Informação da revista
Vol. 42. Núm. 4.
Páginas 371-372 (Abril 2023)
Partilhar
Partilhar
Baixar PDF
Mais opções do artigo
Vol. 42. Núm. 4.
Páginas 371-372 (Abril 2023)
Editorial comment
Acesso de texto completo
Simplifying atrial fibrillation ablation, part of the equation to amplify rhythm control accessibility
Simplificando a ablação da fibrilhação auricular, parte da equação para ampliar a acessibilidade ao controlo do ritmo
Visitas
835
Francisco Moscoso Costa
Hospital de Santa Cruz, CHLO, Lisboa, Portugal
Este item recebeu
Informação do artigo
Texto Completo
Bibliografia
Baixar PDF
Estatísticas
Texto Completo

The incidence of atrial fibrillation (AF) will rise in the coming years, mostly due to the aging population and related risk factors. This will significantly increase its social, economic, and healthcare burden among western countries.1 Contemporary AF management comprises three main pillars: stroke prevention, addressing comorbidities and rhythm control strategies. These include interventions such as atrial fibrillation ablation, currently indicated to improve quality of life and, in patients with plausible tachycardiomyopathy, to reduce hospitalization and improve survival.2

In Portugal, the number of AF patients referred for ablation has been increasing consistently3 but is still below the average European ratio of interventions per million inhabitants.4 A recent Portuguese registry of AF patients in a primary care setting highlighted that rhythm control is only considered in a minority of patients and that the most prescribed antiarrhythmic drug was amiodarone.5 Considering recent data on the added value of early rhythm control,6 there is a clear need for improvement, both by promoting better usage of antiarrhythmic drugs and, when appropriate, by referral for AF ablation in a timely manner. To achieve this, AF management must be integrated, referral pathways must be optimized, and electrophysiology (EP) labs need to adapt to deal with the increase in workload while maintaining safety and cost efficiency.

Over the years, cumulative experience plus technological advances such as mapping systems, contact force catheters and single shot devices, have transformed a once long and technically challenging procedure into a more predictable, faster, safer, and more effective one.7 This evolution plays a key role in safely amplifying the number of ablations per center, optimizing EP lab efficiency and addressing the continuous and increasing demand.

In this issue of the Journal, Cunha et al. describe a national, retrospective, four center cohort of 406 patients mostly with paroxysmal AF who underwent pulmonary vein isolation (PVI) using the Arctic Front™ Advance Pro 28mm Cryoballoon (Medtronic Inc, Minneapolis, MN). The scarcity of national data on this single shot device ads to the relevancy of the paper.

The authors describe a mean procedure time of 107.7±50.9 minutes, and a fluoroscopy time of 19.5±9.7 minutes. This is to be expected and in line with published cohorts.8 The simplicity of this single shot device allows for a relatively fast procedure without the need for a mapping system and might be a valuable tool for EP lab optimization. Nevertheless, it is worth discussing that the fluoroscopy time is higher when compared to PVI performed with mapping systems and contact force catheters.9 The implications of these findings, for patients, physicians and other health professionals should not be underestimated, especially with increasing number of procedures in the EP labs.

In an average follow up of 22.0±15.0 months, recurrence rates were 20.5% for paroxysmal AF and 37.8% for persistent AF. These results are aligned with the literature considering PVI only as standard of care. Also, left atrium volume, an established predictor of AF recurrence after PVI,10 was validated in this cohort, highlighting the relevance of the atrium substrate on AF and its implications for disease management. The inability to target non pulmonary vein triggers or left atrium substrate besides PVI is a known limitation of cryoballoon technique that may gain relevance especially when addressing patients with persistent AF.11

When interpreting AF recurrence, it is relevant to consider that the traditional and most frequently used binary (yes/no) classification for recurrence does not enable the reduction in AF burden to be assessed. This may underestimate the real benefit of ablation since even patients with recurrence may have less frequent episodes and improved quality of life, and thus still benefit from the treatment.12 This rationale should be considered during clinical practice both when referring for ablation and during follow up after the procedure.

Perhaps one of the most important findings is the reported rate of severe and life-threatening complications that is low and comparable to the most recent clinical trials.6 The rate of tamponade and vascular complications is <1%, and there were no cases of procedure-related death or stroke. If we consider that most phrenic nerve palsies were in fact transient, the described rate of complications reinforces that in the real world PVI is relatively safe when performed at experienced centers.

