array:24 [
  "pii" => "S2174204918300564"
  "issn" => "21742049"
  "doi" => "10.1016/j.repce.2018.03.005"
  "estado" => "S300"
  "fechaPublicacion" => "2018-02-01"
  "aid" => "1136"
  "copyright" => "Sociedade Portuguesa de Cardiologia"
  "copyrightAnyo" => "2017"
  "documento" => "article"
  "crossmark" => 1
  "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
  "subdocumento" => "sco"
  "cita" => "Rev Port Cardiol. 2018;37:209-10"
  "abierto" => array:3 [
    "ES" => true
    "ES2" => true
    "LATM" => true
  ]
  "gratuito" => true
  "lecturas" => array:2 [
    "total" => 1068
    "formatos" => array:3 [
      "EPUB" => 113
      "HTML" => 741
      "PDF" => 214
    ]
  ]
  "itemSiguiente" => array:18 [
    "pii" => "S2174204918300539"
    "issn" => "21742049"
    "doi" => "10.1016/j.repce.2018.03.002"
    "estado" => "S300"
    "fechaPublicacion" => "2018-02-01"
    "aid" => "1171"
    "documento" => "simple-article"
    "crossmark" => 0
    "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
    "subdocumento" => "prv"
    "cita" => "Rev Port Cardiol. 2018;37:211"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 894
      "formatos" => array:3 [
        "EPUB" => 129
        "HTML" => 566
        "PDF" => 199
      ]
    ]
    "en" => array:9 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Recommended Article of the Month</span>"
      "titulo" => "Brief Comment Video to the Recommended Article of the Month"
      "tienePdf" => "en"
      "tieneTextoCompleto" => "en"
      "paginas" => array:1 [
        0 => array:1 [
          "paginaInicial" => "211"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "pt" => array:1 [
          "titulo" => "Breve Coment&#225;rio V&#237;deo ao Artigo Recomendado do M&#234;s"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "en" => true
      ]
      "contienePdf" => array:1 [
        "en" => true
      ]
    ]
    "idiomaDefecto" => "en"
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204918300539?idApp=UINPBA00004E"
    "url" => "/21742049/0000003700000002/v1_201803200458/S2174204918300539/v1_201803200458/en/main.assets"
  ]
  "itemAnterior" => array:19 [
    "pii" => "S2174204918300576"
    "issn" => "21742049"
    "doi" => "10.1016/j.repce.2018.03.006"
    "estado" => "S300"
    "fechaPublicacion" => "2018-02-01"
    "aid" => "1137"
    "copyright" => "Sociedade Portuguesa de Cardiologia"
    "documento" => "article"
    "crossmark" => 1
    "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
    "subdocumento" => "sco"
    "cita" => "Rev Port Cardiol. 2018;37:205-7"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 1560
      "formatos" => array:3 [
        "EPUB" => 98
        "HTML" => 1249
        "PDF" => 213
      ]
    ]
    "en" => array:11 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Image in Cardiology</span>"
      "titulo" => "Transbrachial intra-aortic balloon pump before urgent coronary artery bypass graft in a patient with severe peripheral atherosclerosis"
      "tienePdf" => "en"
      "tieneTextoCompleto" => "en"
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "205"
          "paginaFinal" => "207"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "pt" => array:1 [
          "titulo" => "Implanta&#231;&#227;o de bal&#227;o intra-a&#243;rtico por via braquial antes de cirurgia urgente de revasculariza&#231;&#227;o coron&#225;ria num doente com aterosclerose perif&#233;rica grave"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "en" => true
      ]
      "contienePdf" => array:1 [
        "en" => true
      ]
      "resumenGrafico" => array:2 [
        "original" => 0
        "multimedia" => array:7 [
          "identificador" => "fig0010"
          "etiqueta" => "Figure 2"
          "tipo" => "MULTIMEDIAFIGURA"
          "mostrarFloat" => true
          "mostrarDisplay" => false
          "figura" => array:1 [
            0 => array:4 [
              "imagen" => "gr2.jpeg"
              "Alto" => 1313
              "Ancho" => 2333
              "Tamanyo" => 385628
            ]
          ]
          "descripcion" => array:1 [
