Aortic arch rescued through double-chimney technique
Tratamento endovascular de aneurisma do arco aórtico pela técnica de double-chimney
Visitas
5563
Liliana Martaa,
Autor para correspondência
liliana.marta@gmail.com

Corresponding author.
, Nuno Bettencourtb, Pedro Bragab, Fábio Pereirac, Vasco Gamab
a Cardiology Department, Hospital de Santarém, Santarém, Portugal
b Cardiology Department, Centro Hospitalar de Vila Nova de Gaia/Espinho, Vila Nova de Gaia, Portugal
c Vascular Surgery Department, Hospital Metropolitano, São Paulo, Brazil
Este item recebeu

Under a Creative Commons license
Informação do artigo
Texto Completo
Baixar PDF
Estatísticas
Figuras (1)
Texto Completo

A 62-year-old man with a history of hypertension, smoking, chronic obstructive pulmonary disease and coronary artery disease had a saccular aneurysm in the distal aortic arch (Figure 1A) involving the origin of the left subclavian artery (LSA), with a maximum diameter of 65 mm and a short proximal neck distancing 13 mm from the origin of the left common carotid artery (LCCA).

Figure 1.

Pre-procedure computed tomography angiography (CTA) showing a large aneurysm in the distal aortic arch involving the origin of the left subclavian artery (A). Follow-up CTA at one month revealed no endoleak and patency of the innominate and LCCA stent grafts (B, C, D).

(0,26MB).

He was considered at high surgical risk and was referred for thoracic endovascular aortic repair with simultaneous preservation of perfusion of the innominate artery and LCCA through double-chimney technique.

The procedure was performed under general anesthesia. A Gore® TAG® stent graft was first inserted through the right common femoral artery and deployed at the distal end of the aneurysm, and a second one was inserted into the ascending aorta distally overlapping with the first. Two Gore® VIABAHN® stent grafts were introduced through the right axillary artery and LCCA and deployed at the proximal edge of the proximal TAG stent graft. Post-procedure computed tomography angiography (CTA) revealed a type II endoleak from the LSA, but follow-up CTA at one month revealed no endoleak and patency of the stent grafts (Figure 1B, C and D).

The double chimney is a recently introduced endovascular technique that provides an alternative to surgical treatment of aortic arch disease with preservation of the arch branches. There are a few case reports worldwide with acceptable short-term results, most associated with lower mortality and stroke rates compared to surgical or hybrid techniques. This case represents the first experience in Portugal with the double-chimney technique and long-term data are awaited.

Ethical disclosuresProtection of human and animal subjects

The authors declare that no experiments were performed on humans or animals for this study.

Confidentiality of data

The authors declare that they have followed the protocols of their work center on the publication of patient data and that all the patients included in the study received sufficient information and gave their written informed consent to participate in the study.

Right to privacy and informed consent

The authors have obtained the written informed consent of the patients or subjects mentioned in the article. The corresponding author is in possession of this document.

Conflicts of interest

The authors have no conflicts of interest to declare.

Copyright © 2014. Sociedade Portuguesa de Cardiologia
Idiomas
Revista Portuguesa de Cardiologia
Opções de artigo
Ferramentas
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Ao assinalar que é «Profissional de Saúde», declara conhecer e aceitar que a responsável pelo tratamento dos dados pessoais dos utilizadores da página de internet da Revista Portuguesa de Cardiologia (RPC), é esta entidade, com sede no Campo Grande, n.º 28, 13.º, 1700-093 Lisboa, com os telefones 217 970 685 e 217 817 630, fax 217 931 095 e com o endereço de correio eletrónico revista@spc.pt. Declaro para todos os fins, que assumo inteira responsabilidade pela veracidade e exatidão da afirmação aqui fornecida.