Finally, the authors acknowledge one main limitation of this study, that it is retrospective and does not have a clearly defined selection criteria for cryoballoon vs. traditional point-by-point radiofrequency. Indeed, the 406 included patients account for around 25% of the total AF ablations performed during the study period and, besides the usual reasons for not using a single shot device, for instance, prior flutter documentation and need to perform linear lesions, selection bias cannot be excluded.

Electrophysiology labs have been the stage for a technological revolution that has transformed our clinical practice enabling us to treat an increasing number of patients effectively. Currently, the gap is not technological but organizational using, it is time to take a step further, aiming for integrated AF management, enabling general accessibility to standard of care and, when appropriate, to a safe rhythm control strategy.

Conflicts of interest

The author has no conflicts of interest to declare.

References
[1]
B.P. Krijthe, A. Kunst, E.J. Benjamin, et al.
Projections on the number of individuals with atrial fibrillation in the European Union, from 2000 to 2060.
Eur Heart J, 34 (2013), pp. 2746-2751
[2]
G. Hindricks, T. Potpara, N. Dagres, et al.
2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS): The Task Force for the diagnosis and management of atrial fibrillation of the European Society of Cardiology (ESC) developed with the special contribution of the European Heart Rhythm Association (EHRA) of the ESC.
Eur Heart J, 42 (2021), pp. 373-498
[3]
N. Cortez-Dias, P. Silva Cunha, F. Moscoso Costa, et al.
Registo Nacional de Eletrofisiologia Cardíaca 2017-2018.
Rev Port Cardiol, 40 (2021), pp. 119-129
[4]
M.J. Pekka Raatikainen, D. Arnar, B. Merkely, et al.
A decade of information on the use of cardiac implantable electronic devices and interventional electrophysiological procedures in the European Society of Cardiology countries: 2017 report from the European Heart Rhythm Association.
EP Europace, 19 (2017), pp. ii1-ii90
[5]
F.M. Costa, C. Aguiar, D. Caldeira, et al.
X-ray AF: resultados principais do registo de fibrilhação auricular em Portugal continental.
Rev Port Cardiol, 41 (2022), pp. 104
[6]
P. Kirchhof, J. Camm, A. Goette, et al.
Early rhythm-control therapy in patients with atrial fibrillation.
N Engl J Med, 383 (2020), pp. 1305-1316
[7]
G. Hindricks, D.L. Packer.
Catheter ablation of atrial fibrillation: recent advances and future challenges.
EP Europace, 24 (2022), pp. ii1-ii2
[8]
K.R. Julian Chun, K. Okumura, F. Scazzuso, et al.
Safety and efficacy of cryoballoon ablation for the treatment of paroxysmal and persistent AF in a real-world global setting: results from the Cryo AF Global Registry.
J Arrhythm, 37 (2021), pp. 356-367
[9]
L. Fiedler, H. Blessberger, P. Balsam, et al.
Impact of contact force-sensing catheters on fluoroscopy time in interventional electrophysiology: a European survey.
J Clin Med, 11 (2022), pp. 1322
[10]
F.M. Costa, A. Ferreira, S. Oliveira, et al.
Left atrial volume is more important than the type of atrial fibrillation in predicting the long-term success of catheter ablation.
Int J Cardiol, 184 (2015), pp. 56-61
[11]
Y. Huo, T. Gaspar, R. Schonbauer, et al.
Low-voltage myocardium-guided ablation trial of persistent atrial fibrillation.
NEJM Evid, 1 (2022),
[12]
J.G. Andrade, J. Champagne, M. Dubuc, et al.
Cryoballoon or radiofrequency ablation for atrial fibrillation assessed by continuous monitoring. a randomized clinical trial.
Circulation, 140 (2019), pp. 1779-1788
Copyright © 2023. Sociedade Portuguesa de Cardiologia
Idiomas
Revista Portuguesa de Cardiologia
Opções de artigo
Ferramentas
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Ao assinalar que é «Profissional de Saúde», declara conhecer e aceitar que a responsável pelo tratamento dos dados pessoais dos utilizadores da página de internet da Revista Portuguesa de Cardiologia (RPC), é esta entidade, com sede no Campo Grande, n.º 28, 13.º, 1700-093 Lisboa, com os telefones 217 970 685 e 217 817 630, fax 217 931 095 e com o endereço de correio eletrónico revista@spc.pt. Declaro para todos os fins, que assumo inteira responsabilidade pela veracidade e exatidão da afirmação aqui fornecida.