            "en" => "<p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">&#40;a&#41; Fluoroscopy reconstruction showing antegrade placement of an intra-aortic balloon pump at the descending aorta with the proximal radiopaque marker distal to the emergence of the subclavian artery &#40;blue arrow&#41;&#46; &#40;b&#41; Bedside chest X-ray on postoperative day 1 &#40;balloon pump position is highlighted in blue&#41;&#46; &#40;c&#41; Effective 1&#58;2 counterpulsation through 7 Fr transbrachial access&#46;</p>"
          ]
        ]
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "Laura Alvarez-Roy, Tom&#225;s Benito-Gonz&#225;lez, Armando P&#233;rez de Prado, Javier Gualis Cardona, Samuel del Castillo, Felipe Fern&#225;ndez-V&#225;zquez"
          "autores" => array:6 [
            0 => array:2 [
              "nombre" => "Laura"
              "apellidos" => "Alvarez-Roy"
            ]
            1 => array:2 [
              "nombre" => "Tom&#225;s"
              "apellidos" => "Benito-Gonz&#225;lez"
            ]
            2 => array:2 [
              "nombre" => "Armando"
              "apellidos" => "P&#233;rez de Prado"
            ]
            3 => array:2 [
              "nombre" => "Javier"
              "apellidos" => "Gualis Cardona"
            ]
            4 => array:2 [
              "nombre" => "Samuel"
              "apellidos" => "del Castillo"
            ]
            5 => array:2 [
              "nombre" => "Felipe"
              "apellidos" => "Fern&#225;ndez-V&#225;zquez"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "en"
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204918300576?idApp=UINPBA00004E"
    "url" => "/21742049/0000003700000002/v1_201803200458/S2174204918300576/v1_201803200458/en/main.assets"
  ]
  "en" => array:15 [
    "idiomaDefecto" => true
    "cabecera" => "<span class="elsevierStyleTextfn">Image in Cardiology</span>"
    "titulo" => "An extremely rare but considerably important device-related complication of percutaneous atrial septal defect closure"
    "tieneTextoCompleto" => true
    "paginas" => array:1 [
      0 => array:2 [
        "paginaInicial" => "209"
        "paginaFinal" => "210"
      ]
    ]
    "autores" => array:1 [
      0 => array:4 [
        "autoresLista" => "Yusuf I&#46; Alihanoglu, Dogu I&#46; Kilic, Bekir S&#46; Yildiz, Bilgin Emrecan, Harun Evrengul"
        "autores" => array:5 [
          0 => array:4 [
            "nombre" => "Yusuf I&#46;"
            "apellidos" => "Alihanoglu"
            "email" => array:1 [
              0 => "aliizyu&#64;mynet&#46;com"
            ]
            "referencia" => array:2 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "aff0005"
              ]
              1 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">&#42;</span>"
                "identificador" => "cor0005"
              ]
            ]
          ]
          1 => array:3 [
            "nombre" => "Dogu I&#46;"
            "apellidos" => "Kilic"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "aff0005"
              ]
            ]
          ]
          2 => array:3 [
            "nombre" => "Bekir S&#46;"
            "apellidos" => "Yildiz"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "aff0005"
              ]
            ]
          ]
          3 => array:3 [
            "nombre" => "Bilgin"
            "apellidos" => "Emrecan"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">b</span>"
                "identificador" => "aff0010"
              ]
            ]
          ]
          4 => array:3 [
            "nombre" => "Harun"
            "apellidos" => "Evrengul"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "aff0005"
              ]
            ]
          ]
        ]
        "afiliaciones" => array:2 [
          0 => array:3 [
            "entidad" => "Pamukkale University School of Medicine&#44; Department of Cardiology&#44; Denizli&#44; Turkey"
            "etiqueta" => "a"
            "identificador" => "aff0005"
          ]
          1 => array:3 [
            "entidad" => "Pamukkale University School of Medicine&#44; Department of Cardiovascular Surgery&#44; Denizli&#44; Turkey"
            "etiqueta" => "b"
            "identificador" => "aff0010"
          ]
        ]
