Informação da revista
Vol. 40. Núm. 2.
Páginas 143-144 (Fevereiro 2021)
Partilhar
Partilhar
Baixar PDF
Mais opções do artigo
Vol. 40. Núm. 2.
Páginas 143-144 (Fevereiro 2021)
Image in Cardiology
Open Access
Late challenges after full plastic jacket in spontaneous coronary dissection
Desafios do full plastic jacket na dissecção coronária espontânea
Visitas
2281
Patrícia Marques-Alvesb,
Autor para correspondência
pat.marques.alves@gmail.com

Corresponding author.
, Manuel Oliveira-Santosa,b, João Silva Marquesa, Lino Gonçalvesa,b
a Department of Cardiology, Centro Hospitalar e Universitário de Coimbra, Coimbra, Portugal
b Faculty of Medicine, University of Coimbra, Coimbra, Portugal
Este item recebeu

Under a Creative Commons license
Informação do artigo
Texto Completo
Bibliografia
Baixar PDF
Estatísticas
Figuras (1)
Texto Completo

We report the case of a 38-year-old woman with a complicated spontaneous coronary artery dissection (SCAD) of the right coronary artery treated with sequential bioresorbable vascular scaffolds (BVS) making a ‘full plastic jacket’.1 A good angiographic result was achieved (Figure 1A and B). Optical coherence tomography (OCT) showed slight persistence of the proximal dissection (Figure 1C) that was considered non-significant. At one-year follow-up, the patient was admitted for unstable angina. Angiography showed a contrast-filled perivascular space in the proximal segment (Figure 1D, arrow). On OCT, BVS struts were fractured and prolapsing into the lumen (Figure 1E, arrow) and there was a large false lumen with persistent entry flaps (Figure 1E and F, asterisk, arrow). In order to seal the chronic dissection and deal with the fractured BVS struts, a covered coronary stent was implanted. There was angiographic and OCT success (Figure G and H) without BVS damage at the covered stent margins. After six months, follow-up angiography and OCT imaging confirmed a good result of the intervention (Figure 1I).

Figure 1.

(A) Index right coronary angiography after angioplasty; (B) index optical coherence tomography (OCT) imaging after angioplasty; (C) index OCT imaging with residual proximal dissection covered by stent struts; (D) suspicious lesion, suggestive of a residual dissection/false aneurysm (arrow); (E) proximal BVS stents with a large hematoma (asterisk), overlapped struts and struts protruding into the lumen (arrow); (F) entry flaps of the residual proximal dissection (arrow); (G) final angiographic result after angioplasty; (H) final OCT showing correct stent expansion and sealing of the flaps; (I) six-month follow-up OCT with no signs of stent restenosis.

(0,73MB).

Although initial enthusiasm for BVS has waned after results of more recent clinical trials, complicated SCAD is considered a good indication for their use. This case demonstrates that even in this setting there may be non-acute complications that may not be apparent in a non-invasive clinical follow-up. Based on our findings we suggest a low threshold for angiographic and intravascular imaging assessment. Finally, the use of a covered stent in a case of BVS fracture and chronic dissection was safe and effective.

Conflicts of interest

The authors have no conflicts of interest to declare.

Reference
[1]
A.R. Ramalho, J. Silva Marques, M. Oliveira Santos, V. Matos.
Optical Coherence Tomography–Guided Full Plastic Jacket in Spontaneous Coronary Artery Dissection.
JACC Cardiovasc Interv., 10 (2017), pp. 413-414
Copyright © 2020. Sociedade Portuguesa de Cardiologia
Idiomas
Revista Portuguesa de Cardiologia
Opções de artigo
Ferramentas
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Ao assinalar que é «Profissional de Saúde», declara conhecer e aceitar que a responsável pelo tratamento dos dados pessoais dos utilizadores da página de internet da Revista Portuguesa de Cardiologia (RPC), é esta entidade, com sede no Campo Grande, n.º 28, 13.º, 1700-093 Lisboa, com os telefones 217 970 685 e 217 817 630, fax 217 931 095 e com o endereço de correio eletrónico revista@spc.pt. Declaro para todos os fins, que assumo inteira responsabilidade pela veracidade e exatidão da afirmação aqui fornecida.