Elsevier

Journal of Electrocardiology

Volume 62, September–October 2020, Pages 5-9
Journal of Electrocardiology

Evaluation of electrocardiographic ventricular repolarization variables in patients with newly diagnosed COVID-19

https://doi.org/10.1016/j.jelectrocard.2020.07.005Get rights and content

Highlights

  • Tp-e interval, Tp-e/QT ratio, and Tp-e/QTc ratio prolong in newly diagnosed COVID-19.

  • A positive correlation was determined between repolarization parameters and CRP.

  • Pre-treatment evaluation of repolarization parameters in COVID-19 may be beneficial for predicting arrhythmia risk.

Abstract

Introduction

Coronavirus disease 2019 (COVID-19) is a newly recognized infectious disease that has spread rapidly. COVID-19 has been associated with a number of cardiovascular complications, including arrhythmias. The mechanism of ventricular arrhythmias in patients with COVID-19 is uncertain. The aim of the present study was to evaluate the ventricular repolarization by using the Tp-e interval, QT dispersion, Tp-e/QT ratio, and Tp-e/QTc ratio as candidate markers of ventricular arrhythmias in patients with newly diagnosed COVID-19. In addition, the relationship between the repolarization parameters and the CRP (C-reactive protein) was investigated.

Methods

75 newly diagnosed COVID-19 patients, 75 age and sex matched healthy subjects were included in the study between 20th March 2020 and 10th April 2020. The risk of ventricular arrhythmias was evaluated by calculating the electrocardiographic Tp-e and QT interval, Tp-e dispersion, corrected QT(QTc), QT dispersion (QTd), corrected QTd, Tp-e/QT and Tp-e/QTc ratios. CRP values were also measured in patients with newly diagnosed COVID-19.

Results

Tp-e interval (80.7 ± 4.6 vs. 70.9 ± 4.8; p < .001), Tp-e / QT ratio (0.21 ± 0.01 vs. 0.19 ± 0.01; p < .001) and Tp-e/QTc ratio (0.19 ± 0.01 vs.0.17 ± 0.01; p < .001) were significantly higher in patients with newly diagnosed COVID-19 than the control group. There was a significant positive correlation between Tp-e interval, Tp-e/QTc ratio and CRP in patients with newly diagnosed COVID-19 (rs = 0.332, p = .005, rs = 0.397, p < .001 consecutively). During their treatment with hydroxychloroquine (HCQ), azithromycin and favipiravir, ventricular tachycardia episodes were observed in in two COVID-19 patients during their hospitalization in the intensive care unit.

Conclusion

Our study showed for the first time in literature that the Tp-e interval, Tp-e/QT ratio, and Tp-e/QTc ratio, which are evaluated electrocardiographically in patients with newly diagnosed COVID-19, were prolonged compared with normal healthy individuals. A positive correlation was determined between repolarization parameters and CRP. We believe that pre-treatment evaluation of repolarization parameters in newly diagnosed COVID-19 would be beneficial for predicting ventricular arrhythmia risk.

Keywords

COVID-19
SARS-CoV-2
Tp-e interval
Tp-e/QT ratio
Ventricular arrhythmia

Cited by (0)