        "correspondencia" => array:1 [
          0 => array:3 [
            "identificador" => "cor0005"
            "etiqueta" => "&#8270;"
            "correspondencia" => "Corresponding author&#46;"
          ]
        ]
      ]
    ]
    "titulosAlternativos" => array:1 [
      "pt" => array:1 [
        "titulo" => "Uma complica&#231;&#227;o extremamente rara mas consideravelmente importante relacionada com dispositivo de encerramento percut&#226;neo da comunica&#231;&#227;o interauricular"
      ]
    ]
    "resumenGrafico" => array:2 [
      "original" => 0
      "multimedia" => array:7 [
        "identificador" => "fig0010"
        "etiqueta" => "Figure 2"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr2.jpeg"
            "Alto" => 593
            "Ancho" => 950
            "Tamanyo" => 140298
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">Intraoperative imaging showing that all margins of the occluder device were properly attached to the interatrial septum and there was no displacement&#46;</p>"
        ]
      ]
    ]
    "textoCompleto" => "<span class="elsevierStyleSections"><p id="par0005" class="elsevierStylePara elsevierViewall">A 21-year-old male with a 27-mm atrial septal defect &#40;ASD&#41; underwent an uneventful percutaneous device closure using a 28-mm Ultrasept ASD Occluder with super-low profile &#40;Cardia&#44; Inc&#46;&#44; USA&#41; under transoesophageal echocardiography &#40;TEE&#41; guidance&#46; We particularly favoured this kind of occluder device due to the possible future need for catheter atrial septostomy in such a young patient&#46; The use of TEE during the procedure ensured that the occluder device was properly deployed in the middle part of the interatrial septum and there was no residual shunt through it &#40;<a class="elsevierStyleCrossRef" href="#fig0005">Figure 1</a>&#41;&#46; There were also no problems with the occluder device at 1-month follow-up&#46; However&#44; four months after the procedure&#44; the patient presented again with vague chest pain&#44; palpitations and shortness of breath&#46; The physical examination was unremarkable&#46; Transthoracic echocardiography &#40;TTE&#41;&#44; followed by TEE&#44; revealed a significant left-to-right shunt&#44; although the device was clearly seen in the middle part of the interatrial septum&#46; The initial differential diagnosis included partial displacement of the device and therefore&#44; the patient was referred to surgery&#44; all margins of the occluder device were found to be properly attached to the interatrial septum during the surgery &#40;<a class="elsevierStyleCrossRef" href="#fig0010">Figure 2</a>&#41;&#46; Interestingly&#44; the central patch of the device had almost completely disappeared &#40;<a class="elsevierStyleCrossRef" href="#fig0015">Figure 3</a>&#41;&#46; Surgical repair of the atrial septum was performed successfully after removing the metallic part of the device&#46; There were no signs of emboli in the brain or pulmonary vasculature on the computed tomography scan&#44; which was performed following the surgery for any possible embolisation of the patch material&#46; The patient was discharged from the hospital without any complications and in good health&#46;</p><elsevierMultimedia ident="fig0005"></elsevierMultimedia><elsevierMultimedia ident="fig0010"></elsevierMultimedia><elsevierMultimedia ident="fig0015"></elsevierMultimedia><p id="par0010" class="elsevierStylePara elsevierViewall">In conclusion&#44; although device closure of ASDs can safely be performed percutaneously&#44; recanalisation may occur on rare occasions&#44; probably due to device characteristics of the Ultrasept ASD Occluder&#46; While ASD occluder devices from this brand are usually preferred due to their super-low profile&#44; this feature of the devices may not provide necessary support and resistance in the interatrial septum&#46; As a matter of fact&#44; the last generation of Ultrasept ASD Occluder devices have an extra layer between the two other layers&#44; indicating this kind of necessity&#46;</p><span id="sec0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0005">Conflicts of interest</span><p id="par0015" class="elsevierStylePara elsevierViewall">The authors have no conflicts of interest to declare&#46;</p></span></span>"
