/j.repc.2016.10.001"
        "estado" => "S300"
        "subdocumento" => ""
        "abierto" => array:3 [
          "ES" => true
          "ES2" => true
          "LATM" => true
        ]
        "gratuito" => true
        "lecturas" => array:1 [
          "total" => 0
        ]
        "idiomaDefecto" => "pt"
        "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0870255116302347?idApp=UINPBA00004E"
      ]
    ]
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204916301957?idApp=UINPBA00004E"
    "url" => "/21742049/0000003500000012/v2_201702040044/S2174204916301957/v2_201702040044/en/main.assets"
  ]
  "itemAnterior" => array:19 [
    "pii" => "S2174204916302021"
    "issn" => "21742049"
    "doi" => "10.1016/j.repce.2016.10.004"
    "estado" => "S300"
    "fechaPublicacion" => "2016-12-01"
    "aid" => "912"
    "documento" => "simple-article"
    "crossmark" => 1
    "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
    "subdocumento" => "dis"
    "cita" => "Rev Port Cardiol. 2016;35:669-71"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 2137
      "formatos" => array:3 [
        "EPUB" => 154
        "HTML" => 1509
        "PDF" => 474
      ]
    ]
    "en" => array:10 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Editorial comment</span>"
      "titulo" => "Cardiac rehabilitation in Portugal&#58; The situation in 2013-2014"
      "tienePdf" => "en"
      "tieneTextoCompleto" => "en"
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "669"
          "paginaFinal" => "671"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "pt" => array:1 [
          "titulo" => "Reabilita&#231;&#227;o card&#237;aca em Portugal&#46; Ponto da situa&#231;&#227;o em 2013-2014"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "en" => true
      ]
      "contienePdf" => array:1 [
        "en" => true
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "Miguel Mendes"
          "autores" => array:1 [
            0 => array:2 [
              "nombre" => "Miguel"
              "apellidos" => "Mendes"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "en"
    "Traduccion" => array:1 [
      "pt" => array:9 [
        "pii" => "S087025511630302X"
        "doi" => "10.1016/j.repc.2016.10.004"
        "estado" => "S300"
        "subdocumento" => ""
        "abierto" => array:3 [
          "ES" => true
          "ES2" => true
          "LATM" => true
        ]
        "gratuito" => true
        "lecturas" => array:1 [
          "total" => 0
        ]
        "idiomaDefecto" => "pt"
        "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S087025511630302X?idApp=UINPBA00004E"
      ]
    ]
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204916302021?idApp=UINPBA00004E"
    "url" => "/21742049/0000003500000012/v2_201702040044/S2174204916302021/v2_201702040044/en/main.assets"
  ]
  "asociados" => array:1 [
    0 => array:20 [
      "pii" => "S2174204916301957"
      "issn" => "21742049"
      "doi" => "10.1016/j.repce.2016.10.001"
      "estado" => "S300"
      "fechaPublicacion" => "2016-12-01"
      "aid" => "900"
      "copyright" => "Sociedade Portuguesa de Cardiologia"
      "documento" => "simple-article"
      "crossmark" => 1
      "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
      "subdocumento" => "dis"
      "cita" => "Rev Port Cardiol. 2016;35:679-80"
      "abierto" => array:3 [
        "ES" => true
        "ES2" => true
        "LATM" => true
      ]
      "gratuito" => true
      "lecturas" => array:2 [
        "total" => 2711
        "formatos" => array:3 [
          "EPUB" => 157
          "HTML" => 2042
          "PDF" => 512
        ]
      ]
      "en" => array:10 [
        "idiomaDefecto" => true
        "cabecera" => "<span class="elsevierStyleTextfn">Editorial comment</span>"
        "titulo" => "Heart rate reduction for cardiac computed tomography&#58; A necessary evil&#63;"
        "tienePdf" => "en"
        "tieneTextoCompleto" => "en"
        "paginas" => array:1 [
          0 => array:2 [
            "paginaInicial" => "679"
            "paginaFinal" => "680"
          ]
        ]
        "titulosAlternativos" => array:1 [
          "es" => array:1 [
            "titulo" => "Redu&#231;&#227;o da frequ&#234;ncia card&#237;aca para a tomografia computorizada card&#237;aca&#58; um mal necess&#225;rio&#63;"
          ]
        ]
        "contieneTextoCompleto" => array:1 [
          "en" => true
        ]
        "contienePdf" => array:1 [
          "en" => true
        ]
        "autores" => array:1 [
          0 => array:2 [
            "autoresLista" => "Pedro de Ara&#250;jo Gon&#231;alves"
            "autores" => array:1 [
              0 => array:2 [
                "nombre" => "Pedro"
                "apellidos" => "de Ara&#250;jo Gon&#231;alves"
              ]
            ]
          ]
        ]
      ]
      "idiomaDefecto" => "en"
      "Traduccion" => array:1 [
        "pt" => array:9 [
          "pii" => "S0870255116302347"
          "doi" => "10.1016/j.repc.2016.10.001"
          "estado" => "S300"
          "subdocumento" => ""
          "abierto" => array:3 [
            "ES" => true
            "ES2" => true
            "LATM" => true
          ]
          "gratuito" => true
          "lecturas" => array:1 [
            "total" => 0
          ]
          "idiomaDefecto" => "pt"
          "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0870255116302347?idApp=UINPBA00004E"
        ]
      ]
      "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204916301957?idApp=UINPBA00004E"
      "url" => "/21742049/0000003500000012/v2_201702040044/S2174204916301957/v2_201702040044/en/main.assets"
    ]
  ]
  "en" => array:19 [
    "idiomaDefecto" => true
    "cabecera" => "<span class="elsevierStyleTextfn">Original Article</span>"
    "titulo" => "Bailout intravenous esmolol for heart rate control in cardiac computed tomography angiography"
    "tieneTextoCompleto" => true
    "paginas" => array:1 [
      0 => array:2 [
        "paginaInicial" => "673"
        "paginaFinal" => "678"
      ]
    ]
    "autores" => array:1 [
      0 => array:4 [
        "autoresLista" => "S&#237;lvia Aguiar Rosa, Ruben Ramos, Hugo Marques, Rosana Santos, Cec&#237;lia Leal, Helena Casado, M&#225;rcia Saraiva, Lu&#237;sa Figueiredo, Rui Cruz Ferreira"
        "autores" => array:9 [
          0 => array:4 [
            "nombre" => "S&#237;lvia"
            "apellidos" => "Aguiar Rosa"
            "email" => array:1 [
              0 => "silviaguiarosa&#64;gmail&#46;com"
            ]
            "referencia" => array:2 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "aff0005"
              ]
              1 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">&#42;</span>"
                "identificador" => "cor0005"
              ]
            ]
          ]
          1 => array:3 [
            "nombre" => "Ruben"
            "apellidos" => "Ramos"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "aff0005"
              ]
            ]
          ]
          2 => array:3 [
            "nombre" => "Hugo"
            "apellidos" => "Marques"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">b</span>"
                "identificador" => "aff0010"
              ]
            ]
          ]
          3 => array:3 [
            "nombre" => "Rosana"
            "apellidos" => "Santos"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">b</span>"
                "identificador" => "aff0010"
              ]
            ]
          ]
          4 => array:3 [
            "nombre" => "Cec&#237;lia"
            "apellidos" => "Leal"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">b</span>"
                "identificador" => "aff0010"
              ]
            ]
          ]
          5 => array:3 [
            "nombre" => "Helena"
            "apellidos" => "Casado"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">b</span>"
                "identificador" => "aff0010"
              ]
            ]
          ]
          6 => array:3 [
            "nombre" => "M&#225;rcia"
            "apellidos" => "Saraiva"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">b</span>"
                "identificador" => "aff0010"
              ]
            ]
          ]
          7 => array:3 [
            "nombre" => "Lu&#237;sa"
            "apellidos" => "Figueiredo"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">b</span>"
                "identificador" => "aff0010"
              ]
            ]
          ]
          8 => array:3 [
            "nombre" => "Rui"
            "apellidos" => "Cruz Ferreira"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "aff0005"
              ]
            ]
          ]
        ]
        "afiliaciones" => array:2 [
          0 => array:3 [
            "entidad" => "Cardiology Department&#44; Santa Marta Hospital&#44; Lisbon&#44; Portugal"
            "etiqueta" => "a"
            "identificador" => "aff0005"
          ]
          1 => array:3 [
            "entidad" => "Radiology Department&#44; Santa Marta Hospital&#44; Lisbon&#44; Portugal"
            "etiqueta" => "b"
            "identificador" => "aff0010"
          ]
        ]
        "correspondencia" => array:1 [
          0 => array:3 [
            "identificador" => "cor0005"
            "etiqueta" => "&#8270;"
            "correspondencia" => "Corresponding author&#46;"
          ]
        ]
      ]
    ]
    "titulosAlternativos" => array:1 [
      "pt" => array:1 [
        "titulo" => "Esmolol endovenoso em regime <span class="elsevierStyleItalic">bail out</span> para controlo de frequ&#234;ncia card&#237;aca na tomografia computorizada card&#237;aca"
      ]
    ]
    "resumenGrafico" => array:2 [
      "original" => 0
      "multimedia" => array:7 [
        "identificador" => "fig0005"
        "etiqueta" => "Figure 1"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr1.jpeg"
            "Alto" => 1424
            "Ancho" => 1374
            "Tamanyo" => 109598
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0045" class="elsevierStyleSimplePara elsevierViewall">Protocol flowchart&#46; CCTA&#58; cardiac computed tomography angiography&#59; CT&#58; computed tomography&#59; HR&#58; heart rate&#59; IV&#58; intravenous&#46;</p>"
        ]
      ]
    ]
    "textoCompleto" => "<span class="elsevierStyleSections"><span id="sec0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0065">Introduction</span><p id="par0005" class="elsevierStylePara elsevierViewall">Adequate heart rate &#40;HR&#41; control is paramount for optimal cardiac imaging using single-source 64-slice multidetector computed tomography &#40;64-MSDT&#41;&#46;<a class="elsevierStyleCrossRefs" href="#bib0115"><span class="elsevierStyleSup">1&#8211;5</span></a> For these scanners&#44; HR during image acquisition should be below 65 beats per minute &#40;bpm&#41; and preferably lower than 60 bpm for optimal image quality&#46;<a class="elsevierStyleCrossRef" href="#bib0140"><span class="elsevierStyleSup">6</span></a> However&#44; commonly used pre-medication regimens with oral or intravenous metoprolol are frequently unsatisfactory&#46;<a class="elsevierStyleCrossRefs" href="#bib0145"><span class="elsevierStyleSup">7&#8211;9</span></a> Side effects&#44; including hypotension and bradycardia&#44; are also points of concern&#46;</p><p id="par0010" class="elsevierStylePara elsevierViewall">Intravenous esmolol&#44; due to its rapid onset and short half-life&#44; has been reported as a valuable option for adequate HR control&#44; either alone or in combination with oral beta-blockers&#46;<a class="elsevierStyleCrossRefs" href="#bib0160"><span class="elsevierStyleSup">10&#8211;12</span></a></p><p id="par0015" class="elsevierStylePara elsevierViewall">The aim of the present study is to evaluate the efficacy and safety of an HR reduction protocol using intravenous esmolol as bailout for failed oral metoprolol regimens in patients undergoing coronary computed tomography &#40;CT&#41; angiography &#40;CCTA&#41;&#46;</p></span><span id="sec0010" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0070">Methods</span><span id="sec0015" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0075">Study population</span><p id="par0020" class="elsevierStylePara elsevierViewall">Patients undergoing CCTA in a tertiary academic medical center between August 2011 and June 2014 were analyzed&#46; Those presenting in sinus rhythm and without contraindications for beta-blockers were included&#46; All patients had indication for coronary anatomy assessment&#46; Nineteen patients also had associated secondary indications&#58; percutaneous aortic valve implantation &#40;two&#41;&#44; paroxysmal atrial fibrillation ablation &#40;sinus rhythm during CCTA&#41; &#40;three&#41;&#44; assessment of left ventricular morphology &#40;two&#41;&#44; evaluation of valve heart disease &#40;three&#41; or ascending aorta &#40;two&#41;&#44; and morphological studies for congenital heart disease &#40;seven&#41;&#46;</p></span><span id="sec0020" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0080">Patient preparation</span><p id="par0025" class="elsevierStylePara elsevierViewall">Oral metoprolol was not used for patients presenting with HR &#60;60 bpm&#44; who proceeded directly to the CT table&#46; Individuals with baseline HR of 60-65 bpm or &#62;65 bpm received 50 mg or 100 mg oral metoprolol&#44; respectively&#46; An additional dose of 100 mg metoprolol was administered one hour later if HR was still above 65 bpm&#46; After repeated oral metoprolol administration another 60 min interval was allowed&#46; Patients were then moved to the CT table&#46; After sublingual nitrate administration and just after scouting or calcium score image acquisition &#40;<a class="elsevierStyleCrossRef" href="#fig0005">Figure 1</a>&#41;&#44; an intravenous &#40;IV&#41; bolus of esmolol 1 or 2 mg&#47;kg was administered if HR was &#62;65 bpm or &#62;70 bpm&#44; respectively&#46; A second bolus of esmolol was administered 1 min later if HR remained above 65 bpm using the same dosage&#46;</p><elsevierMultimedia ident="fig0005"></elsevierMultimedia><p id="par0030" class="elsevierStylePara elsevierViewall">Blood pressure and HR were assessed at baseline&#44; in the CT room before and after scanning&#44; and before discharge until systolic blood pressure &#40;SBP&#41; was &#62;100 mmHg and HR &#62;50 bpm or had returned to baseline&#46;</p></span><span id="sec0025" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0085">Scan protocol and image reconstruction</span><p id="par0035" class="elsevierStylePara elsevierViewall">A single scanner was used for all cases &#40;LightSpeed VCT XT&#44; GE Healthcare&#44; Milwaukee&#44; USA&#41;&#46; First&#44; unenhanced prospective heart rate-triggered axial scanning of the heart was performed for calcium scoring &#40;slice thickness 2&#46;5 mm&#59; voltage 120 kV&#44; tube current 70 mA&#59; 0&#46;35 s partial rotation&#41; just after sublingual nitrate administration&#46; In view of the requirement for esmolol administration &#40;HR on the CT table &#62;65 bpm&#41; a conservative acquisition approach was used and retrospective gating with dose modulation was selected for all these patients&#46; The contrast-enhanced scan was obtained using Visipaque&#8482; &#40;iodixanol&#41; 320 mg injected through a peripheral vein at 5 ml&#47;s followed by a saline bolus chase&#46; The scan parameters used were 0&#46;625 mm collimation&#44; rotation time 350 ms&#44; pitch adjusted to each patient&#39;s HR&#44; tube voltage 80-120 mV&#44; and effective mA 100-600&#46;</p><p id="par0040" class="elsevierStylePara elsevierViewall">Estimated effective radiation dose was calculated by applying a factor of 0&#46;014 to the volumetric CT dose&#46; Calcium scoring was included in the total effective radiation dose&#46; Electrocardiographically gated datasets were reconstructed from 40&#37; to 80&#37; of the R-R cycle length in 10&#37; increments&#46;</p></span><span id="sec0030" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0090">Endpoints</span><p id="par0045" class="elsevierStylePara elsevierViewall">The primary efficacy endpoint was HR &#60;65 bpm during contrast image acquisition and the secondary efficacy endpoint was HR &#60;60 bpm during contrast image acquisition&#46;</p><p id="par0050" class="elsevierStylePara elsevierViewall">The primary safety endpoint was symptomatic hypotension &#40;SBP &#60;90 mmHg&#41; or bradycardia &#40;heart rate &#60;45 bpm&#41; up to hospital discharge&#44; while the secondary safety endpoints were SBP &#60;90 mmHg or HR &#60;45 bpm &#40;with or without symptoms&#41; up to hospital discharge&#46;</p></span><span id="sec0035" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0095">Statistical analysis</span><p id="par0055" class="elsevierStylePara elsevierViewall">The statistical analysis was performed using IBM SPSS Statistics &#40;version 22&#59; IBM SPSS&#44; Chicago&#44; IL&#41;&#46; Continuous variables were expressed as mean &#177; standard deviation or median &#177; interquartile range&#46; Normality was tested by the Kolmogorov-Smirnov test&#46; Study group characteristics were compared using the Student&#39;s t test or the Wilcoxon-Mann-Whitney test for continuous variables&#44; and Pearson&#39;s chi-square test or Fisher&#39;s exact test for categorical measures&#44; as appropriate&#46;</p></span></span><span id="sec0040" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0100">Results</span><p id="par0060" class="elsevierStylePara elsevierViewall">Of the 947 CCTAs performed &#40;76&#37; of all CCTAs performed in the study period&#41;&#44; HR &#60;65 bpm during CCTA acquisition was achieved in 830 cases &#40;86&#37;&#41; using the oral metoprolol regimen alone&#46; Intravenous esmolol was necessary in the other 130 patients &#40;54&#37; male&#44; mean age 60&#46;9&#177;13&#46;8 years and body mass index 27&#46;40&#177;4&#46;42 kg&#47;m<span class="elsevierStyleSup">2</span>&#41; &#40;<a class="elsevierStyleCrossRef" href="#tbl0005">Table 1</a>&#41;&#46; Nearly half &#40;53&#37;&#41; of the esmolol-treated patients had been pre-medicated before admission with oral beta-blockers in accordance with the indications of the referring physician&#46;</p><elsevierMultimedia ident="tbl0005"></elsevierMultimedia><p id="par0065" class="elsevierStylePara elsevierViewall">In about one third &#40;35&#37;&#41; of esmolol-treated patients&#44; HR on presentation was &#60;60 bpm and thus they received no oral metoprolol&#44; but on the CT table HR increased to &#62;65 bpm requiring IV esmolol as per protocol&#46; The remaining 65&#37; &#40;84 patients&#41; had received in-hospital oral metoprolol &#40;mean dose 0&#46;69 mg&#47;kg&#41; according to the predefined study protocol&#46; The mean time between first oral dose of metoprolol and intravenous esmolol administration was 82&#177;39 min&#46; The mean esmolol dose administered was 1&#46;54 mg&#47;kg&#46;</p><p id="par0070" class="elsevierStylePara elsevierViewall">Initial mean HR in esmolol-treated