Informação da revista
Vol. 35. Núm. 7 - 8.
Páginas 449-450 (Julho - Agosto 2016)
Partilhar
Partilhar
Baixar PDF
Mais opções do artigo
Vol. 35. Núm. 7 - 8.
Páginas 449-450 (Julho - Agosto 2016)
Image in Cardiology
Open Access
Right ventricular hematoma
Hematoma do ventrículo direito
Visitas
4442
Rui Plácidoa,
Autor para correspondência
placidorui@gmail.com

Corresponding author.
, João Abecasisb, Susana Gonçalvesa, Fausto J. Pintoa, Ana G. Almeidaa
a Hospital Santa Maria, Serviço Cardiologia I, Lisbon Academic Medical Centre, CCUL, Lisbon, Portugal
b Unidade Cardiovascular, HPP Hospital dos Lusíadas, Lisbon, Portugal
Este item recebeu

Under a Creative Commons license
Informação do artigo
Texto Completo
Baixar PDF
Estatísticas
Figuras (1)
Material adicional (4)
Texto Completo

We present the case of a 65-year-old male referred by an oncologist for transthoracic echocardiography because of effort dyspnea. His past medical history was remarkable for chronic obstructive pulmonary disease (COPD) and a gastric adenocarcinoma (pT2N1M0), resected three years previously and treated by adjuvant chemotherapy. Echocardiography revealed preserved biventricular ejection fraction, normal left ventricular diastolic indices, non-significant valvular dysfunction and no signs of pulmonary hypertension. However, a well-delimited 30 mm×23 mm×24 mm right ventricular (RV) ovoid, isoechogenic and homogeneous mass (Figure 1, asterisk) was observed along the basal free wall, in a sub-tricuspid position, well detached from the right coronary artery course (Figure 1, yellow arrow, and Videos 1 and 2).

Figure 1.

(A) Two-dimensional transthoracic echocardiography, modified short-axis view at the sub-tricuspid level, depicting a well-defined right ventricular mass (*) and part of the right coronary artery course along the atrioventricular groove (arrow); (B) three-dimensional (3D) transthoracic echocardiography, live 3D bird's eye view, modified 4-chamber view, showing a homogeneous and delimited ovoid mass (*) on a sub-tricuspid position; (C and D) mid-ventricular short-axis T1 and fat sat T2-weighted turbo spin-echo sequences, respectively, showing a hypointense homogeneous right ventricular mass (*) with no fat tissue; (E and F) mid-ventricular short-axis T1 post-contrast and phase-sensitive inversion recovery sequences, respectively, illustrating a small hyperintense core (arrowhead) inside the mass (*).

(0,23MB).

Cardiac magnetic resonance (CMR) allowed detailed tissue characterization. The mass was homogeneous and hypointense in both T1- (Figure 1C) and T2-weighted (Figure 1D) sequences, without fat tissue (Video 3). There was no detectable perfusion (Video 4) but a small core sign (Figure 1, arrowhead) was present on both T1 post-contrast (Figure 1E) and delayed enhancement (Figure 1F) acquisitions. No other abnormalities were noted, including pericardial or pleural effusions. In view of these findings, a benign cardiac mass was assumed. Repeated cardiac CMR at six and 12 months revealed similar findings.

Notwithstanding the previous clinical history, the CMR study excluded malignant primary or secondary etiologies for this mass, even suggesting an alternative process. During investigation, the patient confirmed the occurrence of a severe blunt chest trauma in a traffic accident 20 years before. Indeed, the non-specific tissue data were in accordance with an organized hematoma of the RV free wall. In this specific case, symptoms were attributed to COPD progression, as assessed by pulmonary function tests.

We found this case notable for the importance of CMR in the cardio-oncology setting. This tool provided biventricular functional assessment and excluded cardiac tumoral involvement, allowing confident risk stratification and conservative management. Furthermore, it led additional clinical investigation towards a definitive diagnosis of a very rarely reported cardiac condition.

Ethical disclosuresProtection of human and animal subjects

The authors declare that no experiments were performed on humans or animals for this study.

Confidentiality of data

The authors declare that they have followed the protocols of their work center on the publication of patient data.

Right to privacy and informed consent

The authors declare that no patient data appear in this article.

Conflicts of interest

The authors have no conflicts of interest to declare.

Appendix A
Supplementary material

(1,38MB)

Two-dimensional transthoracic echocardiography, modified short-axis view at the sub-tricuspid level, depicting a well defined right ventricular mass and part of the right coronary artery pathway along the atrioventricular groove.

(1,46MB)

Three-dimensional (3D) transthoracic echocardiography, live 3D bird's-eye view, modified 4-chamber view, showing a homogeneous and delimited ovoid mass in a sub-tricuspid position.

(53,14MB)

Steady-state free precession cine cardiac magnetic resonance sequences, modified long-axis 4-chamber and short-axis views, showing an apparently encapsulated mass along the right ventricular (RV) trabeculae. This mass is slightly hypointense compared with the ventricular cavity, and shows a synchronous movement with the RV free wall.

(45,15MB)

Magnetic resonance perfusion sequences, modified long-axis 4-chamber and short-axis views, with no signal gain along the mass.

Copyright © 2016. Sociedade Portuguesa de Cardiologia
Idiomas
Revista Portuguesa de Cardiologia
Opções de artigo
Ferramentas
Material Suplementar
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Ao assinalar que é «Profissional de Saúde», declara conhecer e aceitar que a responsável pelo tratamento dos dados pessoais dos utilizadores da página de internet da Revista Portuguesa de Cardiologia (RPC), é esta entidade, com sede no Campo Grande, n.º 28, 13.º, 1700-093 Lisboa, com os telefones 217 970 685 e 217 817 630, fax 217 931 095 e com o endereço de correio eletrónico revista@spc.pt. Declaro para todos os fins, que assumo inteira responsabilidade pela veracidade e exatidão da afirmação aqui fornecida.