    "textoCompletoSecciones" => array:1 [
      "secciones" => array:1 [
        0 => array:2 [
          "identificador" => "sec0005"
          "titulo" => "Conflicts of interest"
        ]
      ]
    ]
    "pdfFichero" => "main.pdf"
    "tienePdf" => true
    "fechaRecibido" => "2016-11-19"
    "fechaAceptado" => "2016-12-22"
    "multimedia" => array:3 [
      0 => array:7 [
        "identificador" => "fig0005"
        "etiqueta" => "Figure 1"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr1.jpeg"
            "Alto" => 449
            "Ancho" => 1500
            "Tamanyo" => 81108
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">TEE images demonstrate that the occluder device was properly deployed in the middle part of the interatrial septum &#40;A&#41; and there was no residual shunt through it &#40;B&#41;&#46;</p>"
        ]
      ]
      1 => array:7 [
        "identificador" => "fig0010"
        "etiqueta" => "Figure 2"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr2.jpeg"
            "Alto" => 593
            "Ancho" => 950
            "Tamanyo" => 140298
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">Intraoperative imaging showing that all margins of the occluder device were properly attached to the interatrial septum and there was no displacement&#46;</p>"
        ]
      ]
      2 => array:7 [
        "identificador" => "fig0015"
        "etiqueta" => "Figure 3"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr3.jpeg"
            "Alto" => 737
            "Ancho" => 1498
            "Tamanyo" => 232699
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">Imaging of the occluder device after surgical extraction from the front &#40;A&#41; and the back &#40;B&#41; sites&#46;</p>"
        ]
      ]
    ]
  ]
  "idiomaDefecto" => "en"
  "url" => "/21742049/0000003700000002/v1_201803200458/S2174204918300564/v1_201803200458/en/main.assets"
  "Apartado" => array:4 [
    "identificador" => "9915"
    "tipo" => "SECCION"
    "en" => array:2 [
      "titulo" => "Images in cardiology"
      "idiomaDefecto" => true
    ]
    "idiomaDefecto" => "en"
  ]
  "PDF" => "https://static.elsevier.es/multimedia/21742049/0000003700000002/v1_201803200458/S2174204918300564/v1_201803200458/en/main.pdf?idApp=UINPBA00004E&text.app=https://revportcardiol.org/"
  "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204918300564?idApp=UINPBA00004E"
]
Share
Journal Information

Statistics

Follow this link to access the full text of the article

Image in Cardiology
An extremely rare but considerably important device-related complication of percutaneous atrial septal defect closure
Uma complicação extremamente rara mas consideravelmente importante relacionada com dispositivo de encerramento percutâneo da comunicação interauricular
Yusuf I. Alihanoglua,
Corresponding author
aliizyu@mynet.com

Corresponding author.
, Dogu I. Kilica, Bekir S. Yildiza, Bilgin Emrecanb, Harun Evrengula
a Pamukkale University School of Medicine, Department of Cardiology, Denizli, Turkey
b Pamukkale University School of Medicine, Department of Cardiovascular Surgery, Denizli, Turkey
Read
3786
Times
was read the article
1451
Total PDF
2335
Total HTML
Share statistics
 array:24 [
  "pii" => "S2174204918300564"
  "issn" => "21742049"
  "doi" => "10.1016/j.repce.2018.03.005"
  "estado" => "S300"
  "fechaPublicacion" => "2018-02-01"
  "aid" => "1136"
  "copyright" => "Sociedade Portuguesa de Cardiologia"
  "copyrightAnyo" => "2017"
  "documento" => "article"
  "crossmark" => 1
  "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
  "subdocumento" => "sco"
  "cita" => "Rev Port Cardiol. 2018;37:209-10"
  "abierto" => array:3 [
    "ES" => true
    "ES2" => true
    "LATM" => true
  ]
  "gratuito" => true
  "lecturas" => array:2 [
    "total" => 1068
    "formatos" => array:3 [
      "EPUB" => 113
      "HTML" => 741
      "PDF" => 214
    ]
  ]
  "itemSiguiente" => array:18 [
    "pii" => "S2174204918300539"
    "issn" => "21742049"
    "doi" => "10.1016/j.repce.2018.03.002"
    "estado" => "S300"
    "fechaPublicacion" => "2018-02-01"