patients was 74&#177;14 bpm&#44; which decreased to 63&#177;9 bpm during CCTA acquisition &#40;p&#60;0&#46;001&#41;&#44; corresponding to a significant mean reduction in HR of 15&#177;13&#37; &#40;<a class="elsevierStyleCrossRef" href="#fig0010">Figure 2</a>&#41;&#46; During CCTA HR variability&#44; defined as &#40;maximum HR - minimum HR&#41;&#47;mean HR&#44; was 6&#46;3&#177;7&#46;1 in esmolol patients&#46;</p><elsevierMultimedia ident="fig0010"></elsevierMultimedia><p id="par0075" class="elsevierStylePara elsevierViewall">HR &#60;65 bpm was achieved in 82 of the 130 esmolol-treated patients &#40;63&#37;&#41;&#46; Thus&#44; considering the entire CCTA population&#44; the combined metoprolol&#47;esmolol regimen led to a significant increase in the primary efficacy endpoint&#44; from 86&#37; to 95&#37; &#40;p&#60;0&#46;001&#41; &#40;<a class="elsevierStyleCrossRef" href="#fig0015">Figure 3</a>&#41;&#46;</p><elsevierMultimedia ident="fig0015"></elsevierMultimedia><p id="par0080" class="elsevierStylePara elsevierViewall">The secondary efficacy endpoint &#40;HR &#60;60 bpm&#41; was reached in 47 of the 130 esmolol patients &#40;36&#37;&#41;&#46;</p><p id="par0085" class="elsevierStylePara elsevierViewall">Four of the esmolol-treated patients &#40;3&#37;&#41; had minimum HR below 45 bpm&#46; Mean time to HR recovery to &#62;60 bpm in these patients was 37&#46;8&#177;32&#46;3 min&#46; During CCTA&#44; HR above 80 bpm was observed in five &#40;4&#37;&#41; patients&#46; Mean HR at discharge was 64&#177;7 bpm &#40;<a class="elsevierStyleCrossRef" href="#fig0010">Figure 2</a>&#41; in the esmolol group&#46;</p><p id="par0090" class="elsevierStylePara elsevierViewall">Esmolol use resulted in a significant reduction in mean SBP &#40;143&#177;21 to 115&#177;17 mmHg&#59; p&#60;0&#46;001&#41;&#46; In 11 patients &#40;8&#37;&#41; SBP decreased to levels below 90 mmHg&#46; Mean SBP at discharge was 119&#177;18 mmHg &#40;<a class="elsevierStyleCrossRef" href="#fig0020">Figure 4</a>A&#41;&#46; Initial diastolic blood pressure was 80&#177;12 mmHg&#44; decreasing to 62&#177;11 mmHg after intravenous esmolol &#40;p&#60;0&#46;001&#41;&#46; Diastolic blood pressure at discharge was 69&#177;10 mmHg &#40;<a class="elsevierStyleCrossRef" href="#fig0020">Figure 4</a>B&#41;&#46;</p><elsevierMultimedia ident="fig0020"></elsevierMultimedia><p id="par0095" class="elsevierStylePara elsevierViewall">The combined primary safety endpoint &#40;symptomatic hypotension or symptomatic bradycardia&#41; was only observed in two patients &#40;1&#46;5&#37;&#41;&#46; Both cases resolved with supine positioning&#44; intravenous fluids and atropine &#40;1 mg&#41; administration&#44; without further complications&#46;</p><p id="par0100" class="elsevierStylePara elsevierViewall">In esmolol-treated patients 113 scans &#40;87&#37;&#41; were of good image quality&#44; 10 &#40;8&#37;&#41; were of moderate quality&#44; and seven &#40;5&#37;&#41; were of poor quality and considered non-diagnostic&#46; In the latter group HR during CCTA was 75&#177;9 bpm and HR variability was 5&#46;3 &#40;42&#46;6&#41;&#46;</p><p id="par0105" class="elsevierStylePara elsevierViewall">Retrospective gating with dose modulation was selected for all esmolol-treated patient due to high baseline HR&#46; Mean estimated radiation dose was 9&#46;8&#177;10&#46;6 mSv&#46;</p></span><span id="sec0045" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0105">Discussion</span><p id="par0110" class="elsevierStylePara elsevierViewall">HR while scanning should be less than 65 bpm and ideally less than 60 bpm for optimal image quality when a 64-slice MDCT scanner is to be used&#46;<a class="elsevierStyleCrossRef" href="#bib0140"><span class="elsevierStyleSup">6</span></a> Despite this recommendation&#44; in 2007 an American survey showed that there were differences in beta-blocker protocols and that a cutoff higher than 65 bpm was used by 80&#37; of centers&#46;<a class="elsevierStyleCrossRef" href="#bib0175"><span class="elsevierStyleSup">13</span></a></p><p id="par0115" class="elsevierStylePara elsevierViewall">Metoprolol is the most common beta-blocker agent used to achieve HR control during CCTA&#46; However&#44; due to its low oral bioavailability&#44; variable metabolism and inter-subject variability&#44; the results are often suboptimal&#46; This has led to the use of several alternate regimens including intravenous metoprolol&#44; other beta-blockers such as atenolol&#44; ivabradine&#44; or calcium channel blockers&#46;<a class="elsevierStyleCrossRefs" href="#bib0180"><span class="elsevierStyleSup">14&#44;15</span></a> Nevertheless intravenous metoprolol&#44; the most commonly used parenteral beta-blocker&#44; has demonstrated limited efficacy in lowering HR&#46;</p><p id="par0120" class="elsevierStylePara elsevierViewall">Ivabradine has been suggested as an alternative to beta-blockers&#46; Regimens of oral ivabradine proved more effective in reducing HR than oral metoprolol<a class="elsevierStyleCrossRef" href="#bib0190"><span class="elsevierStyleSup">16</span></a> and an intravenous protocol demonstrated efficacy and safety in patients ineligible for intravenous beta-blockers&#46;<a class="elsevierStyleCrossRef" href="#bib0195"><span class="elsevierStyleSup">17</span></a></p><p id="par0125" class="elsevierStylePara elsevierViewall">Esmolol may be at least as efficacious as intravenous metoprolol to achieve optimal HR&#46;<a class="elsevierStyleCrossRef" href="#bib0170"><span class="elsevierStyleSup">12</span></a> However&#44; to our knowledge there are no studies reporting on esmolol use as bailout when previous oral HR regimens have failed&#46;</p><p id="par0130" class="elsevierStylePara elsevierViewall">In our study the oral metoprolol regimen used enabled 86&#37; of patients to achieve target HR &#60;65 bpm&#46; This percentage is higher than described in previous studies&#46; De Graaf et al&#46; demonstrated optimal beta-blockade in 73&#37; of CCTA patients using oral metoprolol&#46;<a class="elsevierStyleCrossRef" href="#bib0200"><span class="elsevierStyleSup">18</span></a> Intravenous metoprolol&#44; also commonly used&#44; again demonstrated limited efficacy in lowering HR&#46; In a study by Jimenez-Juan et al&#46; only 42&#37; of patients who did not achieve HR &#60;60 bpm with oral metoprolol reached target HR with additional intravenous metoprolol&#46;<a class="elsevierStyleCrossRef" href="#bib0205"><span class="elsevierStyleSup">19</span></a> These findings highlight the need for a more effective protocol for HR control&#46; In addition&#44; the rapid action and short half-life of esmolol make it an attractive drug in this setting&#46; Similarly to data reported by Degertekin et al&#46;&#44;<a class="elsevierStyleCrossRef" href="#bib0160"><span class="elsevierStyleSup">10</span></a> in our study bolus esmolol produced HR below 65 bpm in 63&#37; &#40;82&#47;130&#41; of patients&#46; Thus&#44; the introduction of bailout intravenous esmolol enabled 95&#37; of the entire cohort to be imaged with HR below 65 bpm&#46; The mean HR reduction was 11 bpm&#44; 4&#37; of patients were imaged with HR greater than 80 bpm and only 5&#37; of CCTA exams were considered to be non-diagnostic&#46;</p><p id="par0135" class="elsevierStylePara elsevierViewall">Our study suggests that despite an aggressive beta-blocker strategy&#44; the risk of side effects was relatively small&#46; Only 1&#46;5&#37; of patients had symptomatic hypotension or bradycardia&#46; Wang et al&#46; reported 0&#46;4&#37; incidence of adverse events in a Chinese population treated with intravenous esmolol only&#46;<a class="elsevierStyleCrossRef" href="#bib0165"><span class="elsevierStyleSup">11</span></a> In our cohort&#44; however&#44; esmolol was used on top of oral metoprolol in 64&#37; of cases&#44; which could explain the higher incidence of side effects&#46; Contraindications for beta-blockers are often considered a limitation for CCTA in patients with relatively high HR&#46; Esmolol&#39;s short half-life could make it useful for patients who cannot tolerate prolonged beta-blockade&#46;</p><p id="par0140" class="elsevierStylePara elsevierViewall">We reported a higher effective radiation dose than some real-world registries&#46;<a class="elsevierStyleCrossRef" href="#bib0210"><span class="elsevierStyleSup">20</span></a> Unlike these studies&#44; in which both prospective and retrospective acquisition protocols are reported&#44; herein we report on a specific population subset in which only a retrospective acquisition protocol was chosen for all patients &#40;because of high baseline HR&#41;&#46; Also&#44; in our registry about 15&#37; of esmolol-treated patients had secondary indications for scanning&#44; such as study for transcatheter aortic valve implantation&#44; in which the scan range is significantly greater&#46;</p><p id="par0145" class="elsevierStylePara elsevierViewall">The introduction of high temporal resolution &#40;83 ms&#41; dual-source CT in clinical practice in 2005 has enabled high image quality diagnostic CCTA studies at increased HR with less dependency on HR lowering agents&#46;<a class="elsevierStyleCrossRef" href="#bib0215"><span class="elsevierStyleSup">21</span></a> However&#44; the latest generation of dual-source scanners has introduced a new scan mode&#44; prospectively ECG-triggered helical data acquisition with very high pitch values&#46; The high pitch enables acquisition with very low radiation exposure &#40;&#60;1 mSv&#41; but low and regular HR is critical for this technique&#46; Consequently&#44; effective HR reduction strategies are yet again pivotal if such very low dose acquisition protocols are to be followed&#46;<a class="elsevierStyleCrossRef" href="#bib0220"><span class="elsevierStyleSup">22</span></a></p></span><span id="sec0050" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0110">Study limitations</span><p id="par0150" class="elsevierStylePara elsevierViewall">This is a retrospective study with inherent limitations including potential selection bias&#46; However&#44; the HR control protocol was prospectively designed and uniformly applied to all eligible patients&#46; Also&#44; this was a single-center experience with a relatively small sample of esmolol-treated patients&#46; Larger multicenter trials using placebo or intravenous metoprolol as active controls will be needed to clearly establish the role of intravenous esmolol in this setting&#46;</p></span><span id="sec0055" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0115">Conclusion</span><p id="par0155" class="elsevierStylePara elsevierViewall">Despite optimal use of oral metoprolol for HR control before CCTA&#44; 14&#37; of cases still required intravenous esmolol for HR control&#46; Bailout administration of intravenous esmolol on the CT table was safe and effective and enabled 95&#37; of patients to be imaged with HR below 65 bpm&#46;</p></span><span id="sec0060" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0120">Ethical disclosures</span><span id="sec0065" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0125">Protection of human and animal subjects</span><p id="par0160" class="elsevierStylePara elsevierViewall">The authors declare that no experiments were performed on humans or animals for this study&#46;</p></span><span id="sec0070" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0130">Confidentiality of data</span><p id="par0165" class="elsevierStylePara elsevierViewall">The authors declare that they have followed the protocols of their work center on the publication of patient data&#46;</p></span><span id="sec0075" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0135">Right to privacy and informed consent</span><p id="par0170" class="elsevierStylePara elsevierViewall">The authors have obtained the written informed consent of the patients or subjects mentioned in the article&#46; The corresponding author is in possession of this document&#46;</p></span></span><span id="sec0080" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0140">Conflicts of interest</span><p id="par0175" class="elsevierStylePara elsevierViewall">The authors have no conflicts of interest to declare&#46;</p></span></span>"
    "textoCompletoSecciones" => array:1 [
      "secciones" => array:13 [
        0 => array:3 [
          "identificador" => "xres798192"
          "titulo" => "Abstract"
          "secciones" => array:4 [
            0 => array:2 [
              "identificador" => "abst0005"
              "titulo" => "Objective"
            ]
            1 => array:2 [
              "identificador" => "abst0010"
              "titulo" => "Methods"
            ]
            2 => array:2 [
              "identificador" => "abst0015"
              "titulo" => "Results"
            ]
            3 => array:2 [
              "identificador" => "abst0020"
              "titulo" => "Conclusion"
            ]
          ]
        ]
        1 => array:2 [
          "identificador" => "xpalclavsec796161"
          "titulo" => "Keywords"
        ]
        2 => array:3 [
          "identificador" => "xres798191"
          "titulo" => "Resumo"
          "secciones" => array:4 [
            0 => array:2 [
              "identificador" => "abst0025"
              "titulo" => "Objetivo"
            ]
            1 => array:2 [
              "identificador" => "abst0030"
              "titulo" => "M&#233;todos"
            ]
            2 => array:2 [
              "identificador" => "abst0035"
              "titulo" => "Resultados"
            ]
            3 => array:2 [
              "identificador" => "abst0040"
              "titulo" => "Conclus&#227;o"
            ]
          ]
        ]
        3 => array:2 [
          "identificador" => "xpalclavsec796160"
          "titulo" => "Palavras-chave"
        ]
        4 => array:2 [
          "identificador" => "sec0005"
          "titulo" => "Introduction"
        ]
        5 => array:3 [
          "identificador" => "sec0010"
          "titulo" => "Methods"
          "secciones" => array:5 [
            0 => array:2 [
              "identificador" => "sec0015"
              "titulo" => "Study population"
            ]
            1 => array:2 [
              "identificador" => "sec0020"
              "titulo" => "Patient preparation"
            ]
            2 => array:2 [
              "identificador" => "sec0025"
              "titulo" => "Scan protocol and image reconstruction"
            ]
            3 => array:2 [
              "identificador" => "sec0030"
              "titulo" => "Endpoints"
            ]
            4 => array:2 [
              "identificador" => "sec0035"
              "titulo" => "Statistical analysis"
            ]
          ]
        ]
        6 => array:2 [
          "identificador" => "sec0040"
          "titulo" => "Results"
        ]
        7 => array:2 [
          "identificador" => "sec0045"
          "titulo" => "Discussion"
        ]
        8 => array:2 [
          "identificador" => "sec0050"
          "titulo" => "Study limitations"
        ]
        9 => array:2 [
          "identificador" => "sec0055"
          "titulo" => "Conclusion"
        ]
        10 => array:3 [
          "identificador" => "sec0060"
          "titulo" => "Ethical disclosures"
          "secciones" => array:3 [
            0 => array:2 [
              "identificador" => "sec0065"
              "titulo" => "Protection of human and animal subjects"
            ]
            1 => array:2 [
              "identificador" => "sec0070"
              "titulo" => "Confidentiality of data"
            ]
            2 => array:2 [
              "identificador" => "sec0075"
              "titulo" => "Right to privacy and informed consent"
            ]
          ]
        ]
        11 => array:2 [
          "identificador" => "sec0080"
          "titulo" => "Conflicts of interest"
        ]
        12 => array:1 [
          "titulo" => "References"
        ]
      ]
    ]
    "pdfFichero" => "main.pdf"
    "tienePdf" => true
    "fechaRecibido" => "2016-02-09"
    "fechaAceptado" => "2016-07-08"
    "PalabrasClave" => array:2 [
      "en" => array:1 [
        0 => array:4 [
          "clase" => "keyword"
          "titulo" => "Keywords"
          "identificador" => "xpalclavsec796161"
          "palabras" => array:3 [
            0 => "Coronary computed tomography angiography"
            1 => "Esmolol"
            2 => "Heart rate control"
          ]
        ]
      ]
      "pt" => array:1 [
        0 => array:4 [
          "clase" => "keyword"
          "titulo" => "Palavras-chave"
          "identificador" => "xpalclavsec796160"
          "palabras" => array:3 [
            0 => "Angiografia coron&#225;ria por tomografia computorizada"
            1 => "Esmolol"
            2 => "Controlo de frequ&#234;ncia card&#237;aca"
          ]
        ]
      ]
    ]
    "tieneResumen" => true
    "resumen" => array:2 [
      "en" => array:3 [
        "titulo" => "Abstract"
        "resumen" => "<span id="abst0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0010">Objective</span><p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">To evaluate the efficacy and safety of a heart rate &#40;HR&#41; reduction protocol using intravenous esmolol as bailout for failed oral metoprolol regimens in patients undergoing coronary computed tomography angiography &#40;CCTA&#41; with 64-slice multidetector computed tomography &#40;64-MDCT&#41;&#46;</p></span> <span id="abst0010" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0015">Methods</span><p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">Patients who underwent cardiac 64-MDCT in a single institution between 2011 and 2014 were analyzed&#46; Those with HR above 60 beats per minute &#40;bpm&#41; on presentation received oral metoprolol &#40;50-200 mg&#41; at least one hour before CCTA&#46; Intravenous esmolol 1-2 mg&#47;kg was administered as a bolus whenever HR remained over 65 bpm just before imaging&#46; The primary efficacy endpoint was HR &#60;65 bpm during CCTA&#46; The primary safety endpoint was symptomatic hypotension or bradycardia up to hospital discharge&#46;</p></span> <span id="abst0015" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0020">Results</span><p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">During the study period CCTA was performed in 947 cases&#46; In 86&#37; of these&#44; oral metoprolol was the only medication required to successfully reduce HR &#60;60 bpm&#46; Esmolol was used in the remaining 130 patients &#40;14&#37;&#41;&#46; For esmolol-treated patients mean baseline and acquisition HR were 74&#177;14 bpm and 63&#177;9 bpm&#44; respectively &#40;p&#60;0&#46;001&#41;&#46; The target HR of &#60;65 bpm was achieved in 82 of the 130 esmolol-treated patients &#40;63&#37;&#41;&#46; Considering the whole population&#44; esmolol use led to a significant increase in the primary efficacy endpoint from 86&#37; to 95&#37; &#40;p&#60;0&#46;001&#41;&#46; Esmolol also resulted in a statistically&#44; but not clinically&#44; significant reduction in systolic blood pressure &#40;144&#177;22 to 115&#177;17 mmHg&#59; p&#60;0&#46;001&#41;&#46; The combined primary safety endpoint was only observed in two &#40;1&#46;5&#37;&#41; patients&#46;</p></span> <span id="abst0020" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0025">Conclusion</span><p id="spar0020" class="elsevierStyleSimplePara elsevierViewall">Despite optimal use of oral beta-blockers&#44; 14&#37; of patients needed intravenous esmolol for HR control&#46; The pre-medication combination of oral metoprolol and on-demand administration of intravenous esmolol was safe and effective and enabled 95&#37; of patients to be imaged with HR below 65 bpm&#46;</p></span>"
