Clinical Research
A Prospective Feasibility Trial Investigating the Use of the Impella 2.5 System in Patients Undergoing High-Risk Percutaneous Coronary Intervention (The PROTECT I Trial): Initial U.S. Experience

Presented in part at Transcatheter Cardiovascular Therapeutics 2007, Washington, DC.
https://doi.org/10.1016/j.jcin.2008.11.005Get rights and content
Under an Elsevier user license
open archive

Objectives

We sought to evaluate the safety and feasibility of the Impella 2.5 system (Abiomed Inc., Danvers, Massachusetts) in patients undergoing high-risk percutaneous coronary intervention (PCI).

Background

The Impella 2.5 is a miniaturized percutaneous cardiac assist device, which provides up to 2.5 l/min forward flow from the left ventricle into the systemic circulation.

Methods

In a prospective, multicenter study, 20 patients underwent high-risk PCI with minimally invasive circulatory support employing the Impella 2.5 system. All patients had poor left ventricular function (ejection fraction ≤35%) and underwent PCI on an unprotected left main coronary artery or last patent coronary conduit. Patients with recent ST-segment elevation myocardial infarction or cardiogenic shock were excluded. The primary safety end point was the incidence of major adverse cardiac events at 30 days. The primary efficacy end point was freedom from hemodynamic compromise during PCI (defined as a decrease in mean arterial pressure below 60 mm Hg for >10 min).

Results

The Impella 2.5 device was implanted successfully in all patients. The mean duration of circulatory support was 1.7 ± 0.6 h (range: 0.4 to 2.5 h). Mean pump flow during PCI was 2.2 ± 0.3 l/min. At 30 days, the incidence of major adverse cardiac events was 20% (2 patients had a periprocedural myocardial infarction; 2 patients died at days 12 and 14). There was no evidence of aortic valve injury, cardiac perforation, or limb ischemia. Two patients (10%) developed mild, transient hemolysis without clinical sequelae. None of the patients developed hemodynamic compromise during PCI.

Conclusions

The Impella 2.5 system is safe, easy to implant, and provides excellent hemodynamic support during high-risk PCI. (The PROTECT I Trial; NCT00534859)

Key Words

percutaneous coronary intervention
high risk
circulatory support

Abbreviations and Acronyms

EF
ejection fraction
INR
international normalized ratio
LV
left ventricle/ventricular
PCI
percutaneous coronary intervention

Cited by (0)

Supported by a grant from Abiomed Inc., Danvers, Massachusetts. Dr. Benali is a paid employee of Abiomed Inc.