    "aid" => "1171"
    "documento" => "simple-article"
    "crossmark" => 0
    "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
    "subdocumento" => "prv"
    "cita" => "Rev Port Cardiol. 2018;37:211"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 894
      "formatos" => array:3 [
        "EPUB" => 129
        "HTML" => 566
        "PDF" => 199
      ]
    ]
    "en" => array:9 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Recommended Article of the Month</span>"
      "titulo" => "Brief Comment Video to the Recommended Article of the Month"
      "tienePdf" => "en"
      "tieneTextoCompleto" => "en"
      "paginas" => array:1 [
        0 => array:1 [
          "paginaInicial" => "211"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "pt" => array:1 [
          "titulo" => "Breve Coment&#225;rio V&#237;deo ao Artigo Recomendado do M&#234;s"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "en" => true
      ]
      "contienePdf" => array:1 [
        "en" => true
      ]
    ]
    "idiomaDefecto" => "en"
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204918300539?idApp=UINPBA00004E"
    "url" => "/21742049/0000003700000002/v1_201803200458/S2174204918300539/v1_201803200458/en/main.assets"
  ]
  "itemAnterior" => array:19 [
    "pii" => "S2174204918300576"
    "issn" => "21742049"
    "doi" => "10.1016/j.repce.2018.03.006"
    "estado" => "S300"
    "fechaPublicacion" => "2018-02-01"
    "aid" => "1137"
    "copyright" => "Sociedade Portuguesa de Cardiologia"
    "documento" => "article"
    "crossmark" => 1
    "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
    "subdocumento" => "sco"
    "cita" => "Rev Port Cardiol. 2018;37:205-7"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 1560
      "formatos" => array:3 [
        "EPUB" => 98
        "HTML" => 1249
        "PDF" => 213
      ]
    ]
    "en" => array:11 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Image in Cardiology</span>"
      "titulo" => "Transbrachial intra-aortic balloon pump before urgent coronary artery bypass graft in a patient with severe peripheral atherosclerosis"
      "tienePdf" => "en"
      "tieneTextoCompleto" => "en"
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "205"
          "paginaFinal" => "207"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "pt" => array:1 [
          "titulo" => "Implanta&#231;&#227;o de bal&#227;o intra-a&#243;rtico por via braquial antes de cirurgia urgente de revasculariza&#231;&#227;o coron&#225;ria num doente com aterosclerose perif&#233;rica grave"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "en" => true
      ]
      "contienePdf" => array:1 [
        "en" => true
      ]
      "resumenGrafico" => array:2 [
        "original" => 0
        "multimedia" => array:7 [
          "identificador" => "fig0010"
          "etiqueta" => "Figure 2"
          "tipo" => "MULTIMEDIAFIGURA"
          "mostrarFloat" => true
          "mostrarDisplay" => false
          "figura" => array:1 [
            0 => array:4 [
              "imagen" => "gr2.jpeg"
              "Alto" => 1313
              "Ancho" => 2333
              "Tamanyo" => 385628
            ]
          ]
          "descripcion" => array:1 [
            "en" => "<p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">&#40;a&#41; Fluoroscopy reconstruction showing antegrade placement of an intra-aortic balloon pump at the descending aorta with the proximal radiopaque marker distal to the emergence of the subclavian artery &#40;blue arrow&#41;&#46; &#40;b&#41; Bedside chest X-ray on postoperative day 1 &#40;balloon pump position is highlighted in blue&#41;&#46; &#40;c&#41; Effective 1&#58;2 counterpulsation through 7 Fr transbrachial access&#46;</p>"
          ]
        ]
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "Laura Alvarez-Roy, Tom&#225;s Benito-Gonz&#225;lez, Armando P&#233;rez de Prado, Javier Gualis Cardona, Samuel del Castillo, Felipe Fern&#225;ndez-V&#225;zquez"
          "autores" => array:6 [
            0 => array:2 [
              "nombre" => "Laura"
              "apellidos" => "Alvarez-Roy"
            ]
            1 => array:2 [
              "nombre" => "Tom&#225;s"