        "secciones" => array:4 [
          0 => array:2 [
            "identificador" => "abst0005"
            "titulo" => "Objective"
          ]
          1 => array:2 [
            "identificador" => "abst0010"
            "titulo" => "Methods"
          ]
          2 => array:2 [
            "identificador" => "abst0015"
            "titulo" => "Results"
          ]
          3 => array:2 [
            "identificador" => "abst0020"
            "titulo" => "Conclusion"
          ]
        ]
      ]
      "pt" => array:3 [
        "titulo" => "Resumo"
        "resumen" => "<span id="abst0025" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0035">Objetivo</span><p id="spar0025" class="elsevierStyleSimplePara elsevierViewall">Avaliar a efic&#225;cia e seguran&#231;a de um protocolo de redu&#231;&#227;o de frequ&#234;ncia card&#237;aca &#40;FC&#41; utilizando esmolol endovenoso ap&#243;s fal&#234;ncia de metoprolol oral&#44; em doentes submetidos a angiografia coron&#225;ria por tomografia computorizada &#40;CCTA&#41; de 64 cortes&#46;</p></span> <span id="abst0030" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0040">M&#233;todos</span><p id="spar0030" class="elsevierStyleSimplePara elsevierViewall">De 2011 a 2014 foram avaliados os indiv&#237;duos submetidos a CCTA num &#250;nico centro&#46; Os indiv&#237;duos com FC &#62;60 bpm &#224; admiss&#227;o receberam 50-200 mg de metoprolol oral pelo menos uma hora antes da CCTA&#46; Esmolol endovenoso em b&#243;lus &#40;1-2 mg&#47;kg&#41; foi administrado se FC &#62;65 bpm imediatamente antes da aquisi&#231;&#227;o de imagem&#46; O <span class="elsevierStyleItalic">endpoint</span> prim&#225;rio de efic&#225;cia foi FC &#60;65 bpm durante a aquisi&#231;&#227;o de imagem com contraste&#46; O <span class="elsevierStyleItalic">endpoint</span> prim&#225;rio de seguran&#231;a foi hipotens&#227;o ou bradicardia sintom&#225;tica durante a perman&#234;ncia no hospital&#46;</p></span> <span id="abst0035" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0045">Resultados</span><p id="spar0035" class="elsevierStyleSimplePara elsevierViewall">Foram efetuadas 947 CCTA durante o per&#237;odo de estudo&#46; Em 86&#37; dos casos&#44; metoprolol oral foi o &#250;nico f&#225;rmaco utilizado&#46; Foi necess&#225;ria a administra&#231;&#227;o de esmolol em 130 &#40;14&#37;&#41; doentes&#46; Nos doentes que receberam esmolol&#44; a FC basal reduziu em m&#233;dia de 74&#177;14 bpm para 63&#177;9 bpm &#40;p&#60;0&#44;001&#41;&#46; O objetivo prim&#225;rio de FC &#60;65 bpm foi alcan&#231;ado em 82 desses 130 doentes &#40;63&#37;&#41;&#46; Considerando toda a popula&#231;&#227;o&#44; o recurso a esmolol permitiu um aumento significativo da propor&#231;&#227;o de CCTA realizados com FC &#60;65 bpm &#40;86&#37; para 95&#37; &#91;p&#60;0&#44;001&#93;&#41;&#46; A administra&#231;&#227;o de esmolol esteve associada a redu&#231;&#227;o estatisticamente&#44; mas n&#227;o clinicamente&#44; significativa da press&#227;o arterial sist&#243;lica &#40;144&#177;22 para 115&#177;17 mmHg&#59; p&#60;0&#44;001&#41;&#46; O <span class="elsevierStyleItalic">endpoint</span> combinado de seguran&#231;a foi observado em dois &#40;1&#44;5&#37;&#41; dos doentes&#46;</p></span> <span id="abst0040" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0050">Conclus&#227;o</span><p id="spar0040" class="elsevierStyleSimplePara elsevierViewall">Apesar da utiliza&#231;&#227;o sistem&#225;tica de betabloqueante oral&#44; 14&#37; dos casos necessitaram de esmolol endovenoso para controlo adequado de FC&#46; Pr&#233;-medica&#231;&#227;o combinada de metoprolol oral e esmolol endovenoso quando necess&#225;ria foi segura e eficaz&#44; e permitiu que 95&#37; dos doentes apresentassem FC &#60;65 bpm no momento da aquisi&#231;&#227;o de imagem&#46;</p></span>"
        "secciones" => array:4 [
          0 => array:2 [
            "identificador" => "abst0025"
            "titulo" => "Objetivo"
          ]
          1 => array:2 [
            "identificador" => "abst0030"
            "titulo" => "M&#233;todos"
          ]
          2 => array:2 [
            "identificador" => "abst0035"
            "titulo" => "Resultados"
          ]
          3 => array:2 [
            "identificador" => "abst0040"
            "titulo" => "Conclus&#227;o"
          ]
        ]
      ]
    ]
    "multimedia" => array:5 [
      0 => array:7 [
        "identificador" => "fig0005"
        "etiqueta" => "Figure 1"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr1.jpeg"
            "Alto" => 1424
            "Ancho" => 1374
            "Tamanyo" => 109598
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0045" class="elsevierStyleSimplePara elsevierViewall">Protocol flowchart&#46; CCTA&#58; cardiac computed tomography angiography&#59; CT&#58; computed tomography&#59; HR&#58; heart rate&#59; IV&#58; intravenous&#46;</p>"
        ]
      ]
      1 => array:7 [
        "identificador" => "fig0010"
        "etiqueta" => "Figure 2"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr2.jpeg"
            "Alto" => 646
            "Ancho" => 971
            "Tamanyo" => 37918
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0050" class="elsevierStyleSimplePara elsevierViewall">Changes in heart rate after esmolol administration&#46; HR&#58; heart rate&#46;</p>"
        ]
      ]
      2 => array:7 [
        "identificador" => "fig0015"
        "etiqueta" => "Figure 3"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr3.jpeg"
            "Alto" => 385
            "Ancho" => 949
            "Tamanyo" => 33113
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0055" class="elsevierStyleSimplePara elsevierViewall">Improvement in primary efficacy endpoint &#40;heart rate &#60;65 bpm&#41; when intravenous esmolol was added to the heart rate reduction protocol&#46; CCTA&#58; cardiac computed tomography angiography&#59; HR&#58; heart rate&#46;</p>"
        ]
      ]
      3 => array:7 [
        "identificador" => "fig0020"
        "etiqueta" => "Figure 4"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr4.jpeg"
            "Alto" => 542
            "Ancho" => 1631
            "Tamanyo" => 59413
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0060" class="elsevierStyleSimplePara elsevierViewall">Changes in &#40;A&#41; systolic and &#40;B&#41; diastolic blood pressure after esmolol administration&#46;</p>"
        ]
      ]
      4 => array:8 [
        "identificador" => "tbl0005"
        "etiqueta" => "Table 1"
        "tipo" => "MULTIMEDIATABLA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "detalles" => array:1 [
          0 => array:3 [
            "identificador" => "at1"
            "detalle" => "Table "
            "rol" => "short"
          ]
        ]
        "tabla" => array:2 [
          "leyenda" => "<p id="spar0070" class="elsevierStyleSimplePara elsevierViewall">BMI&#58; body mass index&#59; CABG&#58; coronary artery bypass grafting&#59; MI&#58; myocardial infarction&#59; PCI&#58; percutaneous coronary intervention&#46;</p>"
          "tablatextoimagen" => array:1 [
            0 => array:2 [
              "tabla" => array:1 [
                0 => """
                  <table border="0" frame="\n
                  \t\t\t\t\tvoid\n
                  \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><th class="td" title="table-head  " align="" valign="top" scope="col" style="border-bottom: 2px solid black">&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="left" valign="top" scope="col" style="border-bottom: 2px solid black">Esmolol&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="left" valign="top" scope="col" style="border-bottom: 2px solid black">No esmolol&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Age &#40;years&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">60&#46;9&#177;13&#46;8&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">61&#46;5&#177;13&#46;7&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Male&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">54&#46;0&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">52&#46;9&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Weight &#40;kg&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">73&#46;9&#177;13&#46;7&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">75&#46;4&#177;14&#46;3&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">BMI &#40;kg&#47;m<span class="elsevierStyleSup">2</span>&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">27&#46;40&#177;4&#46;42&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">23&#46;7&#177;2&#46;7&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Hypertension&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">69&#46;6&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">73&#46;5&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Diabetes&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">27&#46;7&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">26&#46;5&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Dyslipidemia&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">68&#46;6&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">66&#46;9&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Current smoker&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">14&#46;5&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">12&#46;5&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Previous MI&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">18&#46;7&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">12&#46;5&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Previous PCI&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">17&#46;9&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">14&#46;0&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Previous CABG&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">16&#46;9&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">8&#46;1&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Previous beta-blockers&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">55&#46;3&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">45&#46;6&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr></tbody></table>
                  """
              ]
              "imagenFichero" => array:1 [
                0 => "xTab1338723.png"
              ]
            ]
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0065" class="elsevierStyleSimplePara elsevierViewall">Clinical characteristics of patients receiving and not receiving esmolol&#46;</p>"
        ]
      ]
    ]
    "bibliografia" => array:2 [
      "titulo" => "References"
      "seccion" => array:1 [
        0 => array:2 [
          "identificador" => "bibs0005"
          "bibliografiaReferencia" => array:22 [
            0 => array:3 [
              "identificador" => "bib0115"
              "etiqueta" => "1"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Noninvasive coronary angiography with 64-section CT&#58; effect of average heart rate and heart rate variability on image quality"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "S&#46; Leschka"
                            1 => "S&#46; Wildermuth"
                            2 => "T&#46; Boehm"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1148/radiol.2412051384"
                      "Revista" => array:6 [
                        "tituloSerie" => "Radiology"
                        "fecha" => "2006"
                        "volumen" => "241"
                        "paginaInicial" => "378"
                        "paginaFinal" => "385"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/16966483"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            1 => array:3 [
              "identificador" => "bib0120"
              "etiqueta" => "2"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Noninvasive coronary angiography using 64-slice spiral computed tomography in an unselected patient collective&#58; effect of heart rate&#44; heart rate variability and coronary calcifications on image quality and diagnostic accuracy"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "H&#46; Brodoefel"
                            1 => "A&#46; Reimann"
                            2 => "C&#46; Burgstahler"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.ejrad.2007.05.013"
                      "Revista" => array:6 [
                        "tituloSerie" => "Eur J Radiol"
                        "fecha" => "2008"
                        "volumen" => "66"
                        "paginaInicial" => "134"
                        "paginaFinal" => "141"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/17600648"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            2 => array:3 [
              "identificador" => "bib0125"
              "etiqueta" => "3"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Noninvasive coronary angiography with 16-detector row CT&#58; effect of heart rate"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "M&#46;H&#46; Hoffmann"
                            1 => "H&#46; Shi"
                            2 => "R&#46; Manzke"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1148/radiol.2341031408"
                      "Revista" => array:6 [
                        "tituloSerie" => "Radiology"
                        "fecha" => "2005"
                        "volumen" => "234"
                        "paginaInicial" => "86"
                        "paginaFinal" => "97"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/15550373"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            3 => array:3 [
              "identificador" => "bib0130"
              "etiqueta" => "4"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Contraindications and side effects of commonly used medications in coronary CT angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "M&#46; Khan"
                            1 => "K&#46;W&#46; Cummings"
                            2 => "F&#46;R&#46; Gutierrez"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1007/s10554-010-9654-8"
                      "Revista" => array:6 [
                        "tituloSerie" => "Int J Cardiovasc Imaging"
                        "fecha" => "2011"
                        "volumen" => "27"
                        "paginaInicial" => "441"
                        "paginaFinal" => "449"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20571874"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            4 => array:3 [
              "identificador" => "bib0135"
              "etiqueta" => "5"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Improvement of image quality with beta-blocker premedication on ECG-gated 16-MDCT coronary angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "S&#46;S&#46; Shim"
                            1 => "Y&#46; Kim"
                            2 => "S&#46;M&#46; Lim"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.2214/ajr.184.2.01840649"
                      "Revista" => array:6 [
                        "tituloSerie" => "AJR Am J Roentgenol"
                        "fecha" => "2005"
                        "volumen" => "184"
                        "paginaInicial" => "649"
                        "paginaFinal" => "654"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/15671392"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            5 => array:3 [
              "identificador" => "bib0140"
              "etiqueta" => "6"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography&#58; experience in 94 patients"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "S&#46; Schroeder"
                            1 => "A&#46;F&#46; Kopp"
                            2 => "A&#46; Kuettner"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Clin Imaging"
                        "fecha" => "2002"
                        "volumen" => "26"
                        "paginaInicial" => "106"
                        "paginaFinal" => "111"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11852217"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            6 => array:3 [
              "identificador" => "bib0145"
              "etiqueta" => "7"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Safety&#44; efficacy&#44; and indications of beta-adrenergic receptor blockade to reduce heart rate prior to coronary CT angiography"
                      "autores" => array:1 [
                        0 => array:3 [
                          "colaboracion" => "Working group &#8220;Cardiac CT&#8221; of the German Cardiac Society"
                          "etal" => true
                          "autores" => array:3 [
                            0 => "A&#46;A&#46; Mahabadi"
                            1 => "S&#46; Achenbach"
                            2 => "C&#46; Burgstahler"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1148/radiol.10100140"
                      "Revista" => array:6 [
                        "tituloSerie" => "Radiology"
                        "fecha" => "2010"
                        "volumen" => "257"
                        "paginaInicial" => "614"
                        "paginaFinal" => "623"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/21084413"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            7 => array:3 [
              "identificador" => "bib0150"
              "etiqueta" => "8"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Efficacy of pre-scan beta-blockade and impact of heart rate on image quality in patients undergoing coronary multidetector computed tomography angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "M&#46;D&#46; Shapiro"
                            1 => "A&#46;J&#46; Pena"
                            2 => "J&#46;H&#46; Nichols"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.ejrad.2007.05.006"
                      "Revista" => array:6 [
                        "tituloSerie" => "Eur J Radiol"
                        "fecha" => "2008"
                        "volumen" => "66"
                        "paginaInicial" => "37"
                        "paginaFinal" => "41"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/17587526"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            8 => array:3 [
              "identificador" => "bib0155"
