Journal Information
Vol. 37. Issue 3.
Pages 269-270 (March 2018)
Share
Share
Download PDF
More article options
Vol. 37. Issue 3.
Pages 269-270 (March 2018)
Image in Cardiology
Open Access
Thrombus in left atrial appendage – Overcoming percutaneous closure limitations
Trombo no apêndice auricular esquerdo – transpondo limitações do encerramento percutâneo
Visits
4538
José Luís Martinsa,
Corresponding author
zeluismartins@gmail.com

Corresponding author.
, Luís Paivab, Marco Costab, Lino Gonçalvesb
a Centro Hospitalar Baixo Vouga, Aveiro, Portugal
b Centro Hospitalar Universitário Coimbra, Hospital Geral, Coimbra, Portugal
This item has received

Under a Creative Commons license
Article information
Full Text
Download PDF
Statistics
Figures (3)
Show moreShow less
Full Text

A 70-year-old male patient with a history of rheumatic mitral valve disease, who underwent percutaneous mitral balloon valvuloplasty (2004) and surgical mitral valve repair (2007) was referred for left atrial appendage (LAA) closure due to LAA thrombus persistence, despite adequate anticoagulation.

The LAA thrombus was documented in a transesophageal echocardiography (TEE) (Figure 1). This thrombus was formed despite long-term oral anticoagulation with warfarin. The first approach was to increase the anticoagulation therapeutic range (INR 3.0-4.0) for 3 months, followed by high-dose enoxaparin (1.5 mg/kg, every 12 h) with limited success.

Figure 1.

LAA thrombus (arrow) in 2D transesophageal echocardiography (TEE).

(0.1MB).

Due to high cardioembolic risk, the patient underwent successful LAA device implantation (Amulet™ St. Jude Medical; 28 mm) guided by intracardiac echocardiography (ICE), together with a cerebral protection system (Sentinel™, Claret Medical) (Figure 2). The patient received five days of unfractionated heparin prior to the procedure to reduce the “thrombotic burden”, resulting in partial reduction of the thrombus. Using ICE negated the need for sedation or intubation, thus permitting continuous monitoring and early management of acute neurologic complications.

Figure 2.

Device implantation using a cerebral protection system guided by intracardiac echocardiography (ICE).

(A) Fluoroscopy showing the cerebral protection system (Sentinel™, Claret Medical). (B) Transseptal puncture guided by ICE. (C) Fluoroscopy showing the device (Amulet™ St. Jude Medical; size 28 mm) implantation.

(0.26MB).

The procedure was performed without complications and no thrombotic material was retrieved from the cerebral protection system. The patient was discharged the following day on warfarin. The follow-up TEE at four weeks showed the device appropriately implanted (Figure 3).

Figure 3.

Follow-up TEE. Color Doppler 2D TEE (A) and 3D TEE (B) showing complete obliteration of LAA with no residual leak.

(0.23MB).

It is crucial to take into account strategies to prevent thrombus migration in these circumstances such as not injecting contrast directly into the LAA, performing the cannulation of the delivery system without guide or pigtail and using a cerebral protection system.

Conflicts of interest

The authors have no conflicts of interest to declare.

Copyright © 2017. Sociedade Portuguesa de Cardiologia
Idiomas
Revista Portuguesa de Cardiologia (English edition)
Article options
Tools
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

By checking that you are a health professional, you are stating that you are aware and accept that the Portuguese Journal of Cardiology (RPC) is the Data Controller that processes the personal information of users of its website, with its registered office at Campo Grande, n.º 28, 13.º, 1700-093 Lisbon, telephone 217 970 685 and 217 817 630, fax 217 931 095, and email revista@spc.pt. I declare for all purposes that the information provided herein is accurate and correct.