              "apellidos" => "Benito-Gonz&#225;lez"
            ]
            2 => array:2 [
              "nombre" => "Armando"
              "apellidos" => "P&#233;rez de Prado"
            ]
            3 => array:2 [
              "nombre" => "Javier"
              "apellidos" => "Gualis Cardona"
            ]
            4 => array:2 [
              "nombre" => "Samuel"
              "apellidos" => "del Castillo"
            ]
            5 => array:2 [
              "nombre" => "Felipe"
              "apellidos" => "Fern&#225;ndez-V&#225;zquez"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "en"
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204918300576?idApp=UINPBA00004E"
    "url" => "/21742049/0000003700000002/v1_201803200458/S2174204918300576/v1_201803200458/en/main.assets"
  ]
  "en" => array:15 [
    "idiomaDefecto" => true
    "cabecera" => "<span class="elsevierStyleTextfn">Image in Cardiology</span>"
    "titulo" => "An extremely rare but considerably important device-related complication of percutaneous atrial septal defect closure"
    "tieneTextoCompleto" => true
    "paginas" => array:1 [
      0 => array:2 [
        "paginaInicial" => "209"
        "paginaFinal" => "210"
      ]
    ]
    "autores" => array:1 [
      0 => array:4 [
        "autoresLista" => "Yusuf I&#46; Alihanoglu, Dogu I&#46; Kilic, Bekir S&#46; Yildiz, Bilgin Emrecan, Harun Evrengul"
        "autores" => array:5 [
          0 => array:4 [
            "nombre" => "Yusuf I&#46;"
            "apellidos" => "Alihanoglu"
            "email" => array:1 [
              0 => "aliizyu&#64;mynet&#46;com"
            ]
            "referencia" => array:2 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "aff0005"
              ]
              1 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">&#42;</span>"
                "identificador" => "cor0005"
              ]
            ]
          ]
          1 => array:3 [
            "nombre" => "Dogu I&#46;"
            "apellidos" => "Kilic"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "aff0005"
              ]
            ]
          ]
          2 => array:3 [
            "nombre" => "Bekir S&#46;"
            "apellidos" => "Yildiz"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "aff0005"
              ]
            ]
          ]
          3 => array:3 [
            "nombre" => "Bilgin"
            "apellidos" => "Emrecan"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">b</span>"
                "identificador" => "aff0010"
              ]
            ]
          ]
          4 => array:3 [
            "nombre" => "Harun"
            "apellidos" => "Evrengul"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "aff0005"
              ]
            ]
          ]
        ]
        "afiliaciones" => array:2 [
          0 => array:3 [
            "entidad" => "Pamukkale University School of Medicine&#44; Department of Cardiology&#44; Denizli&#44; Turkey"
            "etiqueta" => "a"
            "identificador" => "aff0005"
          ]
          1 => array:3 [
            "entidad" => "Pamukkale University School of Medicine&#44; Department of Cardiovascular Surgery&#44; Denizli&#44; Turkey"
            "etiqueta" => "b"
            "identificador" => "aff0010"
          ]
        ]
        "correspondencia" => array:1 [
          0 => array:3 [
            "identificador" => "cor0005"
            "etiqueta" => "&#8270;"
            "correspondencia" => "Corresponding author&#46;"
          ]
        ]
      ]
    ]
    "titulosAlternativos" => array:1 [
      "pt" => array:1 [
        "titulo" => "Uma complica&#231;&#227;o extremamente rara mas consideravelmente importante relacionada com dispositivo de encerramento percut&#226;neo da comunica&#231;&#227;o interauricular"
      ]
    ]
    "resumenGrafico" => array:2 [
      "original" => 0
      "multimedia" => array:7 [
        "identificador" => "fig0010"
        "etiqueta" => "Figure 2"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr2.jpeg"
            "Alto" => 593
            "Ancho" => 950
            "Tamanyo" => 140298