              "etiqueta" => "9"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Evaluation of the effectiveness of oral beta-blockade in patients for coronary computed tomographic angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "H&#46;K&#46; Pannu"
                            1 => "C&#46; Sullivan"
                            2 => "S&#46; Lai"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1097/RCT.0b013e318075e759"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Comput Assist Tomogr"
                        "fecha" => "2008"
                        "volumen" => "32"
                        "paginaInicial" => "247"
                        "paginaFinal" => "251"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18379311"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            9 => array:3 [
              "identificador" => "bib0160"
              "etiqueta" => "10"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Safety and efficacy of patient preparation with intravenous esmolol before 64-slice computed tomography coronary angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "M&#46; Degertekin"
                            1 => "G&#46; Gemici"
                            2 => "Z&#46; Kaya"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1097/MCA.0b013e3282f27c20"
                      "Revista" => array:6 [
                        "tituloSerie" => "Coron Artery Dis"
                        "fecha" => "2008"
                        "volumen" => "19"
                        "paginaInicial" => "33"
                        "paginaFinal" => "36"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18281813"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            10 => array:3 [
              "identificador" => "bib0165"
              "etiqueta" => "11"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Safety and efficacy of intravenous esmolol before prospective electrocardiogram-triggered high-pitch spiral acquisition for computed tomography coronary angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "J&#46;D&#46; Wang"
                            1 => "H&#46;W&#46; Zhang"
                            2 => "Q&#46; Xin"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.3969/j.issn.1671-5411.2014.01.011"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Geriatr Cardiol"
                        "fecha" => "2014"
                        "volumen" => "11"
                        "paginaInicial" => "39"
                        "paginaFinal" => "43"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24748880"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            11 => array:3 [
              "identificador" => "bib0170"
              "etiqueta" => "12"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Esmolol is noninferior to metoprolol in achieving a target heart rate of 65 beats&#47;min in patients referred to coronary CT angiography&#58; a randomized controlled clinical trial"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "P&#46; Maurovich-Horvat"
                            1 => "M&#46; K&#225;rolyi"
                            2 => "T&#46; Horv&#225;th"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.jcct.2015.02.001"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Cardiovasc Comput Tomogr"
                        "fecha" => "2015"
                        "volumen" => "9"
                        "paginaInicial" => "139"
                        "paginaFinal" => "145"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25819196"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            12 => array:3 [
              "identificador" => "bib0175"
              "etiqueta" => "13"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "64-MDCT angiography of the coronary arteries&#58; nationwide survey of patient preparation practice"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "P&#46;T&#46; Johnson"
                            1 => "J&#46; Eng"
                            2 => "H&#46;K&#46; Pannu"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.2214/AJR.07.2620"
                      "Revista" => array:6 [
                        "tituloSerie" => "AJR Am J Roentgenol"
                        "fecha" => "2008"
                        "volumen" => "190"
                        "paginaInicial" => "743"
                        "paginaFinal" => "747"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18287447"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            13 => array:3 [
              "identificador" => "bib0180"
              "etiqueta" => "14"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "High-dose intravenous metoprolol usage for reducing heart rate at CT coronary angiography&#58; efficacy and safety"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "V&#46;M&#46; Raju"
                            1 => "O&#46;E&#46; Gosling"
                            2 => "G&#46; Morgan-Hughes"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.crad.2014.03.003"
                      "Revista" => array:6 [
                        "tituloSerie" => "Clin Radiol"
                        "fecha" => "2014"
                        "volumen" => "69"
                        "paginaInicial" => "739"
                        "paginaFinal" => "744"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24824980"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            14 => array:3 [
              "identificador" => "bib0185"
              "etiqueta" => "15"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "&#8220;In-house&#8221; pharmacological management for computed tomography coronary angiography&#58; heart rate reduction&#44; timing and safety of different drugs used during patient preparation"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "E&#46; Maffei"
                            1 => "A&#46;A&#46; Palumbo"
                            2 => "C&#46; Martini"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1007/s00330-009-1509-0"
                      "Revista" => array:6 [
                        "tituloSerie" => "Eur Radiol"
                        "fecha" => "2009"
                        "volumen" => "19"
                        "paginaInicial" => "2931"
                        "paginaFinal" => "2940"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/19597820"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            15 => array:3 [
              "identificador" => "bib0190"
              "etiqueta" => "16"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Safety and efficacy of oral ivabradine as a heart rate-reducing agent in patients undergoing CT coronary angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "K&#46;K&#46; Adile"
                            1 => "A&#46; Kapoor"
                            2 => "S&#46;K&#46; Jain"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1259/bjr/22102914"
                      "Revista" => array:6 [
                        "tituloSerie" => "Br J Radiol"
                        "fecha" => "2012"
                        "volumen" => "85"
                        "paginaInicial" => "e424"
                        "paginaFinal" => "e428"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22815422"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            16 => array:3 [
              "identificador" => "bib0195"
              "etiqueta" => "17"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Intravenous ivabradine for control of heart rate during coronary CT angiography&#58; a randomized&#44; double-blind&#44; placebo-controlled trial"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "F&#46; Cademartiri"
                            1 => "J&#46; Garot"
                            2 => "M&#46; Tendera"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.jcct.2015.04.005"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Cardiovasc Comput Tomogr"
                        "fecha" => "2015"
                        "volumen" => "9"
                        "paginaInicial" => "286"
                        "paginaFinal" => "294"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26088378"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            17 => array:3 [
              "identificador" => "bib0200"
              "etiqueta" => "18"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Evaluation of contraindications and efficacy of oral beta blockade before computed tomographic coronary angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "F&#46;R&#46; de Graaf"
                            1 => "J&#46;D&#46; Schuijf"
                            2 => "J&#46;E&#46; van Velzen"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.amjcard.2009.10.058"
                      "Revista" => array:6 [
                        "tituloSerie" => "Am J Cardiol"
                        "fecha" => "2010"
                        "volumen" => "105"
                        "paginaInicial" => "767"
                        "paginaFinal" => "772"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20211317"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            18 => array:3 [
              "identificador" => "bib0205"
              "etiqueta" => "19"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Failed heart rate control with oral metoprolol prior to coronary CT angiography&#58; effect of additional intravenous metoprolol on heart rate&#44; image quality and radiation dose"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "L&#46; Jim&#233;nez-Juan"
                            1 => "E&#46;T&#46; Nguyen"
                            2 => "B&#46;J&#46; Wintersperger"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1007/s10554-012-0049-x"
                      "Revista" => array:6 [
                        "tituloSerie" => "Int J Cardiovasc Imaging"
                        "fecha" => "2013"
                        "volumen" => "29"
                        "paginaInicial" => "199"
                        "paginaFinal" => "206"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22527260"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            19 => array:3 [
              "identificador" => "bib0210"
              "etiqueta" => "20"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Effective radiation dose of three diagnostic tests in cardiology&#58; single photon emission computed tomography&#44; invasive coronary angiography and cardiac computed tomography angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "P&#46; de Ara&#250;jo Gon&#231;alves"
                            1 => "P&#46; Jer&#243;nimo Sousa"
                            2 => "R&#46; Cal&#233;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.repc.2013.05.005"
                      "Revista" => array:6 [
                        "tituloSerie" => "Rev Port Cardiol"
                        "fecha" => "2013"
                        "volumen" => "32"
                        "paginaInicial" => "981"
                        "paginaFinal" => "986"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24287017"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            20 => array:3 [
              "identificador" => "bib0215"
              "etiqueta" => "21"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Dual-source CT coronary angiography without heart rate or rhythm control in comparison with conventional coronary angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "X&#46;M&#46; Fang"
                            1 => "H&#46;W&#46; Chen"
                            2 => "X&#46;Y&#46; Hu"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1007/s10554-010-9686-0"
                      "Revista" => array:6 [
                        "tituloSerie" => "Int J Cardiovasc Imaging"
                        "fecha" => "2010"
                        "volumen" => "26"
                        "paginaInicial" => "323"
                        "paginaFinal" => "331"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20730495"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            21 => array:3 [
              "identificador" => "bib0220"
              "etiqueta" => "22"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "S&#46; Achenbach"
                            1 => "M&#46; Marwan"
                            2 => "D&#46; Ropers"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1093/eurheartj/ehp470"
                      "Revista" => array:6 [
                        "tituloSerie" => "Eur Heart J"
                        "fecha" => "2010"
                        "volumen" => "31"
                        "paginaInicial" => "340"
                        "paginaFinal" => "346"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/19897497"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
          ]
        ]
      ]
    ]
  ]
  "idiomaDefecto" => "en"
  "url" => "/21742049/0000003500000012/v2_201702040044/S2174204916302008/v2_201702040044/en/main.assets"
  "Apartado" => array:4 [
    "identificador" => "9917"
    "tipo" => "SECCION"
    "en" => array:2 [
      "titulo" => "Original Articles"
      "idiomaDefecto" => true
    ]
    "idiomaDefecto" => "en"
  ]
  "PDF" => "https://static.elsevier.es/multimedia/21742049/0000003500000012/v2_201702040044/S2174204916302008/v2_201702040044/en/main.pdf?idApp=UINPBA00004E&text.app=https://revportcardiol.org/"
  "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204916302008?idApp=UINPBA00004E"
]
Share
Journal Information

Statistics

Follow this link to access the full text of the article

Original Article
Bailout intravenous esmolol for heart rate control in cardiac computed tomography angiography
Esmolol endovenoso em regime bail out para controlo de frequência cardíaca na tomografia computorizada cardíaca
Sílvia Aguiar Rosaa,
Corresponding author
silviaguiarosa@gmail.com

Corresponding author.
, Ruben Ramosa, Hugo Marquesb, Rosana Santosb, Cecília Lealb, Helena Casadob, Márcia Saraivab, Luísa Figueiredob, Rui Cruz Ferreiraa
a Cardiology Department, Santa Marta Hospital, Lisbon, Portugal
b Radiology Department, Santa Marta Hospital, Lisbon, Portugal
Read
5927
Times
was read the article
1922
Total PDF
4005
Total HTML
Share statistics
 array:26 [
  "pii" => "S2174204916302008"
  "issn" => "21742049"
  "doi" => "10.1016/j.repce.2016.07.005"
  "estado" => "S300"
  "fechaPublicacion" => "2016-12-01"
  "aid" => "896"
  "copyright" => "Sociedade Portuguesa de Cardiologia"
  "copyrightAnyo" => "2016"
  "documento" => "article"
  "crossmark" => 1
  "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
  "subdocumento" => "fla"
  "cita" => "Rev Port Cardiol. 2016;35:673-8"
  "abierto" => array:3 [
    "ES" => true
    "ES2" => true
    "LATM" => true
  ]
  "gratuito" => true
  "lecturas" => array:2 [
    "total" => 2478
    "formatos" => array:3 [
      "EPUB" => 149
      "HTML" => 1979
      "PDF" => 350
    ]
  ]
  "Traduccion" => array:1 [
    "en" => array:20 [
      "pii" => "S0870255116302268"
      "issn" => "08702551"
      "doi" => "10.1016/j.repc.2016.07.004"
      "estado" => "S300"
      "fechaPublicacion" => "2016-12-01"
      "aid" => "896"
      "copyright" => "Sociedade Portuguesa de Cardiologia"
      "documento" => "article"
      "crossmark" => 1
      "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
      "subdocumento" => "fla"
      "cita" => "Rev Port Cardiol. 2016;35:673-8"
      "abierto" => array:3 [
        "ES" => true
        "ES2" => true
        "LATM" => true
      ]
      "gratuito" => true
      "lecturas" => array:2 [
        "total" => 2556
        "formatos" => array:3 [
          "EPUB" => 177
          "HTML" => 1905
          "PDF" => 474
        ]
      ]
      "en" => array:13 [
        "idiomaDefecto" => true
        "cabecera" => "<span class="elsevierStyleTextfn">Original Article</span>"
        "titulo" => "Bailout intravenous esmolol for heart rate control in cardiac computed tomography angiography"
        "tienePdf" => "en"
        "tieneTextoCompleto" => "en"
        "tieneResumen" => array:2 [
          0 => "en"
          1 => "pt"
        ]
        "paginas" => array:1 [
          0 => array:2 [
            "paginaInicial" => "673"
            "paginaFinal" => "678"
          ]
        ]
        "titulosAlternativos" => array:1 [
          "pt" => array:1 [
            "titulo" => "Esmolol endovenoso em regime <span class="elsevierStyleItalic">bail out</span> para controlo de frequ&#234;ncia card&#237;aca na tomografia computorizada card&#237;aca"
          ]
        ]
        "contieneResumen" => array:2 [
          "en" => true
          "pt" => true
        ]
        "contieneTextoCompleto" => array:1 [
          "en" => true
        ]
        "contienePdf" => array:1 [
          "en" => true
        ]
        "resumenGrafico" => array:2 [
          "original" => 0
          "multimedia" => array:7 [
            "identificador" => "fig0015"
            "etiqueta" => "Figure 3"
            "tipo" => "MULTIMEDIAFIGURA"
            "mostrarFloat" => true
            "mostrarDisplay" => false
            "figura" => array:1 [
              0 => array:4 [
                "imagen" => "gr3.jpeg"
                "Alto" => 647
                "Ancho" => 1580
                "Tamanyo" => 44471
              ]
            ]
            "descripcion" => array:1 [
              "en" => "<p id="spar0055" class="elsevierStyleSimplePara elsevierViewall">Improvement in primary efficacy endpoint &#40;heart rate &#60;65 bpm&#41; when intravenous esmolol was added to the heart rate reduction protocol&#46; CCTA&#58; cardiac computed tomography angiography&#59; HR&#58; heart rate&#46;</p>"
            ]
          ]
        ]
        "autores" => array:1 [
          0 => array:2 [
            "autoresLista" => "S&#237;lvia Aguiar Rosa, Ruben Ramos, Hugo Marques, Rosana Santos, Cec&#237;lia Leal, Helena Casado, M&#225;rcia Saraiva, Lu&#237;sa Figueiredo, Rui Cruz Ferreira"
            "autores" => array:9 [
              0 => array:2 [
                "nombre" => "S&#237;lvia"
                "apellidos" => "Aguiar Rosa"
              ]
              1 => array:2 [
                "nombre" => "Ruben"
                "apellidos" => "Ramos"
              ]
              2 => array:2 [
                "nombre" => "Hugo"
                "apellidos" => "Marques"
              ]
              3 => array:2 [
                "nombre" => "Rosana"
                "apellidos" => "Santos"
              ]
              4 => array:2 [
                "nombre" => "Cec&#237;lia"
                "apellidos" => "Leal"
              ]
              5 => array:2 [
                "nombre" => "Helena"
                "apellidos" => "Casado"
              ]
              6 => array:2 [
                "nombre" => "M&#225;rcia"
                "apellidos" => "Saraiva"
              ]
              7 => array:2 [
                "nombre" => "Lu&#237;sa"
                "apellidos" => "Figueiredo"
              ]
              8 => array:2 [
                "nombre" => "Rui"
                "apellidos" => "Cruz Ferreira"
              ]
            ]
          ]
        ]
      ]
      "idiomaDefecto" => "en"
      "Traduccion" => array:1 [
        "en" => array:9 [
          "pii" => "S2174204916302008"
          "doi" => "10.1016/j.repce.2016.07.005"
          "estado" => "S300"
          "subdocumento" => ""
          "abierto" => array:3 [
            "ES" => true
            "ES2" => true
            "LATM" => true
          ]
          "gratuito" => true
          "lecturas" => array:1 [
            "total" => 0
          ]
          "idiomaDefecto" => "en"
          "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204916302008?idApp=UINPBA00004E"
        ]
      ]
      "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0870255116302268?idApp=UINPBA00004E"
      "url" => "/08702551/0000003500000012/v2_201701270020/S0870255116302268/v2_201701270020/en/main.assets"
    ]
  ]
  "itemSiguiente" => array:20 [
    "pii" => "S2174204916301957"
    "issn" => "21742049"
    "doi" => "10.1016/j.repce.2016.10.001"
    "estado" => "S300"
    "fechaPublicacion" => "2016-12-01"
    "aid" => "900"
    "copyright" => "Sociedade Portuguesa de Cardiologia"
    "documento" => "simple-article"
    "crossmark" => 1
    "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
    "subdocumento" => "dis"
    "cita" => "Rev Port Cardiol. 2016;35:679-80"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 2711
      "formatos" => array:3 [
        "EPUB" => 157
        "HTML" => 2042
        "PDF" => 512
      ]
    ]
    "en" => array:10 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Editorial comment</span>"
      "titulo" => "Heart rate reduction for cardiac computed tomography&#58; A necessary evil&#63;"
      "tienePdf" => "en"
      "tieneTextoCompleto" => "en"
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "679"
          "paginaFinal" => "680"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "es" => array:1 [
          "titulo" => "Redu&#231;&#227;o da frequ&#234;ncia card&#237;aca para a tomografia computorizada card&#237;aca&#58; um mal necess&#225;rio&#63;"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "en" => true
      ]
      "contienePdf" => array:1 [
        "en" => true
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "Pedro de Ara&#250;jo Gon&#231;alves"
          "autores" => array:1 [
            0 => array:2 [
              "nombre" => "Pedro"
              "apellidos" => "de Ara&#250;jo Gon&#231;alves"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "en"
    "Traduccion" => array:1 [
      "pt" => array:9 [
        "pii" => "S0870255116302347"
        "doi" => "10.1016/j.repc.2016.10.001"
        "estado" => "S300"
        "subdocumento" => ""
        "abierto" => array:3 [
          "ES" => true
          "ES2" => true
          "LATM" => true
        ]
        "gratuito" => true
        "lecturas" => array:1 [
          "total" => 0
        ]
        "idiomaDefecto" => "pt"
        "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0870255116302347?idApp=UINPBA00004E"
      ]
    ]
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204916301957?idApp=UINPBA00004E"
    "url" => "/21742049/0000003500000012/v2_201702040044/S2174204916301957/v2_201702040044/en/main.assets"
  ]
  "itemAnterior" => array:19 [
    "pii" => "S2174204916302021"
    "issn" => "21742049"
    "doi" => "10.1016/j.repce.2016.10.004"
    "estado" => "S300"
    "fechaPublicacion" => "2016-12-01"
    "aid" => "912"
    "documento" => "simple-article"
    "crossmark" => 1
    "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
    "subdocumento" => "dis"
    "cita" => "Rev Port Cardiol. 2016;35:669-71"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 2137
      "formatos" => array:3 [
        "EPUB" => 154
        "HTML" => 1509
        "PDF" => 474
      ]
    ]
    "en" => array:10 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Editorial comment</span>"
      "titulo" => "Cardiac rehabilitation in Portugal&#58; The situation in 2013-2014"
      "tienePdf" => "en"
      "tieneTextoCompleto" => "en"
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "669"
          "paginaFinal" => "671"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "pt" => array:1 [
          "titulo" => "Reabilita&#231;&#227;o card&#237;aca em Portugal&#46; Ponto da situa&#231;&#227;o em 2013-2014"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "en" => true
      ]
      "contienePdf" => array:1 [
        "en" => true
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "Miguel Mendes"
          "autores" => array:1 [
            0 => array:2 [
              "nombre" => "Miguel"
              "apellidos" => "Mendes"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "en"
    "Traduccion" => array:1 [
      "pt" => array:9 [
        "pii" => "S087025511630302X"
        "doi" => "10.1016/j.repc.2016.10.004"
        "estado" => "S300"
        "subdocumento" => ""
        "abierto" => array:3 [
          "ES" => true
          "ES2" => true
          "LATM" => true
        ]
        "gratuito" => true
        "lecturas" => array:1 [
          "total" => 0
        ]
        "idiomaDefecto" => "pt"
        "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S087025511630302X?idApp=UINPBA00004E"
      ]
    ]
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204916302021?idApp=UINPBA00004E"
    "url" => "/21742049/0000003500000012/v2_201702040044/S2174204916302021/v2_201702040044/en/main.assets"
  ]
  "asociados" => array:1 [
    0 => array:20 [
      "pii" => "S2174204916301957"
      "issn" => "21742049"
      "doi" => "10.1016/j.repce.2016.10.001"
      "estado" => "S300"
      "fechaPublicacion" => "2016-12-01"
      "aid" => "900"
      "copyright" => "Sociedade Portuguesa de Cardiologia"
      "documento" => "simple-article"
      "crossmark" => 1
      "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
      "subdocumento" => "dis"
      "cita" => "Rev Port Cardiol. 2016;35:679-80"
      "abierto" => array:3 [
        "ES" => true
        "ES2" => true
        "LATM" => true
      ]
      "gratuito" => true
      "lecturas" => array:2 [
        "total" => 2711
        "formatos" => array:3 [
          "EPUB" => 157
          "HTML" => 2042
          "PDF" => 512
        ]
      ]
      "en" => array:10 [
        "idiomaDefecto" => true
        "cabecera" => "<span class="elsevierStyleTextfn">Editorial comment</span>"
        "titulo" => "Heart rate reduction for cardiac computed tomography&#58; A necessary evil&#63;"
        "tienePdf" => "en"
        "tieneTextoCompleto" => "en"
        "paginas" => array:1 [
          0 => array:2 [
            "paginaInicial" => "679"
            "paginaFinal" => "680"
          ]
        ]
        "titulosAlternativos" => array:1 [
          "es" => array:1 [
            "titulo" => "Redu&#231;&#227;o da frequ&#234;ncia card&#237;aca para a tomografia computorizada card&#237;aca&#58; um mal necess&#225;rio&#63;"
          ]
        ]
        "contieneTextoCompleto" => array:1 [
          "en" => true
        ]
        "contienePdf" => array:1 [
          "en" => true
        ]
        "autores" => array:1 [
          0 => array:2 [
            "autoresLista" => "Pedro de Ara&#250;jo Gon&#231;alves"
            "autores" => array:1 [
              0 => array:2 [
                "nombre" => "Pedro"
                "apellidos" => "de Ara&#250;jo Gon&#231;alves"
              ]
            ]
          ]
        ]
      ]
      "idiomaDefecto" => "en"
      "Traduccion" => array:1 [
        "pt" => array:9 [
          "pii" => "S0870255116302347"
          "doi" => "10.1016/j.repc.2016.10.001"
          "estado" => "S300"
          "subdocumento" => ""
          "abierto" => array:3 [
            "ES" => true
            "ES2" => true
            "LATM" => true
          ]
          "gratuito" => true
          "lecturas" => array:1 [
            "total" => 0
          ]
          "idiomaDefecto" => "pt"
          "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0870255116302347?idApp=UINPBA00004E"
        ]
      ]
      "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204916301957?idApp=UINPBA00004E"
      "url" => "/21742049/0000003500000012/v2_201702040044/S2174204916301957/v2_201702040044/en/main.assets"
    ]
  ]
  "en" => array:19 [
    "idiomaDefecto" => true
    "cabecera" => "<span class="elsevierStyleTextfn">Original Article</span>"
    "titulo" => "Bailout intravenous esmolol for heart rate control in cardiac computed tomography angiography"
    "tieneTextoCompleto" => true
    "paginas" => array:1 [
      0 => array:2 [
        "paginaInicial" => "673"
        "paginaFinal" => "678"
      ]
    ]
    "autores" => array:1 [
      0 => array:4 [
        "autoresLista" => "S&#237;lvia Aguiar Rosa, Ruben Ramos, Hugo Marques, Rosana Santos, Cec&#237;lia Leal, Helena Casado, M&#225;rcia Saraiva, Lu&#237;sa Figueiredo, Rui Cruz Ferreira"
        "autores" => array:9 [
          0 => array:4 [
            "nombre" => "S&#237;lvia"
            "apellidos" => "Aguiar Rosa"
            "email" => array:1 [
              0 => "silviaguiarosa&#64;gmail&#46;com"
            ]
            "referencia" => array:2 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "aff0005"
              ]
              1 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">&#42;</span>"
                "identificador" => "cor0005"
              ]
            ]
          ]
          1 => array:3 [
            "nombre" => "Ruben"
            "apellidos" => "Ramos"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "aff0005"
              ]
            ]
          ]
          2 => array:3 [
            "nombre" => "Hugo"
            "apellidos" => "Marques"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">b</span>"
                "identificador" => "aff0010"
              ]
            ]
          ]
          3 => array:3 [
            "nombre" => "Rosana"
            "apellidos" => "Santos"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">b</span>"
                "identificador" => "aff0010"
              ]
            ]
          ]
          4 => array:3 [
            "nombre" => "Cec&#237;lia"
            "apellidos" => "Leal"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">b</span>"
                "identificador" => "aff0010"
              ]
            ]
          ]
          5 => array:3 [
            "nombre" => "Helena"
            "apellidos" => "Casado"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">b</span>"
                "identificador" => "aff0010"
              ]
            ]
          ]
          6 => array:3 [
            "nombre" => "M&#225;rcia"
            "apellidos" => "Saraiva"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">b</span>"
                "identificador" => "aff0010"
              ]
            ]
          ]
          7 => array:3 [
            "nombre" => "Lu&#237;sa"
            "apellidos" => "Figueiredo"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">b</span>"
                "identificador" => "aff0010"
              ]
            ]
          ]
          8 => array:3 [
            "nombre" => "Rui"
            "apellidos" => "Cruz Ferreira"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "aff0005"
              ]
            ]
          ]
        ]
        "afiliaciones" => array:2 [
          0 => array:3 [
            "entidad" => "Cardiology Department&#44; Santa Marta Hospital&#44; Lisbon&#44; Portugal"
            "etiqueta" => "a"
            "identificador" => "aff0005"
          ]
          1 => array:3 [
            "entidad" => "Radiology Department&#44; Santa Marta Hospital&#44; Lisbon&#44; Portugal"
            "etiqueta" => "b"
            "identificador" => "aff0010"
          ]
        ]
        "correspondencia" => array:1 [
          0 => array:3 [
            "identificador" => "cor0005"
            "etiqueta" => "&#8270;"
            "correspondencia" => "Corresponding author&#46;"
          ]
        ]
      ]
    ]
    "titulosAlternativos" => array:1 [
      "pt" => array:1 [
        "titulo" => "Esmolol endovenoso em regime <span class="elsevierStyleItalic">bail out</span> para controlo de frequ&#234;ncia card&#237;aca na tomografia computorizada card&#237;aca"
      ]
    ]
    "resumenGrafico" => array:2 [
      "original" => 0
      "multimedia" => array:7 [
        "identificador" => "fig0005"
        "etiqueta" => "Figure 1"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr1.jpeg"
            "Alto" => 1424
            "Ancho" => 1374
            "Tamanyo" => 109598
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0045" class="elsevierStyleSimplePara elsevierViewall">Protocol flowchart&#46; CCTA&#58; cardiac computed tomography angiography&#59; CT&#58; computed tomography&#59; HR&#58; heart rate&#59; IV&#58; intravenous&#46;</p>"
        ]
      ]
    ]
    "textoCompleto" => "<span class="elsevierStyleSections"><span id="sec0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0065">Introduction</span><p id="par0005" class="elsevierStylePara elsevierViewall">Adequate heart rate &#40;HR&#41; control is paramount for optimal cardiac imaging using single-source 64-slice multidetector computed tomography &#40;64-MSDT&#41;&#46;<a class="elsevierStyleCrossRefs" href="#bib0115"><span class="elsevierStyleSup">1&#8211;5</span></a> For these scanners&#44; HR during image acquisition should be below 65 beats per minute &#40;bpm&#41; and preferably lower than 60 bpm for optimal image quality&#46;<a class="elsevierStyleCrossRef" href="#bib0140"><span class="elsevierStyleSup">6</span></a> However&#44; commonly used pre-medication regimens with oral or intravenous metoprolol are frequently unsatisfactory&#46;<a class="elsevierStyleCrossRefs" href="#bib0145"><span class="elsevierStyleSup">7&#8211;9</span></a> Side effects&#44; including hypotension and bradycardia&#44; are also points of concern&#46;</p><p id="par0010" class="elsevierStylePara elsevierViewall">Intravenous esmolol&#44; due to its rapid onset and short half-life&#44; has been reported as a valuable option for adequate HR control&#44; either alone or in combination with oral beta-blockers&#46;<a class="elsevierStyleCrossRefs" href="#bib0160"><span class="elsevierStyleSup">10&#8211;12</span></a></p><p id="par0015" class="elsevierStylePara elsevierViewall">The aim of the present study is to evaluate the efficacy and safety of an HR reduction protocol using intravenous esmolol as bailout for failed oral metoprolol regimens in patients undergoing coronary computed tomography &#40;CT&#41; angiography &#40;CCTA&#41;&#46;</p></span><span id="sec0010" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0070">Methods</span><span id="sec0015" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0075">Study population</span><p id="par0020" class="elsevierStylePara elsevierViewall">Patients undergoing CCTA in a tertiary academic medical center between August 2011 and June 2014 were analyzed&#46; Those presenting in sinus rhythm and without contraindications for beta-blockers were included&#46; All patients had indication for coronary anatomy assessment&#46; Nineteen patients also had associated secondary indications&#58; percutaneous aortic valve implantation &#40;two&#41;&#44; paroxysmal atrial fibrillation ablation &#40;sinus rhythm during CCTA&#41; &#40;three&#41;&#44; assessment of left ventricular morphology &#40;two&#41;&#44; evaluation of valve heart disease &#40;three&#41; or ascending aorta &#40;two&#41;&#44; and morphological studies for congenital heart disease &#40;seven&#41;&#46;</p></span><span id="sec0020" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0080">Patient preparation</span><p id="par0025" class="elsevierStylePara elsevierViewall">Oral metoprolol was not used for patients presenting with HR &#60;60 bpm&#44; who proceeded directly to the CT table&#46; Individuals with baseline HR of 60-65 bpm or &#62;65 bpm received 50 mg or 100 mg oral metoprolol&#44; respectively&#46; An additional dose of 100 mg metoprolol was administered one hour later if HR was still above 65 bpm&#46; After repeated oral metoprolol administration another 60 min interval was allowed&#46; Patients were then moved to the CT table&#46; After sublingual nitrate administration and just after scouting or calcium score image acquisition &#40;<a class="elsevierStyleCrossRef" href="#fig0005">Figure 1</a>&#41;&#44; an intravenous &#40;IV&#41; bolus of esmolol 1 or 2 mg&#47;kg was administered if HR was &#62;65 bpm or &#62;70 bpm&#44; respectively&#46; A second bolus of esmolol was administered 1 min later if HR remained above 65 bpm using the same dosage&#46;</p><elsevierMultimedia ident="fig0005"></elsevierMultimedia><p id="par0030" class="elsevierStylePara elsevierViewall">Blood pressure and HR were assessed at baseline&#44; in the CT room before and after scanning&#44; and before discharge until systolic blood pressure &#40;SBP&#41; was &#62;100 mmHg and HR &#62;50 bpm or had returned to baseline&#46;</p></span><span id="sec0025" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0085">Scan protocol and image reconstruction</span><p id="par0035" class="elsevierStylePara elsevierViewall">A single scanner was used for all cases &#40;LightSpeed VCT XT&#44; GE Healthcare&#44; Milwaukee&#44; USA&#41;&#46; First&#44; unenhanced prospective heart rate-triggered axial scanning of the heart was performed for calcium scoring &#40;slice thickness 2&#46;5 mm&#59; voltage 120 kV&#44; tube current 70 mA&#59; 0&#46;35 s partial rotation&#41; just after sublingual nitrate administration&#46; In view of the requirement for esmolol administration &#40;HR on the CT table &#62;65 bpm&#41; a conservative acquisition approach was used and retrospective gating with dose modulation was selected for all these patients&#46; The contrast-enhanced scan was obtained using Visipaque&#8482; &#40;iodixanol&#41; 320 mg injected through a peripheral vein at 5 ml&#47;s followed by a saline bolus chase&#46; The scan parameters used were 0&#46;625 mm collimation&#44; rotation time 350 ms&#44; pitch adjusted to each patient&#39;s HR&#44; tube voltage 80-120 mV&#44; and effective mA 100-600&#46;</p><p id="par0040" class="elsevierStylePara elsevierViewall">Estimated effective radiation dose was calculated by applying a factor of 0&#46;014 to the volumetric CT dose&#46; Calcium scoring was included in the total effective radiation dose&#46; Electrocardiographically gated datasets were reconstructed from 40&#37; to 80&#37; of the R-R cycle length in 10&#37; increments&#46;</p></span><span id="sec0030" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0090">Endpoints</span><p id="par0045" class="elsevierStylePara elsevierViewall">The primary efficacy endpoint was HR &#60;65 bpm during contrast image acquisition and the secondary efficacy endpoint was HR &#60;60 bpm during contrast image acquisition&#46;</p><p id="par0050" class="elsevierStylePara