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">Intraoperative imaging showing that all margins of the occluder device were properly attached to the interatrial septum and there was no displacement&#46;</p>"
        ]
      ]
    ]
    "textoCompleto" => "<span class="elsevierStyleSections"><p id="par0005" class="elsevierStylePara elsevierViewall">A 21-year-old male with a 27-mm atrial septal defect &#40;ASD&#41; underwent an uneventful percutaneous device closure using a 28-mm Ultrasept ASD Occluder with super-low profile &#40;Cardia&#44; Inc&#46;&#44; USA&#41; under transoesophageal echocardiography &#40;TEE&#41; guidance&#46; We particularly favoured this kind of occluder device due to the possible future need for catheter atrial septostomy in such a young patient&#46; The use of TEE during the procedure ensured that the occluder device was properly deployed in the middle part of the interatrial septum and there was no residual shunt through it &#40;<a class="elsevierStyleCrossRef" href="#fig0005">Figure 1</a>&#41;&#46; There were also no problems with the occluder device at 1-month follow-up&#46; However&#44; four months after the procedure&#44; the patient presented again with vague chest pain&#44; palpitations and shortness of breath&#46; The physical examination was unremarkable&#46; Transthoracic echocardiography &#40;TTE&#41;&#44; followed by TEE&#44; revealed a significant left-to-right shunt&#44; although the device was clearly seen in the middle part of the interatrial septum&#46; The initial differential diagnosis included partial displacement of the device and therefore&#44; the patient was referred to surgery&#44; all margins of the occluder device were found to be properly attached to the interatrial septum during the surgery &#40;<a class="elsevierStyleCrossRef" href="#fig0010">Figure 2</a>&#41;&#46; Interestingly&#44; the central patch of the device had almost completely disappeared &#40;<a class="elsevierStyleCrossRef" href="#fig0015">Figure 3</a>&#41;&#46; Surgical repair of the atrial septum was performed successfully after removing the metallic part of the device&#46; There were no signs of emboli in the brain or pulmonary vasculature on the computed tomography scan&#44; which was performed following the surgery for any possible embolisation of the patch material&#46; The patient was discharged from the hospital without any complications and in good health&#46;</p><elsevierMultimedia ident="fig0005"></elsevierMultimedia><elsevierMultimedia ident="fig0010"></elsevierMultimedia><elsevierMultimedia ident="fig0015"></elsevierMultimedia><p id="par0010" class="elsevierStylePara elsevierViewall">In conclusion&#44; although device closure of ASDs can safely be performed percutaneously&#44; recanalisation may occur on rare occasions&#44; probably due to device characteristics of the Ultrasept ASD Occluder&#46; While ASD occluder devices from this brand are usually preferred due to their super-low profile&#44; this feature of the devices may not provide necessary support and resistance in the interatrial septum&#46; As a matter of fact&#44; the last generation of Ultrasept ASD Occluder devices have an extra layer between the two other layers&#44; indicating this kind of necessity&#46;</p><span id="sec0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0005">Conflicts of interest</span><p id="par0015" class="elsevierStylePara elsevierViewall">The authors have no conflicts of interest to declare&#46;</p></span></span>"
    "textoCompletoSecciones" => array:1 [
      "secciones" => array:1 [
        0 => array:2 [
          "identificador" => "sec0005"
          "titulo" => "Conflicts of interest"
        ]
      ]
    ]
    "pdfFichero" => "main.pdf"
    "tienePdf" => true
    "fechaRecibido" => "2016-11-19"
    "fechaAceptado" => "2016-12-22"
    "multimedia" => array:3 [
      0 => array:7 [
        "identificador" => "fig0005"
        "etiqueta" => "Figure 1"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr1.jpeg"
            "Alto" => 449
            "Ancho" => 1500
            "Tamanyo" => 81108
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">TEE images demonstrate that the occluder device was properly deployed in the middle part of the interatrial septum &#40;A&#41; and there was no residual shunt through it &#40;B&#41;&#46;</p>"