elsevierViewall">The primary safety endpoint was symptomatic hypotension &#40;SBP &#60;90 mmHg&#41; or bradycardia &#40;heart rate &#60;45 bpm&#41; up to hospital discharge&#44; while the secondary safety endpoints were SBP &#60;90 mmHg or HR &#60;45 bpm &#40;with or without symptoms&#41; up to hospital discharge&#46;</p></span><span id="sec0035" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0095">Statistical analysis</span><p id="par0055" class="elsevierStylePara elsevierViewall">The statistical analysis was performed using IBM SPSS Statistics &#40;version 22&#59; IBM SPSS&#44; Chicago&#44; IL&#41;&#46; Continuous variables were expressed as mean &#177; standard deviation or median &#177; interquartile range&#46; Normality was tested by the Kolmogorov-Smirnov test&#46; Study group characteristics were compared using the Student&#39;s t test or the Wilcoxon-Mann-Whitney test for continuous variables&#44; and Pearson&#39;s chi-square test or Fisher&#39;s exact test for categorical measures&#44; as appropriate&#46;</p></span></span><span id="sec0040" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0100">Results</span><p id="par0060" class="elsevierStylePara elsevierViewall">Of the 947 CCTAs performed &#40;76&#37; of all CCTAs performed in the study period&#41;&#44; HR &#60;65 bpm during CCTA acquisition was achieved in 830 cases &#40;86&#37;&#41; using the oral metoprolol regimen alone&#46; Intravenous esmolol was necessary in the other 130 patients &#40;54&#37; male&#44; mean age 60&#46;9&#177;13&#46;8 years and body mass index 27&#46;40&#177;4&#46;42 kg&#47;m<span class="elsevierStyleSup">2</span>&#41; &#40;<a class="elsevierStyleCrossRef" href="#tbl0005">Table 1</a>&#41;&#46; Nearly half &#40;53&#37;&#41; of the esmolol-treated patients had been pre-medicated before admission with oral beta-blockers in accordance with the indications of the referring physician&#46;</p><elsevierMultimedia ident="tbl0005"></elsevierMultimedia><p id="par0065" class="elsevierStylePara elsevierViewall">In about one third &#40;35&#37;&#41; of esmolol-treated patients&#44; HR on presentation was &#60;60 bpm and thus they received no oral metoprolol&#44; but on the CT table HR increased to &#62;65 bpm requiring IV esmolol as per protocol&#46; The remaining 65&#37; &#40;84 patients&#41; had received in-hospital oral metoprolol &#40;mean dose 0&#46;69 mg&#47;kg&#41; according to the predefined study protocol&#46; The mean time between first oral dose of metoprolol and intravenous esmolol administration was 82&#177;39 min&#46; The mean esmolol dose administered was 1&#46;54 mg&#47;kg&#46;</p><p id="par0070" class="elsevierStylePara elsevierViewall">Initial mean HR in esmolol-treated patients was 74&#177;14 bpm&#44; which decreased to 63&#177;9 bpm during CCTA acquisition &#40;p&#60;0&#46;001&#41;&#44; corresponding to a significant mean reduction in HR of 15&#177;13&#37; &#40;<a class="elsevierStyleCrossRef" href="#fig0010">Figure 2</a>&#41;&#46; During CCTA HR variability&#44; defined as &#40;maximum HR - minimum HR&#41;&#47;mean HR&#44; was 6&#46;3&#177;7&#46;1 in esmolol patients&#46;</p><elsevierMultimedia ident="fig0010"></elsevierMultimedia><p id="par0075" class="elsevierStylePara elsevierViewall">HR &#60;65 bpm was achieved in 82 of the 130 esmolol-treated patients &#40;63&#37;&#41;&#46; Thus&#44; considering the entire CCTA population&#44; the combined metoprolol&#47;esmolol regimen led to a significant increase in the primary efficacy endpoint&#44; from 86&#37; to 95&#37; &#40;p&#60;0&#46;001&#41; &#40;<a class="elsevierStyleCrossRef" href="#fig0015">Figure 3</a>&#41;&#46;</p><elsevierMultimedia ident="fig0015"></elsevierMultimedia><p id="par0080" class="elsevierStylePara elsevierViewall">The secondary efficacy endpoint &#40;HR &#60;60 bpm&#41; was reached in 47 of the 130 esmolol patients &#40;36&#37;&#41;&#46;</p><p id="par0085" class="elsevierStylePara elsevierViewall">Four of the esmolol-treated patients &#40;3&#37;&#41; had minimum HR below 45 bpm&#46; Mean time to HR recovery to &#62;60 bpm in these patients was 37&#46;8&#177;32&#46;3 min&#46; During CCTA&#44; HR above 80 bpm was observed in five &#40;4&#37;&#41; patients&#46; Mean HR at discharge was 64&#177;7 bpm &#40;<a class="elsevierStyleCrossRef" href="#fig0010">Figure 2</a>&#41; in the esmolol group&#46;</p><p id="par0090" class="elsevierStylePara elsevierViewall">Esmolol use resulted in a significant reduction in mean SBP &#40;143&#177;21 to 115&#177;17 mmHg&#59; p&#60;0&#46;001&#41;&#46; In 11 patients &#40;8&#37;&#41; SBP decreased to levels below 90 mmHg&#46; Mean SBP at discharge was 119&#177;18 mmHg &#40;<a class="elsevierStyleCrossRef" href="#fig0020">Figure 4</a>A&#41;&#46; Initial diastolic blood pressure was 80&#177;12 mmHg&#44; decreasing to 62&#177;11 mmHg after intravenous esmolol &#40;p&#60;0&#46;001&#41;&#46; Diastolic blood pressure at discharge was 69&#177;10 mmHg &#40;<a class="elsevierStyleCrossRef" href="#fig0020">Figure 4</a>B&#41;&#46;</p><elsevierMultimedia ident="fig0020"></elsevierMultimedia><p id="par0095" class="elsevierStylePara elsevierViewall">The combined primary safety endpoint &#40;symptomatic hypotension or symptomatic bradycardia&#41; was only observed in two patients &#40;1&#46;5&#37;&#41;&#46; Both cases resolved with supine positioning&#44; intravenous fluids and atropine &#40;1 mg&#41; administration&#44; without further complications&#46;</p><p id="par0100" class="elsevierStylePara elsevierViewall">In esmolol-treated patients 113 scans &#40;87&#37;&#41; were of good image quality&#44; 10 &#40;8&#37;&#41; were of moderate quality&#44; and seven &#40;5&#37;&#41; were of poor quality and considered non-diagnostic&#46; In the latter group HR during CCTA was 75&#177;9 bpm and HR variability was 5&#46;3 &#40;42&#46;6&#41;&#46;</p><p id="par0105" class="elsevierStylePara elsevierViewall">Retrospective gating with dose modulation was selected for all esmolol-treated patient due to high baseline HR&#46; Mean estimated radiation dose was 9&#46;8&#177;10&#46;6 mSv&#46;</p></span><span id="sec0045" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0105">Discussion</span><p id="par0110" class="elsevierStylePara elsevierViewall">HR while scanning should be less than 65 bpm and ideally less than 60 bpm for optimal image quality when a 64-slice MDCT scanner is to be used&#46;<a class="elsevierStyleCrossRef" href="#bib0140"><span class="elsevierStyleSup">6</span></a> Despite this recommendation&#44; in 2007 an American survey showed that there were differences in beta-blocker protocols and that a cutoff higher than 65 bpm was used by 80&#37; of centers&#46;<a class="elsevierStyleCrossRef" href="#bib0175"><span class="elsevierStyleSup">13</span></a></p><p id="par0115" class="elsevierStylePara elsevierViewall">Metoprolol is the most common beta-blocker agent used to achieve HR control during CCTA&#46; However&#44; due to its low oral bioavailability&#44; variable metabolism and inter-subject variability&#44; the results are often suboptimal&#46; This has led to the use of several alternate regimens including intravenous metoprolol&#44; other beta-blockers such as atenolol&#44; ivabradine&#44; or calcium channel blockers&#46;<a class="elsevierStyleCrossRefs" href="#bib0180"><span class="elsevierStyleSup">14&#44;15</span></a> Nevertheless intravenous metoprolol&#44; the most commonly used parenteral beta-blocker&#44; has demonstrated limited efficacy in lowering HR&#46;</p><p id="par0120" class="elsevierStylePara elsevierViewall">Ivabradine has been suggested as an alternative to beta-blockers&#46; Regimens of oral ivabradine proved more effective in reducing HR than oral metoprolol<a class="elsevierStyleCrossRef" href="#bib0190"><span class="elsevierStyleSup">16</span></a> and an intravenous protocol demonstrated efficacy and safety in patients ineligible for intravenous beta-blockers&#46;<a class="elsevierStyleCrossRef" href="#bib0195"><span class="elsevierStyleSup">17</span></a></p><p id="par0125" class="elsevierStylePara elsevierViewall">Esmolol may be at least as efficacious as intravenous metoprolol to achieve optimal HR&#46;<a class="elsevierStyleCrossRef" href="#bib0170"><span class="elsevierStyleSup">12</span></a> However&#44; to our knowledge there are no studies reporting on esmolol use as bailout when previous oral HR regimens have failed&#46;</p><p id="par0130" class="elsevierStylePara elsevierViewall">In our study the oral metoprolol regimen used enabled 86&#37; of patients to achieve target HR &#60;65 bpm&#46; This percentage is higher than described in previous studies&#46; De Graaf et al&#46; demonstrated optimal beta-blockade in 73&#37; of CCTA patients using oral metoprolol&#46;<a class="elsevierStyleCrossRef" href="#bib0200"><span class="elsevierStyleSup">18</span></a> Intravenous metoprolol&#44; also commonly used&#44; again demonstrated limited efficacy in lowering HR&#46; In a study by Jimenez-Juan et al&#46; only 42&#37; of patients who did not achieve HR &#60;60 bpm with oral metoprolol reached target HR with additional intravenous metoprolol&#46;<a class="elsevierStyleCrossRef" href="#bib0205"><span class="elsevierStyleSup">19</span></a> These findings highlight the need for a more effective protocol for HR control&#46; In addition&#44; the rapid action and short half-life of esmolol make it an attractive drug in this setting&#46; Similarly to data reported by Degertekin et al&#46;&#44;<a class="elsevierStyleCrossRef" href="#bib0160"><span class="elsevierStyleSup">10</span></a> in our study bolus esmolol produced HR below 65 bpm in 63&#37; &#40;82&#47;130&#41; of patients&#46; Thus&#44; the introduction of bailout intravenous esmolol enabled 95&#37; of the entire cohort to be imaged with HR below 65 bpm&#46; The mean HR reduction was 11 bpm&#44; 4&#37; of patients were imaged with HR greater than 80 bpm and only 5&#37; of CCTA exams were considered to be non-diagnostic&#46;</p><p id="par0135" class="elsevierStylePara elsevierViewall">Our study suggests that despite an aggressive beta-blocker strategy&#44; the risk of side effects was relatively small&#46; Only 1&#46;5&#37; of patients had symptomatic hypotension or bradycardia&#46; Wang et al&#46; reported 0&#46;4&#37; incidence of adverse events in a Chinese population treated with intravenous esmolol only&#46;<a class="elsevierStyleCrossRef" href="#bib0165"><span class="elsevierStyleSup">11</span></a> In our cohort&#44; however&#44; esmolol was used on top of oral metoprolol in 64&#37; of cases&#44; which could explain the higher incidence of side effects&#46; Contraindications for beta-blockers are often considered a limitation for CCTA in patients with relatively high HR&#46; Esmolol&#39;s short half-life could make it useful for patients who cannot tolerate prolonged beta-blockade&#46;</p><p id="par0140" class="elsevierStylePara elsevierViewall">We reported a higher effective radiation dose than some real-world registries&#46;<a class="elsevierStyleCrossRef" href="#bib0210"><span class="elsevierStyleSup">20</span></a> Unlike these studies&#44; in which both prospective and retrospective acquisition protocols are reported&#44; herein we report on a specific population subset in which only a retrospective acquisition protocol was chosen for all patients &#40;because of high baseline HR&#41;&#46; Also&#44; in our registry about 15&#37; of esmolol-treated patients had secondary indications for scanning&#44; such as study for transcatheter aortic valve implantation&#44; in which the scan range is significantly greater&#46;</p><p id="par0145" class="elsevierStylePara elsevierViewall">The introduction of high temporal resolution &#40;83 ms&#41; dual-source CT in clinical practice in 2005 has enabled high image quality diagnostic CCTA studies at increased HR with less dependency on HR lowering agents&#46;<a class="elsevierStyleCrossRef" href="#bib0215"><span class="elsevierStyleSup">21</span></a> However&#44; the latest generation of dual-source scanners has introduced a new scan mode&#44; prospectively ECG-triggered helical data acquisition with very high pitch values&#46; The high pitch enables acquisition with very low radiation exposure &#40;&#60;1 mSv&#41; but low and regular HR is critical for this technique&#46; Consequently&#44; effective HR reduction strategies are yet again pivotal if such very low dose acquisition protocols are to be followed&#46;<a class="elsevierStyleCrossRef" href="#bib0220"><span class="elsevierStyleSup">22</span></a></p></span><span id="sec0050" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0110">Study limitations</span><p id="par0150" class="elsevierStylePara elsevierViewall">This is a retrospective study with inherent limitations including potential selection bias&#46; However&#44; the HR control protocol was prospectively designed and uniformly applied to all eligible patients&#46; Also&#44; this was a single-center experience with a relatively small sample of esmolol-treated patients&#46; Larger multicenter trials using placebo or intravenous metoprolol as active controls will be needed to clearly establish the role of intravenous esmolol in this setting&#46;</p></span><span id="sec0055" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0115">Conclusion</span><p id="par0155" class="elsevierStylePara elsevierViewall">Despite optimal use of oral metoprolol for HR control before CCTA&#44; 14&#37; of cases still required intravenous esmolol for HR control&#46; Bailout administration of intravenous esmolol on the CT table was safe and effective and enabled 95&#37; of patients to be imaged with HR below 65 bpm&#46;</p></span><span id="sec0060" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0120">Ethical disclosures</span><span id="sec0065" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0125">Protection of human and animal subjects</span><p id="par0160" class="elsevierStylePara elsevierViewall">The authors declare that no experiments were performed on humans or animals for this study&#46;</p></span><span id="sec0070" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0130">Confidentiality of data</span><p id="par0165" class="elsevierStylePara elsevierViewall">The authors declare that they have followed the protocols of their work center on the publication of patient data&#46;</p></span><span id="sec0075" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0135">Right to privacy and informed consent</span><p id="par0170" class="elsevierStylePara elsevierViewall">The authors have obtained the written informed consent of the patients or subjects mentioned in the article&#46; The corresponding author is in possession of this document&#46;</p></span></span><span id="sec0080" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0140">Conflicts of interest</span><p id="par0175" class="elsevierStylePara elsevierViewall">The authors have no conflicts of interest to declare&#46;</p></span></span>"
    "textoCompletoSecciones" => array:1 [
      "secciones" => array:13 [
        0 => array:3 [
          "identificador" => "xres798192"
          "titulo" => "Abstract"
          "secciones" => array:4 [
            0 => array:2 [
              "identificador" => "abst0005"
              "titulo" => "Objective"
            ]
            1 => array:2 [
              "identificador" => "abst0010"
              "titulo" => "Methods"
            ]
            2 => array:2 [
              "identificador" => "abst0015"
              "titulo" => "Results"
            ]
            3 => array:2 [
              "identificador" => "abst0020"
              "titulo" => "Conclusion"
            ]
          ]
        ]
        1 => array:2 [
          "identificador" => "xpalclavsec796161"
          "titulo" => "Keywords"
        ]
        2 => array:3 [
          "identificador" => "xres798191"
          "titulo" => "Resumo"
          "secciones" => array:4 [
            0 => array:2 [
              "identificador" => "abst0025"
              "titulo" => "Objetivo"
            ]
            1 => array:2 [
              "identificador" => "abst0030"
              "titulo" => "M&#233;todos"
            ]
            2 => array:2 [
              "identificador" => "abst0035"
              "titulo" => "Resultados"
            ]
            3 => array:2 [
              "identificador" => "abst0040"
              "titulo" => "Conclus&#227;o"
            ]
          ]
        ]
        3 => array:2 [
          "identificador" => "xpalclavsec796160"
          "titulo" => "Palavras-chave"
        ]
        4 => array:2 [
          "identificador" => "sec0005"
          "titulo" => "Introduction"
        ]
        5 => array:3 [
          "identificador" => "sec0010"
          "titulo" => "Methods"
          "secciones" => array:5 [
            0 => array:2 [
              "identificador" => "sec0015"
              "titulo" => "Study population"
            ]
            1 => array:2 [
              "identificador" => "sec0020"
              "titulo" => "Patient preparation"
            ]
            2 => array:2 [
              "identificador" => "sec0025"
              "titulo" => "Scan protocol and image reconstruction"
            ]
            3 => array:2 [
              "identificador" => "sec0030"
              "titulo" => "Endpoints"
            ]
            4 => array:2 [
              "identificador" => "sec0035"
              "titulo" => "Statistical analysis"
            ]
          ]
        ]
        6 => array:2 [
          "identificador" => "sec0040"
          "titulo" => "Results"
        ]
        7 => array:2 [
          "identificador" => "sec0045"
          "titulo" => "Discussion"
        ]
        8 => array:2 [
          "identificador" => "sec0050"
          "titulo" => "Study limitations"
        ]
        9 => array:2 [
          "identificador" => "sec0055"
          "titulo" => "Conclusion"
        ]
        10 => array:3 [
          "identificador" => "sec0060"
          "titulo" => "Ethical disclosures"
          "secciones" => array:3 [
            0 => array:2 [
              "identificador" => "sec0065"
              "titulo" => "Protection of human and animal subjects"
            ]
            1 => array:2 [
              "identificador" => "sec0070"
              "titulo" => "Confidentiality of data"
            ]
            2 => array:2 [
              "identificador" => "sec0075"
              "titulo" => "Right to privacy and informed consent"
            ]
          ]
        ]
        11 => array:2 [
          "identificador" => "sec0080"
          "titulo" => "Conflicts of interest"
        ]
        12 => array:1 [
          "titulo" => "References"
        ]
      ]
    ]
    "pdfFichero" => "main.pdf"
    "tienePdf" => true
    "fechaRecibido" => "2016-02-09"
    "fechaAceptado" => "2016-07-08"
    "PalabrasClave" => array:2 [
      "en" => array:1 [
        0 => array:4 [
          "clase" => "keyword"
          "titulo" => "Keywords"
          "identificador" => "xpalclavsec796161"
          "palabras" => array:3 [
            0 => "Coronary computed tomography angiography"
            1 => "Esmolol"
            2 => "Heart rate control"
          ]
        ]
      ]
      "pt" => array:1 [
        0 => array:4 [
          "clase" => "keyword"
          "titulo" => "Palavras-chave"
          "identificador" => "xpalclavsec796160"
          "palabras" => array:3 [
            0 => "Angiografia coron&#225;ria por tomografia computorizada"
            1 => "Esmolol"
            2 => "Controlo de frequ&#234;ncia card&#237;aca"
          ]
        ]
      ]
    ]
    "tieneResumen" => true
    "resumen" => array:2 [
      "en" => array:3 [
        "titulo" => "Abstract"
        "resumen" => "<span id="abst0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0010">Objective</span><p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">To evaluate the efficacy and safety of a heart rate &#40;HR&#41; reduction protocol using intravenous esmolol as bailout for failed oral metoprolol regimens in patients undergoing coronary computed tomography angiography &#40;CCTA&#41; with 64-slice multidetector computed tomography &#40;64-MDCT&#41;&#46;</p></span> <span id="abst0010" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0015">Methods</span><p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">Patients who underwent cardiac 64-MDCT in a single institution between 2011 and 2014 were analyzed&#46; Those with HR above 60 beats per minute &#40;bpm&#41; on presentation received oral metoprolol &#40;50-200 mg&#41; at least one hour before CCTA&#46; Intravenous esmolol 1-2 mg&#47;kg was administered as a bolus whenever HR remained over 65 bpm just before imaging&#46; The primary efficacy endpoint was HR &#60;65 bpm during CCTA&#46; The primary safety endpoint was symptomatic hypotension or bradycardia up to hospital discharge&#46;</p></span> <span id="abst0015" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0020">Results</span><p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">During the study period CCTA was performed in 947 cases&#46; In 86&#37; of these&#44; oral metoprolol was the only medication required to successfully reduce HR &#60;60 bpm&#46; Esmolol was used in the remaining 130 patients &#40;14&#37;&#41;&#46; For esmolol-treated patients mean baseline and acquisition HR were 74&#177;14 bpm and 63&#177;9 bpm&#44; respectively &#40;p&#60;0&#46;001&#41;&#46; The target HR of &#60;65 bpm was achieved in 82 of the 130 esmolol-treated patients &#40;63&#37;&#41;&#46; Considering the whole population&#44; esmolol use led to a significant increase in the primary efficacy endpoint from 86&#37; to 95&#37; &#40;p&#60;0&#46;001&#41;&#46; Esmolol also resulted in a statistically&#44; but not clinically&#44; significant reduction in systolic blood pressure &#40;144&#177;22 to 115&#177;17 mmHg&#59; p&#60;0&#46;001&#41;&#46; The combined primary safety endpoint was only observed in two &#40;1&#46;5&#37;&#41; patients&#46;</p></span> <span id="abst0020" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0025">Conclusion</span><p id="spar0020" class="elsevierStyleSimplePara elsevierViewall">Despite optimal use of oral beta-blockers&#44; 14&#37; of patients needed intravenous esmolol for HR control&#46; The pre-medication combination of oral metoprolol and on-demand administration of intravenous esmolol was safe and effective and enabled 95&#37; of patients to be imaged with HR below 65 bpm&#46;</p></span>"
        "secciones" => array:4 [
          0 => array:2 [
            "identificador" => "abst0005"
            "titulo" => "Objective"
          ]
          1 => array:2 [
            "identificador" => "abst0010"
            "titulo" => "Methods"
          ]
          2 => array:2 [
            "identificador" => "abst0015"
            "titulo" => "Results"
          ]
          3 => array:2 [
            "identificador" => "abst0020"
            "titulo" => "Conclusion"
          ]
        ]
      ]
      "pt" => array:3 [
        "titulo" => "Resumo"
        "resumen" => "<span id="abst0025" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0035">Objetivo</span><p id="spar0025" class="elsevierStyleSimplePara elsevierViewall">Avaliar a efic&#225;cia e seguran&#231;a de um protocolo de redu&#231;&#227;o de frequ&#234;ncia card&#237;aca &#40;FC&#41; utilizando esmolol endovenoso ap&#243;s fal&#234;ncia de metoprolol oral&#44; em doentes submetidos a angiografia coron&#225;ria por tomografia computorizada &#40;CCTA&#41; de 64 cortes&#46;</p></span> <span id="abst0030" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0040">M&#233;todos</span><p id="spar0030" class="elsevierStyleSimplePara elsevierViewall">De 2011 a 2014 foram avaliados os indiv&#237;duos submetidos a CCTA num &#250;nico centro&#46; Os indiv&#237;duos com FC &#62;60 bpm &#224; admiss&#227;o receberam 50-200 mg de metoprolol oral pelo menos uma hora antes da CCTA&#46; Esmolol endovenoso em b&#243;lus &#40;1-2 mg&#47;kg&#41; foi administrado se FC &#62;65 bpm imediatamente antes da aquisi&#231;&#227;o de imagem&#46; O <span class="elsevierStyleItalic">endpoint</span> prim&#225;rio de efic&#225;cia foi FC &#60;65 bpm durante a aquisi&#231;&#227;o de imagem com contraste&#46; O <span class="elsevierStyleItalic">endpoint</span> prim&#225;rio de seguran&#231;a foi hipotens&#227;o ou bradicardia sintom&#225;tica durante a perman&#234;ncia no hospital&#46;</p></span> <span id="abst0035" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0045">Resultados</span><p id="spar0035" class="elsevierStyleSimplePara elsevierViewall">Foram efetuadas 947 CCTA durante o per&#237;odo de estudo&#46; Em 86&#37; dos casos&#44; metoprolol oral foi o &#250;nico f&#225;rmaco utilizado&#46; Foi necess&#225;ria a administra&#231;&#227;o de esmolol em 130 &#40;14&#37;&#41; doentes&#46; Nos doentes que receberam esmolol&#44; a FC basal reduziu em m&#233;dia de 74&#177;14 bpm para 63&#177;9 bpm &#40;p&#60;0&#44;001&#41;&#46; O objetivo prim&#225;rio de FC &#60;65 bpm foi alcan&#231;ado em 82 desses 130 doentes &#40;63&#37;&#41;&#46; Considerando toda a popula&#231;&#227;o&#44; o recurso a esmolol permitiu um aumento significativo da propor&#231;&#227;o de CCTA realizados com FC &#60;65 bpm &#40;86&#37; para 95&#37; &#91;p&#60;0&#44;001&#93;&#41;&#46; A administra&#231;&#227;o de esmolol esteve associada a redu&#231;&#227;o estatisticamente&#44; mas n&#227;o clinicamente&#44; significativa da press&#227;o arterial sist&#243;lica &#40;144&#177;22 para 115&#177;17 mmHg&#59; p&#60;0&#44;001&#41;&#46; O <span class="elsevierStyleItalic">endpoint</span> combinado de seguran&#231;a foi observado em dois &#40;1&#44;5&#37;&#41; dos doentes&#46;</p></span> <span id="abst0040" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0050">Conclus&#227;o</span><p id="spar0040" class="elsevierStyleSimplePara elsevierViewall">Apesar da utiliza&#231;&#227;o sistem&#225;tica de betabloqueante oral&#44; 14&#37; dos casos necessitaram de esmolol endovenoso para controlo adequado de FC&#46; Pr&#233;-medica&#231;&#227;o combinada de metoprolol oral e esmolol endovenoso quando necess&#225;ria foi segura e eficaz&#44; e permitiu que 95&#37; dos doentes apresentassem FC &#60;65 bpm no momento da aquisi&#231;&#227;o de imagem&#46;</p></span>"
        "secciones" => array:4 [
          0 => array:2 [
            "identificador" => "abst0025"
            "titulo" => "Objetivo"
          ]
          1 => array:2 [
            "identificador" => "abst0030"
            "titulo" => "M&#233;todos"
          ]
          2 => array:2 [
            "identificador" => "abst0035"
            "titulo" => "Resultados"
          ]
          3 => array:2 [
            "identificador" => "abst0040"
            "titulo" => "Conclus&#227;o"
          ]
        ]
      ]
    ]
    "multimedia" => array:5 [
      0 => array:7 [
        "identificador" => "fig0005"
        "etiqueta" => "Figure 1"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr1.jpeg"
            "Alto" => 1424
            "Ancho" => 1374
            "Tamanyo" => 109598
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0045" class="elsevierStyleSimplePara elsevierViewall">Protocol flowchart&#46; CCTA&#58; cardiac computed tomography angiography&#59; CT&#58; computed tomography&#59; HR&#58; heart rate&#59; IV&#58; intravenous&#46;</p>"
        ]
      ]
      1 => array:7 [
        "identificador" => "fig0010"
        "etiqueta" => "Figure 2"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr2.jpeg"
            "Alto" => 646
            "Ancho" => 971
            "Tamanyo" => 37918
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0050" class="elsevierStyleSimplePara elsevierViewall">Changes in heart rate after esmolol administration&#46; HR&#58; heart rate&#46;</p>"
        ]
      ]
      2 => array:7 [
        "identificador" => "fig0015"
        "etiqueta" => "Figure 3"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr3.jpeg"
            "Alto" => 385
            "Ancho" => 949
            "Tamanyo" => 33113
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0055" class="elsevierStyleSimplePara elsevierViewall">Improvement in primary efficacy endpoint &#40;heart rate &#60;65 bpm&#41; when intravenous esmolol was added to the heart rate reduction protocol&#46; CCTA&#58; cardiac computed tomography angiography&#59; HR&#58; heart rate&#46;</p>"
        ]
      ]
      3 => array:7 [
        "identificador" => "fig0020"
        "etiqueta" => "Figure 4"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr4.jpeg"
            "Alto" => 542
            "Ancho" => 1631
            "Tamanyo" => 59413
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0060" class="elsevierStyleSimplePara elsevierViewall">Changes in &#40;A&#41; systolic and &#40;B&#41; diastolic blood pressure after esmolol administration&#46;</p>"
        ]
      ]
      4 => array:8 [
        "identificador" => "tbl0005"
        "etiqueta" => "Table 1"
        "tipo" => "MULTIMEDIATABLA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "detalles" => array:1 [
          0 => array:3 [
            "identificador" => "at1"
            "detalle" => "Table "
            "rol" => "short"
          ]
        ]
        "tabla" => array:2 [
          "leyenda" => "<p id="spar0070" class="elsevierStyleSimplePara elsevierViewall">BMI&#58; body mass index&#59; CABG&#58; coronary artery bypass grafting&#59; MI&#58; myocardial infarction&#59; PCI&#58; percutaneous coronary intervention&#46;</p>"
          "tablatextoimagen" => array:1 [
            0 => array:2 [
              "tabla" => array:1 [
                0 => """
                  <table border="0" frame="\n
                  \t\t\t\t\tvoid\n
                  \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><th class="td" title="table-head  " align="" valign="top" scope="col" style="border-bottom: 2px solid black">&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="left" valign="top" scope="col" style="border-bottom: 2px solid black">Esmolol&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="left" valign="top" scope="col" style="border-bottom: 2px solid black">No esmolol&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Age &#40;years&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">60&#46;9&#177;13&#46;8&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">61&#46;5&#177;13&#46;7&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Male&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">54&#46;0&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">52&#46;9&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Weight &#40;kg&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">73&#46;9&#177;13&#46;7&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">75&#46;4&#177;14&#46;3&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">BMI &#40;kg&#47;m<span class="elsevierStyleSup">2</span>&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">27&#46;40&#177;4&#46;42&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">23&#46;7&#177;2&#46;7&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Hypertension&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">69&#46;6&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">73&#46;5&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Diabetes&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">27&#46;7&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">26&#46;5&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Dyslipidemia&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">68&#46;6&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">66&#46;9&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Current smoker&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">14&#46;5&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">12&#46;5&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Previous MI&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">18&#46;7&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">12&#46;5&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Previous PCI&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">17&#46;9&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">14&#46;0&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Previous CABG&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">16&#46;9&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">8&#46;1&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Previous beta-blockers&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">55&#46;3&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">45&#46;6&#37;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr></tbody></table>
                  """
              ]
              "imagenFichero" => array:1 [
                0 => "xTab1338723.png"
              ]
            ]
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0065" class="elsevierStyleSimplePara elsevierViewall">Clinical characteristics of patients receiving and not receiving esmolol&#46;</p>"
        ]
      ]
    ]
    "bibliografia" => array:2 [
      "titulo" => "References"
      "seccion" => array:1 [
        0 => array:2 [
          "identificador" => "bibs0005"
          "bibliografiaReferencia" => array:22 [
            0 => array:3 [
              "identificador" => "bib0115"
              "etiqueta" => "1"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Noninvasive coronary angiography with 64-section CT&#58; effect of average heart rate and heart rate variability on image quality"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "S&#46; Leschka"
                            1 => "S&#46; Wildermuth"
                            2 => "T&#46; Boehm"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1148/radiol.2412051384"
                      "Revista" => array:6 [
                        "tituloSerie" => "Radiology"
                        "fecha" => "2006"
                        "volumen" => "241"
                        "paginaInicial" => "378"
                        "paginaFinal" => "385"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/16966483"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            1 => array:3 [
              "identificador" => "bib0120"
              "etiqueta" => "2"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Noninvasive coronary angiography using 64-slice spiral computed tomography in an unselected patient collective&#58; effect of heart rate&#44; heart rate variability and coronary calcifications on image quality and diagnostic accuracy"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "H&#46; Brodoefel"
                            1 => "A&#46; Reimann"
                            2 => "C&#46; Burgstahler"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.ejrad.2007.05.013"
                      "Revista" => array:6 [
                        "tituloSerie" => "Eur J Radiol"
                        "fecha" => "2008"
                        "volumen" => "66"
                        "paginaInicial" => "134"
                        "paginaFinal" => "141"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/17600648"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            2 => array:3 [
              "identificador" => "bib0125"
              "etiqueta" => "3"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Noninvasive coronary angiography with 16-detector row CT&#58; effect of heart rate"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "M&#46;H&#46; Hoffmann"
                            1 => "H&#46; Shi"
                            2 => "R&#46; Manzke"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1148/radiol.2341031408"
                      "Revista" => array:6 [
                        "tituloSerie" => "Radiology"
                        "fecha" => "2005"
                        "volumen" => "234"
                        "paginaInicial" => "86"
                        "paginaFinal" => "97"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/15550373"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            3 => array:3 [
              "identificador" => "bib0130"
              "etiqueta" => "4"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Contraindications and side effects of commonly used medications in coronary CT angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "M&#46; Khan"
                            1 => "K&#46;W&#46; Cummings"
                            2 => "F&#46;R&#46; Gutierrez"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1007/s10554-010-9654-8"
                      "Revista" => array:6 [
                        "tituloSerie" => "Int J Cardiovasc Imaging"
                        "fecha" => "2011"
                        "volumen" => "27"
                        "paginaInicial" => "441"
                        "paginaFinal" => "449"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20571874"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            4 => array:3 [
              "identificador" => "bib0135"
              "etiqueta" => "5"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Improvement of image quality with beta-blocker premedication on ECG-gated 16-MDCT coronary angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "S&#46;S&#46; Shim"
                            1 => "Y&#46; Kim"
                            2 => "S&#46;M&#46; Lim"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.2214/ajr.184.2.01840649"
                      "Revista" => array:6 [
                        "tituloSerie" => "AJR Am J Roentgenol"
                        "fecha" => "2005"
                        "volumen" => "184"
                        "paginaInicial" => "649"
                        "paginaFinal" => "654"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/15671392"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            5 => array:3 [
              "identificador" => "bib0140"
              "etiqueta" => "6"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography&#58; experience in 94 patients"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "S&#46; Schroeder"