        ]
      ]
      1 => array:7 [
        "identificador" => "fig0010"
        "etiqueta" => "Figure 2"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr2.jpeg"
            "Alto" => 593
            "Ancho" => 950
            "Tamanyo" => 140298
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">Intraoperative imaging showing that all margins of the occluder device were properly attached to the interatrial septum and there was no displacement&#46;</p>"
        ]
      ]
      2 => array:7 [
        "identificador" => "fig0015"
        "etiqueta" => "Figure 3"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr3.jpeg"
            "Alto" => 737
            "Ancho" => 1498
            "Tamanyo" => 232699
          ]
        ]
        "descripcion" => array:1 [
          "en" => "<p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">Imaging of the occluder device after surgical extraction from the front &#40;A&#41; and the back &#40;B&#41; sites&#46;</p>"
        ]
      ]
    ]
  ]
  "idiomaDefecto" => "en"
  "url" => "/21742049/0000003700000002/v1_201803200458/S2174204918300564/v1_201803200458/en/main.assets"
  "Apartado" => array:4 [
    "identificador" => "9915"
    "tipo" => "SECCION"
    "en" => array:2 [
      "titulo" => "Images in cardiology"
      "idiomaDefecto" => true
    ]
    "idiomaDefecto" => "en"
  ]
  "PDF" => "https://static.elsevier.es/multimedia/21742049/0000003700000002/v1_201803200458/S2174204918300564/v1_201803200458/en/main.pdf?idApp=UINPBA00004E&text.app=https://revportcardiol.org/"
  "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2174204918300564?idApp=UINPBA00004E"
]
Article information
ISSN: 21742049
Original language: English
The statistics are updated each day
Year/Month Html Pdf Total
2024 November 6 7 13
2024 October 29 19 48
2024 September 39 19 58
2024 August 32 22 54
2024 July 28 32 60
2024 June 28 26 54
2024 May 31 30 61
2024 April 30 27 57
2024 March 26 19 45
2024 February 22 18 40
2024 January 33 19 52
2023 December 19 30 49
2023 November 29 19 48
2023 October 21 17 38
2023 September 28 17 45
2023 August 27 16 43
2023 July 28 9 37
2023 June 25 9 34
2023 May 33 18 51
2023 April 27 6 33
2023 March 32 17 49
2023 February 31 21 52
2023 January 25 13 38
2022 December 28 21 49
2022 November 40 20 60
2022 October 36 27 63
2022 September 34 30 64
2022 August 25 30 55
2022 July 29 42 71
2022 June 19 26 45
2022 May 24 20 44
2022 April 32 50 82
2022 March 28 34 62
2022 February 24 42 66
2022 January 36 26 62
2021 December 30 31 61
2021 November 23 32 55
2021 October 32 39 71
2021 September 27 22 49
2021 August 26 36 62
2021 July 18 31 49
2021 June 21 16 37
2021 May 23 36 59
2021 April 28 35 63
2021 March 40 16 56
2021 February 43 17 60
2021 January 13 11 24
2020 December 19 8 27
2020 November 30 13 43
2020 October 14 14 28
2020 September 40 8 48
2020 August 11 11 22
2020 July 38 15 53
2020 June 26 16 42
2020 May 26 11 37
2020 April 24 7 31
2020 March 52 12 64
2020 February 83 19 102
2020 January 30 5 35
2019 December 24 10 34
2019 November 35 6 41
2019 October 21 4 25
2019 September 25 4 29
2019 August 15 7 22
2019 July 30 12 42
2019 June 30 8 38
2019 May 17 6 23
2019 April 14 16 30
2019 March 39 12 51
2019 February 73 8 81
2019 January 24 12 36
2018 December 29 10 39
2018 November 34 11 45
2018 October 40 14 54
2018 September 16 10 26
2018 August 26 4 30
2018 July 11 4 15
2018 June 22 4 26
2018 May 16 7 23
2018 April 55 13 68
2018 March 38 10 48
Show all

Follow this link to access the full text of the article

Idiomas
Revista Portuguesa de Cardiologia (English edition)
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

By checking that you are a health professional, you are stating that you are aware and accept that the Portuguese Journal of Cardiology (RPC) is the Data Controller that processes the personal information of users of its website, with its registered office at Campo Grande, n.º 28, 13.º, 1700-093 Lisbon, telephone 217 970 685 and 217 817 630, fax 217 931 095, and email revista@spc.pt. I declare for all purposes that the information provided herein is accurate and correct.