                            1 => "A&#46;F&#46; Kopp"
                            2 => "A&#46; Kuettner"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Clin Imaging"
                        "fecha" => "2002"
                        "volumen" => "26"
                        "paginaInicial" => "106"
                        "paginaFinal" => "111"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11852217"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            6 => array:3 [
              "identificador" => "bib0145"
              "etiqueta" => "7"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Safety&#44; efficacy&#44; and indications of beta-adrenergic receptor blockade to reduce heart rate prior to coronary CT angiography"
                      "autores" => array:1 [
                        0 => array:3 [
                          "colaboracion" => "Working group &#8220;Cardiac CT&#8221; of the German Cardiac Society"
                          "etal" => true
                          "autores" => array:3 [
                            0 => "A&#46;A&#46; Mahabadi"
                            1 => "S&#46; Achenbach"
                            2 => "C&#46; Burgstahler"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1148/radiol.10100140"
                      "Revista" => array:6 [
                        "tituloSerie" => "Radiology"
                        "fecha" => "2010"
                        "volumen" => "257"
                        "paginaInicial" => "614"
                        "paginaFinal" => "623"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/21084413"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            7 => array:3 [
              "identificador" => "bib0150"
              "etiqueta" => "8"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Efficacy of pre-scan beta-blockade and impact of heart rate on image quality in patients undergoing coronary multidetector computed tomography angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "M&#46;D&#46; Shapiro"
                            1 => "A&#46;J&#46; Pena"
                            2 => "J&#46;H&#46; Nichols"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.ejrad.2007.05.006"
                      "Revista" => array:6 [
                        "tituloSerie" => "Eur J Radiol"
                        "fecha" => "2008"
                        "volumen" => "66"
                        "paginaInicial" => "37"
                        "paginaFinal" => "41"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/17587526"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            8 => array:3 [
              "identificador" => "bib0155"
              "etiqueta" => "9"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Evaluation of the effectiveness of oral beta-blockade in patients for coronary computed tomographic angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "H&#46;K&#46; Pannu"
                            1 => "C&#46; Sullivan"
                            2 => "S&#46; Lai"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1097/RCT.0b013e318075e759"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Comput Assist Tomogr"
                        "fecha" => "2008"
                        "volumen" => "32"
                        "paginaInicial" => "247"
                        "paginaFinal" => "251"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18379311"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            9 => array:3 [
              "identificador" => "bib0160"
              "etiqueta" => "10"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Safety and efficacy of patient preparation with intravenous esmolol before 64-slice computed tomography coronary angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "M&#46; Degertekin"
                            1 => "G&#46; Gemici"
                            2 => "Z&#46; Kaya"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1097/MCA.0b013e3282f27c20"
                      "Revista" => array:6 [
                        "tituloSerie" => "Coron Artery Dis"
                        "fecha" => "2008"
                        "volumen" => "19"
                        "paginaInicial" => "33"
                        "paginaFinal" => "36"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18281813"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            10 => array:3 [
              "identificador" => "bib0165"
              "etiqueta" => "11"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Safety and efficacy of intravenous esmolol before prospective electrocardiogram-triggered high-pitch spiral acquisition for computed tomography coronary angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "J&#46;D&#46; Wang"
                            1 => "H&#46;W&#46; Zhang"
                            2 => "Q&#46; Xin"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.3969/j.issn.1671-5411.2014.01.011"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Geriatr Cardiol"
                        "fecha" => "2014"
                        "volumen" => "11"
                        "paginaInicial" => "39"
                        "paginaFinal" => "43"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24748880"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            11 => array:3 [
              "identificador" => "bib0170"
              "etiqueta" => "12"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Esmolol is noninferior to metoprolol in achieving a target heart rate of 65 beats&#47;min in patients referred to coronary CT angiography&#58; a randomized controlled clinical trial"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "P&#46; Maurovich-Horvat"
                            1 => "M&#46; K&#225;rolyi"
                            2 => "T&#46; Horv&#225;th"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.jcct.2015.02.001"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Cardiovasc Comput Tomogr"
                        "fecha" => "2015"
                        "volumen" => "9"
                        "paginaInicial" => "139"
                        "paginaFinal" => "145"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25819196"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            12 => array:3 [
              "identificador" => "bib0175"
              "etiqueta" => "13"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "64-MDCT angiography of the coronary arteries&#58; nationwide survey of patient preparation practice"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "P&#46;T&#46; Johnson"
                            1 => "J&#46; Eng"
                            2 => "H&#46;K&#46; Pannu"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.2214/AJR.07.2620"
                      "Revista" => array:6 [
                        "tituloSerie" => "AJR Am J Roentgenol"
                        "fecha" => "2008"
                        "volumen" => "190"
                        "paginaInicial" => "743"
                        "paginaFinal" => "747"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18287447"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            13 => array:3 [
              "identificador" => "bib0180"
              "etiqueta" => "14"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "High-dose intravenous metoprolol usage for reducing heart rate at CT coronary angiography&#58; efficacy and safety"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "V&#46;M&#46; Raju"
                            1 => "O&#46;E&#46; Gosling"
                            2 => "G&#46; Morgan-Hughes"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.crad.2014.03.003"
                      "Revista" => array:6 [
                        "tituloSerie" => "Clin Radiol"
                        "fecha" => "2014"
                        "volumen" => "69"
                        "paginaInicial" => "739"
                        "paginaFinal" => "744"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24824980"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            14 => array:3 [
              "identificador" => "bib0185"
              "etiqueta" => "15"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "&#8220;In-house&#8221; pharmacological management for computed tomography coronary angiography&#58; heart rate reduction&#44; timing and safety of different drugs used during patient preparation"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "E&#46; Maffei"
                            1 => "A&#46;A&#46; Palumbo"
                            2 => "C&#46; Martini"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1007/s00330-009-1509-0"
                      "Revista" => array:6 [
                        "tituloSerie" => "Eur Radiol"
                        "fecha" => "2009"
                        "volumen" => "19"
                        "paginaInicial" => "2931"
                        "paginaFinal" => "2940"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/19597820"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            15 => array:3 [
              "identificador" => "bib0190"
              "etiqueta" => "16"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Safety and efficacy of oral ivabradine as a heart rate-reducing agent in patients undergoing CT coronary angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "K&#46;K&#46; Adile"
                            1 => "A&#46; Kapoor"
                            2 => "S&#46;K&#46; Jain"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1259/bjr/22102914"
                      "Revista" => array:6 [
                        "tituloSerie" => "Br J Radiol"
                        "fecha" => "2012"
                        "volumen" => "85"
                        "paginaInicial" => "e424"
                        "paginaFinal" => "e428"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22815422"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            16 => array:3 [
              "identificador" => "bib0195"
              "etiqueta" => "17"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Intravenous ivabradine for control of heart rate during coronary CT angiography&#58; a randomized&#44; double-blind&#44; placebo-controlled trial"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "F&#46; Cademartiri"
                            1 => "J&#46; Garot"
                            2 => "M&#46; Tendera"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.jcct.2015.04.005"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Cardiovasc Comput Tomogr"
                        "fecha" => "2015"
                        "volumen" => "9"
                        "paginaInicial" => "286"
                        "paginaFinal" => "294"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26088378"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            17 => array:3 [
              "identificador" => "bib0200"
              "etiqueta" => "18"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Evaluation of contraindications and efficacy of oral beta blockade before computed tomographic coronary angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "F&#46;R&#46; de Graaf"
                            1 => "J&#46;D&#46; Schuijf"
                            2 => "J&#46;E&#46; van Velzen"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.amjcard.2009.10.058"
                      "Revista" => array:6 [
                        "tituloSerie" => "Am J Cardiol"
                        "fecha" => "2010"
                        "volumen" => "105"
                        "paginaInicial" => "767"
                        "paginaFinal" => "772"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20211317"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            18 => array:3 [
              "identificador" => "bib0205"
              "etiqueta" => "19"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Failed heart rate control with oral metoprolol prior to coronary CT angiography&#58; effect of additional intravenous metoprolol on heart rate&#44; image quality and radiation dose"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "L&#46; Jim&#233;nez-Juan"
                            1 => "E&#46;T&#46; Nguyen"
                            2 => "B&#46;J&#46; Wintersperger"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1007/s10554-012-0049-x"
                      "Revista" => array:6 [
                        "tituloSerie" => "Int J Cardiovasc Imaging"
                        "fecha" => "2013"
                        "volumen" => "29"
                        "paginaInicial" => "199"
                        "paginaFinal" => "206"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22527260"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            19 => array:3 [
              "identificador" => "bib0210"
              "etiqueta" => "20"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Effective radiation dose of three diagnostic tests in cardiology&#58; single photon emission computed tomography&#44; invasive coronary angiography and cardiac computed tomography angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "P&#46; de Ara&#250;jo Gon&#231;alves"
                            1 => "P&#46; Jer&#243;nimo Sousa"
                            2 => "R&#46; Cal&#233;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.repc.2013.05.005"
                      "Revista" => array:6 [
                        "tituloSerie" => "Rev Port Cardiol"
                        "fecha" => "2013"
                        "volumen" => "32"
                        "paginaInicial" => "981"
                        "paginaFinal" => "986"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24287017"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            20 => array:3 [
              "identificador" => "bib0215"
              "etiqueta" => "21"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Dual-source CT coronary angiography without heart rate or rhythm control in comparison with conventional coronary angiography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "X&#46;M&#46; Fang"
                            1 => "H&#46;W&#46; Chen"
                            2 => "X&#46;Y&#46; Hu"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1007/s10554-010-9686-0"
                      "Revista" => array:6 [
                        "tituloSerie" => "Int J Cardiovasc Imaging"
                        "fecha" => "2010"
                        "volumen" => "26"
                        "paginaInicial" => "323"
                        "paginaFinal" => "331"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20730495"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            21 => array:3 [
              "identificador" => "bib0220"
              "etiqueta" => "22"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:3 [
                            0 => "S&#46; Achenbach"
                            1 => "M&#46; Marwan"
                            2 => "D&#46; Ropers"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1093/eurheartj/ehp470"
                      "Revista" => array:6 [
                        "tituloSerie" => "Eur Heart J"
                        "fecha" => "2010"
                        "volumen" => "31"
                        "paginaInicial" => "340"
                        "paginaFinal" => "346"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/19897497"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
          ]
        ]
      ]
    ]
  ]
  "idiomaDefecto" => "en"
  "url" => "/21742049/0000003500000012/v2_201702040044/S2174204916302008/v2_201702040044/en/main.assets"
  "Apartado" => array:4 [
    "identificador" => "9917"
    "tipo" => "SECCION"
    "en" => array:2 [
      "titulo" => "Original Articles"
      "idiomaDefecto" => true
    ]
    "idiomaDefecto" => "en"
  ]
  "PDF" => "https://static.elsevier.es/multimedia/21742049/0000003500000012/v2_201702040044/S2174204916302008/v2_201702040044/en/main.pdf?idApp=UINPBA00004E&text.app=https://revportcardiol.org/"
  "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204916302008?idApp=UINPBA00004E"
]
Article information
ISSN: 21742049
Original language: English
The statistics are updated each day
Year/Month Html Pdf Total
2024 November 9 6 15
2024 October 52 33 85
2024 September 63 34 97
2024 August 52 32 84
2024 July 54 29 83
2024 June 49 28 77
2024 May 48 24 72
2024 April 43 30 73
2024 March 44 27 71
2024 February 37 27 64
2024 January 32 29 61
2023 December 22 27 49
2023 November 42 35 77
2023 October 24 19 43
2023 September 25 23 48
2023 August 32 23 55
2023 July 18 17 35
2023 June 28 17 45
2023 May 56 35 91
2023 April 28 7 35
2023 March 36 29 65
2023 February 26 23 49
2023 January 23 24 47
2022 December 46 23 69
2022 November 48 33 81
2022 October 30 27 57
2022 September 34 43 77
2022 August 40 38 78
2022 July 40 44 84
2022 June 29 34 63
2022 May 25 24 49
2022 April 36 42 78
2022 March 28 48 76
2022 February 27 42 69
2022 January 26 31 57
2021 December 24 39 63
2021 November 33 42 75
2021 October 30 48 78
2021 September 31 33 64
2021 August 29 34 63
2021 July 16 35 51
2021 June 26 26 52
2021 May 35 42 77
2021 April 61 45 106
2021 March 51 41 92
2021 February 43 24 67
2021 January 35 20 55
2020 December 29 7 36
2020 November 24 11 35
2020 October 35 16 51
2020 September 52 16 68
2020 August 15 10 25
2020 July 45 20 65
2020 June 31 11 42
2020 May 46 18 64
2020 April 33 12 45
2020 March 32 7 39
2020 February 131 22 153
2020 January 35 6 41
2019 December 35 4 39
2019 November 29 6 35
2019 October 22 5 27
2019 September 18 11 29
2019 August 20 6 26
2019 July 38 10 48
2019 June 27 16 43
2019 May 41 10 51
2019 April 17 17 34
2019 March 13 11 24
2019 February 57 6 63
2019 January 58 4 62
2018 December 40 9 49
2018 November 118 12 130
2018 October 224 15 239
2018 September 65 13 78
2018 August 24 6 30
2018 July 20 4 24
2018 June 32 2 34
2018 May 46 5 51
2018 April 60 5 65
2018 March 82 10 92
2018 February 47 5 52
2018 January 80 7 87
2017 December 150 14 164
2017 November 61 11 72
2017 October 42 9 51
2017 September 31 12 43
2017 August 41 11 52
2017 July 26 9 35
2017 June 46 19 65
2017 May 39 8 47
2017 April 34 4 38
2017 March 36 6 42
2017 February 54 6 60
2017 January 30 11 41
2016 December 28 11 39
Show all

Follow this link to access the full text of the article

Idiomas
Revista Portuguesa de Cardiologia (English edition)
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

By checking that you are a health professional, you are stating that you are aware and accept that the Portuguese Journal of Cardiology (RPC) is the Data Controller that processes the personal information of users of its website, with its registered office at Campo Grande, n.º 28, 13.º, 1700-093 Lisbon, telephone 217 970 685 and 217 817 630, fax 217 931 095, and email revista@spc.pt. I declare for all purposes that the information provided herein is accurate and correct.